5 MANUAL CONTROL
5.4 Manual Pulse Generator Operation
197
5
Operation procedure of the manual pulse generator operation
The manual pulse generator operation is performed in the following procedure.
• Mechanical elements such as limit switches are considered as already installed.
• Setting parameters is the common operation for all controls using the RD75.
STEP 1
Preparation
Control end
Set parameters.
(
Pr.1
to
Pr.24
STEP 2
STEP 3
STEP 5
STEP 6
Manual pulse
generator
operation Start
Manual pulse
generator
operation
monitoring
Manual pulse
generator
operation end
Create a program to set Cd.20 Manual pulse
generator 1 pulse input magnification. (control data
setting)
Create a program to set whether to enable or disable
the manual pulse generator operation. (setting of
Cd.21 Manual pulse generator enable flag)
Write the programs created on STEP 1 and STEP 2
to the CPU module.
Issue a command to enable the manual pulse
generator operation, and input the signals
from the manual pulse generator.
Monitor the manual pulse generator operation.
End the input from the manual pulse generator,
and issue a command to disable the manual pulse
generator operation.
One of the following two methods can be used.
Method 1
Directly set (write) the parameters to the RD75
using an engineering tool.
Method 2
Set (write) the parameters from the CPU module
to the RD75 using the program (TO instruction).
:
:
Write "1" in Cd.21 Manual pulse generator enable flag,
and operate the manual pulse generator.
Monitor using an engineering tool.
Stop operating the manual pulse generator, and write
"0" in Cd.21 Manual pulse generator enable flag.
)
STEP 4
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......