![Mitsubishi Electric MELSEC iQ-R Series Programming Manual Download Page 1080](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r-series/melsec-iq-r-series_programming-manual_2378411080.webp)
1078
7 APPLICATION INSTRUCTIONS
7.29 Logging Instructions
Resetting trigger logging
LOGTRGR
This instruction resets the trigger condition of the specified logging setting number.
■
Execution condition
Setting data
■
Description, range, data type
■
Applicable devices
Processing details
• This instruction resets the LOGTRG instruction of the logging setting number specified by (s). The instruction disables the
LOGTRG instruction of the specified trigger logging setting number.
• The LOGTRGR instruction turns off the special relays (logging completion, logging trigger, and after logging trigger) with
the logging setting number in the device specified by (s).
• If the instruction is executed while buffer data is saved to an SD memory card, the execution of the instruction is made to
wait until all data is saved completely.
Operation error
Ladder
ST
ENO:=LOGTRGR(EN,s);
FBD/LD
Instruction
Execution condition
LOGTRGR
Operand
Description
Range
Data type
Data type (label)
(s)
Logging setting number
1 to 10
16-bit signed binary
ANY16
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
X, Y, M, L,
SM, F, B, SB,
FX, FY
J
\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U
\G
, J
\
,
U3E
\(H)G
Z
LT, LST,
LC
LZ
K,
H
E
$
(s)
Error code
(SD0)
Description
3405H
The value set to (s) is out of the range, 1 to 10.
RnCPU RnENCPU
RnSFCPU RnSFCPU
RnPCPU
RnPCPU
(Standard)
(Safety)
(Redundant)
(Process)
(s)
EN
ENO
s
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......