5 MANUAL CONTROL
5.2 JOG Operation
179
5
Parameters required for the JOG operation
To perform the JOG operation, parameters must be set. The following table shows the required parameters for performing the
JOG operation. When only the JOG operation is performed, parameters not described below are not required. (Set the value
within the setting range, such as the initial value.)
: Always set
: Set as required (set a value within the setting range such as the initial value when the item is not used.)
For details on the settings, refer to the following.
Page 346 DATA USED FOR POSITIONING CONTROL
• Setting parameters is the common operation for all controls using the RD75. When performing another
control (Major positioning control, Advanced positioning control, or OPR control), configure the setting items
required for the control.
• Parameters are set for each axis.
Setting item
Setting
requirement
Parameter
[Pr.1]
Unit setting
[Pr.2]
No. of pulses per rotation (Ap) (Unit: pulse)
[Pr.3]
Movement amount per rotation (Al) (Unit: pulse)
[Pr.4]
Unit magnification (Am)
[Pr.5]
Pulse output mode
[Pr.6]
Rotation direction setting
[Pr.7]
Bias speed at start (Unit: pulse/s)
[Pr.8]
Speed limit value (Unit: pulse/s)
[Pr.9]
Acceleration time 0 (Unit: ms)
[Pr.10]
Deceleration time 0 (Unit: ms)
[Pr.11]
Backlash compensation amount (Unit: pulse)
[Pr.12]
Software stroke limit upper limit value (Unit: pulse)
[Pr.13]
Software stroke limit lower limit value (Unit: pulse)
[Pr.14]
Software stroke limit selection
[Pr.15]
Software stroke limit valid/invalid setting
[Pr.17]
Torque limit setting value (Unit: %)
[Pr.23]
Output signal logic selection
[Pr.25]
Acceleration time 1 (Unit: ms)
[Pr.26]
Acceleration time 2 (Unit: ms)
[Pr.27]
Acceleration time 3 (Unit: ms)
[Pr.28]
Deceleration time 1 (Unit: ms)
[Pr.29]
Deceleration time 2 (Unit: ms)
[Pr.30]
Deceleration time 3 (Unit: ms)
[Pr.31]
JOG speed limit value (Unit: pulse/s)
[Pr.32]
JOG operation acceleration time selection
[Pr.33]
JOG operation deceleration time selection
[Pr.34]
Acceleration/deceleration processing selection
[Pr.35]
S-curve ratio (Unit: %)
[Pr.36]
Sudden stop deceleration time (Unit: ms)
[Pr.37]
Stop group 1 sudden stop selection
[Pr.38]
Stop group 2 sudden stop selection
[Pr.39]
Stop group 3 sudden stop selection
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......