12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
455
12
[Md.26] Axis operation status
This area stores the axis operation status. The following table shows the stored values.
■
Buffer memory address
The following table shows the buffer memory address of this area.
Axis operation status
Stored value
Step standby
-2
Error
-1
Standby
0
Stopped
1
Interpolation
2
JOG operation
3
Manual pulse generator operation
4
Analyzing
5
Special start standby
6
OPR
7
Position control
8
Speed control
9
Speed control in speed-position switching control
10
Position control in speed-position switching control
11
Position control in position-speed switching control
12
Speed control in position-speed switching control
13
Start time adjusting
14
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.26] Axis operation status
809
909
1009
1109
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......