12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
469
12
[Cd.44] External input signal operation device
Set the external input signal status for the amplifier-less operation mode.
The setting of this area is applied from the buffer memory to the RD75 every 0.88ms.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0: OFF.
[Cd.49] All axes error reset
Clear the axis error detection, axis error No., axis warning detection, and axis warning No. for all the axes.
• Errors are cleared by setting 1: Reset axis errors for this area.
• After the error is reset, 0 is automatically stored. Storing 0 indicates the completion of the error reset.
• When the axis operation status is Error, this area clears the errors and sets the status of the RD75 to Standby again.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0.
[Cd.137] Amplifier-less operation mode switching request
Switch the operation mode.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0000H.
Setting item
Setting value
b0
Lower limit signal
0: OFF
1: ON
b1
Upper limit signal
b2
Drive unit READY signal
b3
Stop signal
b4
External command signal
b5
Zero signal
b6
Near-point dog signal
b7 to b15
Use prohibited
Set 0.
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.44] External input signal operation device
1928
1929
1930
1931
Buffer memory name
Common for Axis 1 to 4
[Cd.49] All axes error reset
1933
Amplifier-less operation mode switching request
Setting value
Switching from the normal operation mode to the amplifier-less operation
mode
ABCDH
Switching from the amplifier-less operation mode to the normal operation
mode
0000H
Buffer memory name
Common for Axis 1 to 4
[Cd.137] Amplifier-less operation mode switching request
1926
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......