Installation and operation manual 

KSGD02 Revision: 1.4 

Page 4 of 16 

R

KSGD-01WS-B 

!

!

Safety Precautions 

 

 

 

Definition of symbols 

 

Alert 

Symbol 

Description 

Danger 

!

 

Will result in death or serious injury if not avoided.  

Warning 

!

 

Could potentially result in death of serious injury if not avoided.  

Caution 

!

 

Could  potentially  result  in  damage  to  the  product,  injury  or  damage  to  the 
environment if not avoided. 

Information 

i

 

Information notes relating to the operation of the product. 

 
    

Warning:  

 
Carefully read the labels affixed to the main unit. 

 

Warning: 

 

Ask the dealer or an authorised technician to install the unit.  

 

 

Improper installation by the user may result in water leakage, electric shock, or fire.  

 

 

Use the specified cables for wiring. Make the connections securely so that any outside forces acting on the cables 
are not applied to the terminals. Inadequate connection and fastening may generate heat and cause a fire.  

 

 

Never repair the unit. If the controller must be repaired, consult the dealer.  
If the unit is repaired improperly, electric shock, or fire may result.  

 

 

When handling this product, always wear protective equipment. EG: Gloves, full arm protection namely boiler suit, 
and safety glasses.  
Improper handling may result in injury.  

 

 

If refrigerant gas leaks during installation work, ventilate the room.  
If the refrigerant gas comes into contact with a flame, poisonous gases will be released.  

 

 

Install the controller according to this Installation Manual. 
If the unit is installed improperly, electric shock, or fire may result.  
Have all electric work done by a licensed electrician according to "Electric Facility Engineering Standard", "Interior 
Wire Regulations" and the instructions given in this manual and always use a special circuit.  

 

 

If the power source capacity is inadequate or electric work is performed improperly, electric shock and fire may 
result.  
Keep the electric parts away from any water - 

 

Contact may result in electric shock, fire or smoke.  

 

 

After completing installation work, make sure that refrigerant gas is not leaking.  
If the refrigerant gas leaks and is exposed to a fan heater, stove, oven, or other heat source, it may generate noxious 
gases.  

 

 

Do not reconstruct or change the settings of the protection devices. If the pressure switch, thermal switch, or other 
protection device is shorted or operated forcibly, or parts other than those specified by Mitsubishi Electric are used, 
fire or explosion may result.  

 
To dispose of this product, consult your dealer. Do not use a leak detection additive. 

 

 

Summary of Contents for k-con KSGD-01WS-B

Page 1: ...Installation and operation manual KSGD02 Revision 1 4 Page 1 of 16 R KSGD 01WS B Refrigerant leak detector Installation and operation manual Version 1 4 Manufactured for MITSUBISHI ELECTRIC UK ...

Page 2: ...In no event will the manufacturer be liable for any direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages In the interest of continued product development the manufacturer reserves the right to make improvements to this manual and the products described herein at any time without notice or...

Page 3: ...erview 7 1 1 Specification Overview 7 2 Installation 8 2 1 Locating the sensor 8 2 2 Electrical connections 9 2 3 Other features 10 3 Operation 11 3 1 Operational matrix 11 4 Testing 12 4 1 Measuring the Gv 12 4 1 Bump test procedure 12 4 2 Full Operational test procedure 13 5 Fault finding 14 Revisions 15 Notes 16 ...

Page 4: ...namely boiler suit and safety glasses Improper handling may result in injury If refrigerant gas leaks during installation work ventilate the room If the refrigerant gas comes into contact with a flame poisonous gases will be released Install the controller according to this Installation Manual If the unit is installed improperly electric shock or fire may result Have all electric work done by a li...

Page 5: ... flares and flange connections The refrigerator oil will degrade if it is mixed with a large amount of mineral oil Use liquid refrigerant to fill the system If gas refrigerant is used to seal the system the composition of the refrigerant in the cylinder will change and performance may drop Do not use a refrigerant other than what is specified If the incorrect refrigerant R22 etc is used the chlori...

