6
FAN
VANE
HEAT
MODE
ECONO COOL
STOP
START
HR.
MIN
I FEEL COOL
DRY
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
I FEEL COOL
DRY
AM
PM
CLOCK
˚C
AMPM
HEAT
RESET CLOCK
“I FEEL...” AUTO OPERATION
With the “
(I FEEL...)” auto operation mode, the
optimum room condition can be set automatically
with a one-touch operation.
To start operation:
■
Press the
ON/OFF
button.
When the
“
(I FEEL...)
”
mode is selected, the air
conditioner is automatically controlled at the optimum
temperature.
To stop operation:
■
Press the
ON/OFF
button.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
If you feel slightly warm,
■
Press the
TOO
WARM
button to lower the tem-
perature.
One press lowers the temperature by about 1°C.
If you feel slightly cool,
■
Press the
TOO
COOL
button to raise the tem-
perature.
One press raises the temperature by about 1°C.
When “
(I FEEL...)” is not selected, press the
MODE
button until it is set.
Each time the button is pressed, the operation mode is
changed in sequence :
(I FEEL...)
→
(COOL)
→
(DRY)
→
(HEAT)
Description of “I FEEL...” mode
Operation state
This shows that the air condi-
tioner is operating to reach the
target temperature. Wait until
the target temperature is ob-
tained.
This shows that the room tem-
perature is approaching the
target temperature.
(In case of outdoor unit MXZ
series only)
Please refer to INFORMATION
FOR MULTI SYSTEM AIR
CONDITIONER (page 7). *
Indica-
tion
Difference between
target temperature
and room
temperature
About 2°C or
more
About 2°C or
less
—
Details of operation
According to the room temperature when the operation
starts, the operation mode is automatically set to COOL,
DRY or HEAT. However, when operation is started again
within 2 hours after it is stopped, the same operation mode
before the operation is stopped is selected. The operation
mode selected first is not changed even if the room tem-
perature changes. If the operation mode does not match
the room condition, select the appropriate operation mode
by pressing the
MODE
button.
Details of auto operation
Note:
When both Operation Indicator lamps are lighting, as
the air conditioner is operating to reach the target tem-
perature, the set temperature may not be changed. In
this case, please wait until the lighting of Operation In-
dicator lamp changes from two to only one and then
change the set temperature.
Room temperature
when started
About 25°C or higher
About 25°C to 23°C
About 23°C or lower
Operation mode
COOL
DRY
HEAT
Target temperature
(initial state)
About 24°C
—
About 26°C
Details of display on the indoor unit
The Operation Indicator lamps at the right side of the in-
door unit indicate the operation state.
Operation Indicator lamp
Operation Indicator
Description of “AUTO RESTART FUNCTION”
• These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller just before the shutoff of the main
power.
• If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.
• If the unit was in the emergency operation before the shutoff of the main power, it will start operation, at main power on,
in the same mode as the one set with the remote controller before the emergency operation.
• If the unit is operated in “I FEEL...” mode before power failure, the operation is not memorized. In “I FEEL...” mode, the
operation is decided by the initial room temperature at (re)start.
Lighting
Blinking *
Not lighting
* Except MCFH-24NV