![Mitsubishi Electric MELSEC-L LD75D User Manual Download Page 383](http://html.mh-extra.com/html/mitsubishi-electric/melsec-l-ld75d/melsec-l-ld75d_user-manual_238753383.webp)
381
CHAPTER 9 MAJOR POSITIONING CONTROL
9
9.
2 Set
ting t
he Pos
itioning
D
at
a
9.2.7
2-axis fixed-feed control (interpolation)
In "2-axis fixed-feed control" ("[Da.2] Control system" = fixed-feed 2), two motors are used to carry out fixed-feed
control in a linear path while carrying out interpolation for the axis directions set in each axis.
In fixed-feed control, any remainder of the movement amount designated in the positioning data is rounded down if
less than that required for control accuracy to output the same amount of pulses.
(Refer to
Page 359, Section 9.1.6 for details on interpolation control.)
(1) Operation chart
In incremental system 2-axis fixed-feed control, the addresses ([Md.20] Current feed value) of the current stop
position (start addresses) of both axes are set to "0". Linear interpolation positioning is then carried out from that
position to a position at the end of the movement amount set in "[Da.6] Positioning address/movement amount".
The movement direction is determined by the sign of the movement amount.
(2) Restrictions
• The axis error "Continuous path control not possible" (error code: 516) will occur and the operation cannot
start if "continuous path control" is set in "[Da.1] Operation pattern". ("Continuous path control" cannot be set
in fixed-feed control.)
• If the movement amount of each axis exceeds "1073741824 (=2
30
)" when "0: Composite speed" is set in
"[Pr.20] Interpolation speed designation method", the error "Outside linear movement amount range" (error
code: 504) occurs at a positioning start and positioning cannot be started. (The maximum movement amount
that can be set in "[Da.6] Positioning address/movement amount" is "1073741824 (=2
30
)".)
• "Fixed-feed" cannot be set in "[Da.2] Control system" in the positioning data when "continuous path control"
has been set in "[Da.1] Operation pattern" of the immediately prior positioning data. (For example, if the
operation pattern of positioning data No. 1 is "continuous path control", fixed-feed control cannot be set in
positioning data No. 2.) The axis error "Continuous path control not possible" (error code: 516) will occur and
the machine will carry out a deceleration stop if this type of setting is carried out.
Designated movement
amount
Designated movement
amount
(0,0)
(0,0)
(0,0)
X axis
Y axis
" Md. 20 Current feed value" of each axis
is set to "0" at the positioning start
Summary of Contents for MELSEC-L LD75D
Page 2: ......
Page 11: ...9 Memo ...
Page 176: ...174 ...
Page 264: ...262 ...
Page 266: ...264 ...
Page 267: ...265 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 268: ...266 ...
Page 269: ...267 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 270: ...268 ...
Page 271: ...269 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 272: ...270 Z ABRST1 instruction execution ...
Page 273: ...271 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 278: ...276 ...
Page 279: ...277 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 280: ...278 ...
Page 281: ...279 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 282: ...280 ...
Page 283: ...281 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 284: ...282 ...
Page 285: ...283 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 286: ...284 ...
Page 287: ...285 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 316: ...314 Memo ...
Page 685: ...683 APPENDICES A Appendix 1 Function Update Appendix 1 1 Function comparison Memo ...
Page 738: ...736 Memo ...
Page 817: ......