13

GB

System block  

Certain blocks are reserved for special purpo-
ses: 

0

Main menu 

990

Reserved for compatibility with
other terminals 

991

Time channels

992-999

Reserved for compatibility with
other terminals

Mac10eng  Seite 13  Freitag, 5. Februar 1999  3:29 15

Summary of Contents for MAC 10

Page 1: ...MAC Operator Terminal Human Machine Interface Installation Manual MAC 10 MAC 12 MITSUBISHI ELECTRIC MITSUBISHI ELECTRIC EUROPE B V FACTORY AUTOMATION ...

Page 2: ...at many application areas for this equipment the user himself must acquire the appropriate knowledge needed to use the equipment correctly for particular applications Mitsubishi Electric Europe B V absolves itself of all responsibilities for damage and injuries that may occur during installation or use of this equipment Mitsubishi Electric Europe B V absolves itself of all responsibilities for any...

Page 3: ... operated by qualified personnel At installation The product is constructed for stationary installation Install the product according to the accompa nying installation instructions The product must be grounded according to the accompanying installation instructions This equipment must be installed by quali fied personnel High voltage signal and supply cables must be separated The product should no...

Page 4: ... mild detergent Repairs should be made by qualified person nel At disassembly and scrapping Local regulations apply concerning recyc ling of products or part Please note that the lithium battery electro lyte condenser and display contain hazardous substances Mac10eng Seite 3 Freitag 5 Februar 1999 3 29 15 ...

Page 5: ...a family of terminals developed to satisfy the demands made for man machine communication The functions built into the terminal include among other things the possibility to display text with dynamic indication maneuvring objects and time channel control MAC 12 MTA 12 also include function for datalogging and recipes A terminal is programmed from a PC with the PC software The programmed project is...

Page 6: ...he signals in the PLC system There are 7 types of dynamic object digital analog jump date time bar graph multiple choice object and text object Time channels Time channels make it possible to set a digital signal ON or OFF controlled by the real time clock that is to enable you to ensure that a cer tain function is ON during certain periods of the day Data logging recipes Only valid for MAC 12 MTA...

Page 7: ...able is straight the contact at each end is compatible with both the terminal and the PLC system The cable has a maximum length of 3 m and the communication speed is 9600 baud The terminal is powered by the PLC system via the cable supplied If a longer cable is required the terminal must be powered from a source other than the PLC system MITSUBISHI MEL SEC FX0 Mac10eng Seite 6 Freitag 5 Februar 19...

Page 8: ...Connection to a personal computer The terminal is connected to a personal compu ter using a SC06N adapter The maximum cable length is 3 meter and the communication speed is 9600 baud Programming from personal computer You program the terminal with the PC software installed on a personal computer The terminal will enter the Communication with MP mode if you keep the keys pressed during ter minal po...

Page 9: ...rable analog object Execute jump Select execute choice from a multiple choice object Reset manoeuvrable digital object OFF Decreace value of manoeuvrable analog object Move up one line If the first line of time channel settings return to previous level Move to next field position Move to previous field position Move down one line Mac10eng Seite 8 Freitag 5 Februar 1999 3 29 15 ...

Page 10: ...s are necessary Choice of PLC system You must choose to which PLC system the ter minal is to be connected Select New in the menu File In the dialogue box Project settings you select PLC system and type of terminal Choice of character set and menu language The majority of languages have letters which are specific to that language Various menu lan guages can be chosen Select Country settings in the ...

Page 11: ...l now be displayed Select New to create a textblock Now the Block hea der is displayed In this example we shall define a textblock 1 Enter the number of the block here in this case 0 2 Click on the button Status 3 Mark the alternative Put cursor at first man object 4 Press OK 5 Press OK to begin editing the block A field will be shown 6 Select Digital text in the Object menu 7 First enter which I ...

Page 12: ...is example ON 10 Press OK to close the dialog box The dyna mic object is now shown by and two on the screen When the program is ready you can connect the terminal to the PLC system Mac10eng Seite 11 Freitag 5 Februar 1999 3 29 15 ...

Page 13: ... possible see User s manual for the terminal Dynamic objects The following dynamic text objects can be used in block and linked to the stated types of signals Digital Digital object 2 states Analog Analog object as value Bar graph Porportional filling of analog object Multichoice Digital object 8 states Text Text strings from PLC Jump Jump to block Date time Date and or time Mac10eng Seite 12 Frei...

Page 14: ...blocks are reserved for special purpo ses 0 Main menu 990 Reserved for compatibility with other terminals 991 Time channels 992 999 Reserved for compatibility with other terminals Mac10eng Seite 13 Freitag 5 Februar 1999 3 29 15 ...

Page 15: ...de printing Container material Black varnished steel Weight 230 g PLC system connection 8 pol Mini DIN contact Cable to PLC system 4 pair cable shielded Display MAC 10 MTA 10 LCD display liquid crystal Supertwist 1 lines of 16 characters each 8 mm character height The contrast adjustable with potentiometer inside MAC 12 MTA 12 LCD display liquid crystal Supertwist 2 lines of 16 characters each 5 m...

Page 16: ... condensation Interference test Interference tested for external noise according to EN 50081 1 emission and EN 50082 2 immunity The product have passed and comply with spe cifications of the above tests The product must only be used for applications covered by these standards EMC tests on the terminal G L Beijer Electronics AB confirm that the terminals conforms with the essential protection requi...

Page 17: ...16 GB Mac10eng Seite 16 Freitag 5 Februar 1999 3 29 15 ...

Page 18: ...A 1 Cadbild fm Seite 1 Freitag 5 Februar 1999 4 45 16 ...

Page 19: ...A 2 Cadbild fm Seite 2 Freitag 5 Februar 1999 4 45 16 ...

Page 20: ...A 3 Cadbild fm Seite 3 Freitag 5 Februar 1999 4 45 16 ...

Page 21: ...A 4 Cadbild fm Seite 4 Freitag 5 Februar 1999 4 45 16 ...

Page 22: ...A 5 Cadbild fm Seite 5 Freitag 5 Februar 1999 4 45 16 ...

Page 23: ...A 6 Cadbild fm Seite 6 Freitag 5 Februar 1999 4 45 16 ...

Page 24: ...A 7 Cadbild fm Seite 7 Freitag 5 Februar 1999 4 45 16 ...

Page 25: ...A 8 Cadbild fm Seite 8 Freitag 5 Februar 1999 4 45 16 ...

Page 26: ...MITSUBISHI ELECTRIC MITSUBISHI ELECTRIC EUROPE B V FACTORY AUTOMATION GOTHAER STR 8 D 40880 RATINGEN TEL 0 21 02 4 86 10 FAX 0 21 02 4 86 1 12 ...

Reviews: