ALARMS
The table below shows the possible alarms for i-BX(N) units with Nadisystem sw.
The alarms affecting the Power+ inverter are shown with a grey background.
Alarm code
Description
Remarks
A001
B1 probe alarm
A002
B2 probe alarm
A003
B3 probe alarm
A004
B4 probe alarm
A005
B5 probe alarm
A006
B6 probe alarm
A007
B7 probe alarm
A008
B8 probe alarm
A009
B9 probe alarm
A010
B10 probe alarm
A011
B11 probe alarm
A012
B12 probe alarm
A013
High pressure from DIN
A014
High compressor pressure from transducer
A015
Low compressor pressure from transducer
A020
Compressor 1 thermal switch or inverter alarm
A023
Geothermal well side flow switch
A025
System side water flow switch
A030
Compressor 1 hours of operation threshold reached
A033
Primary pump hours of operation threshold reached
A035
Mixed circuit pump hours of operation threshold reached
A036
Coil fan hours of operation threshold reached
A038
System exchanger antifreeze
A039
Mixed circuit maximum temperature threshold reached
A040
Mixed circuit minimum temperature threshold reached
A041
High DHW temperature threshold reached
A042
Internal ambient antifreeze
Indication of the antifreeze zones on the mask
A047
EVO probe alarm
Indication of the probes in alarm on the mask
A048
Low overheating alarm
A049
Low evaporation temperature alarm (LOP)
A050
High evaporation temperature alarm (MOP)
A051
High condensation temperature alarm
A052
EEPROM alarm
A053
Low suction temperature alarm
A054
Anti-legionellosis alarm
A055
Th-Tune 1: Temperature probe faulty
A056
Th-Tune 1: Device offline
A094
Defrost disabled due to maximum time reached
A095
Th-Tune 2: Temperature probe faulty
A096
Th-Tune 2: Device offline
A109
Low compressor pressure from pressure switch
A116
pLAN: Master unit #1 not connected
A117
pLAN: Slave unit #2 not connected
A118
pLAN: Slave unit #3 not connected
A119
pLAN: Slave unit #4 not connected
A124
Th-Tune 1: Humidity probe faulty
A125
Th-Tune 2: Humidity probe faulty
A130
Master #1 alarm
A131
Slave #2 alarm
A132
Slave #3 alarm
A133
Slave #4 alarm
A134
Compressor start failed
Relating to the Power+ inverter
The cause of the alarm is the failed compressor start due to the failing
to generate a pressure delta after the powering of the compressor.
Alarm and semi-automatic reset. After an n. number of unsuccessful
startup attempts, the alarm becomes manual.
A135
Out of envelope alarm
Relating to the Power+ inverter
A136
High discharge gas temperature alarm
Relating to the Power+ inverter
The cause of the alarm is the exceeding of the maximum discharge
temperature threshold as read by probe B11.
A137
Low pressure differential alarm
Relating to the Power+ inverter
The cause of the alarm is the lack of a minimum pressure delta
between delivery and suction (this varies based on compressor
model). This delta must be guaranteed both during startup and during
normal operation.
A138
Inverter type not compatible
Relating to the Power+ inverter (notification only, no logging)