12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
12.3
Basic Setting
Basic parameter 1
This section describes the details on the basic parameter 1.
[Pr.1] Unit setting
Set the command unit used for the positioning control. Select a unit from the following depending on the control target: mm,
inch, degree, or pulse. Different units can be set for each axis (axis 1 to 4).
When the unit setting is changed, the values of other parameters and positioning data will not be changed automatically. After
changing the unit, check if the parameter and data values are within the setting range. Set 2: degree to perform the speed-
position switching control (ABS mode).
■
Application examples of each unit
The units (mm, inch, degree, and pulse) are applicable to the following systems:
• mm or inch: XY table, conveyor (Select inch when the machine uses the inch as the unit.)
• degree: Rotating body (360 degrees/rotation)
• pulse: XY table, conveyor
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 3: pulse for all the axes.
Unit setting
Setting value
mm
0
inch
1
degree
2
pulse
3
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Pr.1] Unit setting
0
150
300
450
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......