Page 6: ... packaging bags so that children will not play with them If children play with a plastic bag which has not been torn apart they face the risk of suffocation Before starting a test run Caution Do not touch the switches with wet fingers Touching a switch with wet fingers can cause electric shock Do not touch the refrigerant pipes during and immediately after operation During and immediately after op...

Page 7: ...ntinued product development the manufacturer reserves the right to make improvements to products with notice or obligation Housing White plastic OR Stainless steel fascia back box dry lining box supplied on request other options available Power 12 24V AC or DC Power usage Max 2 5VA 1VA nominal Relays 1 or 2 Contact rating 0 5A 125VAC 1A 24VDC Indicators 1 x Tri colour LED Sounder 85dB 2300Hz 300Hz...

Page 8: ... conditioning unit 2 Accessible for maintenance The KSGD should be mounted in a position where it can be easily accessed for maintenance and repairs 3 Minimize possibility of damage Mount the sensor in a position that minimizes the risk of mechanical damage to the unit 4 Minimize false alarms Semi conductor sensors can be poisoned exposure may take considerable time to recover Solvent paints and s...

Page 9: ...AC or DC 2 Power V2 3 Relay 1 NO1 Normally Open 4 Relay 1 C1 Common 5 Relay 2 NC2 Normally Closed 6 Relay 2 C2 Common Single relay version See section 3 for details on the relay operation and functions Relay s are energized in normal operation the relay will de energize if an alarm or fault occurs or if power is not present The tables above show the relay s in the de energized power removed state ...

Page 10: ... as the sensor and buzzer enable link are located on the front of the detector PCB When the buzzer enable disable link is fitted the buzzer will operate when required Remove this link to disable the buzzer permanently i Status LED Buzzer Buzzer Enable Disable link Sensor Factory use only Fig 2 4 KSGD other features ...

Page 11: ...EN Normal operation 3 4 5 6 3 4 4 5 Constant GREEN OFF 0 4 1VDC CLOSED OPEN CLOSED OPEN Sensor fault 3 4 5 6 3 4 4 5 RED OFF 1Hz 1 x AMBER FLASH PER MINUTE Pulses once per minute 0 1VDC OPEN CLOSED OPEN CLOSED As the gas concentration increases Pre alarm Level 1 Reading 500ppm For 2 seconds 3 4 5 6 3 4 4 5 Flashing GREEN OFF 2Hz OFF 2 5VDC CLOSED OPEN CLOSED OPEN Pre alarm Level 2 Reading 1000ppm ...

Page 12: ...ntaminant and the voltage should subside Operating State Dual Relay version Connection terminal states Single Relay version Connection terminal states LED Buzzer Gv Voltage Normal operation 3 4 5 6 3 4 4 5 Constant GREEN OFF 0 4 1VDC CLOSED OPEN CLOSED OPEN 2 Using a small amount of butane or equivalent spray gas at the sensor for approximately 30 to 40 seconds 3 The sensor will enter the High Lev...

Page 13: ...1 to 2 minutes Operating State Dual Relay version Connection terminal states Single Relay version Connection terminal states LED Buzzer Gv Voltage Normal operation 3 4 5 6 3 4 4 5 Constant GREEN OFF 0 4 1VDC CLOSED OPEN CLOSED OPEN 3 Place the plastic tube directly over the perforation on the cover plate and turn the regulator valve fully anticlockwise to release the test gas Apply test gas onto t...

Page 14: ...ypically less than 5 minutes It is recommended that the sensor is not subjected to test gas for a prolonged period 3 minutes as recovery may become significantly longer Please ensure the regulator is switched off after use and the bottle is stored in a ventilated space See section 3 1 for supplementary information of Gv voltages at different operational states The detectors relays are normally ene...

Page 15: ...Installation and operation manual KSGD02 Revision 1 4 Page 15 of 16 R KSGD 01WS B Revisions 1 4 11 12 2019 First released version KR ...

Page 16: ...Installation and operation manual KSGD02 Revision 1 4 Page 16 of 16 R KSGD 01WS B Notes ...

Reviews: