background image

GT16 General Description

Thank you for purchasing the GOT1000 Series.

GT1695M-XTBA
GT1675M-STBA
GT1675-VNBA
GT1665M-STBA
GT1662-VNBA

GT1695M-XTBD
GT1675M-STBD
GT1675-VNBD
GT1665M-STBD
GT1662-VNBD

GT1685M-STBA
GT1675M-VTBA
GT1672-VNBA
GT1665M-VTBA
GT1655-VTBD

GT1685M-STBD
GT1675M-VTBD
GT1672-VNBD
GT1665M-VTBD

Prior to use, please read both this manual and the 
detailed manual thoroughly to fully understand the 
product.

MODEL

GT16-U-GD-E

Model 

code

1D7MP6

IB(NA)-0800544ENG-A(1410)MEE

1

2

3

4

5

6

7

8

9

0

1

2

3

4

5

6

7

8

9

0

SAFETY PRECAUTIONS

(Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "WARNING"
and "CAUTION".

Note that the 

CAUTION level may lead to a serious accident 

according to the circumstances.
Always follow the instructions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and 
always forward it to the end user.

[DESIGN PRECAUTIONS]

Indicates that incorrect handling may cause 
hazardous conditions, resulting in death or 
severe injury.

Indicates that incorrect handling may cause 
hazardous conditions, resulting in medium or 
slight personal injury or physical damage.

Some failures of the GOT, communication unit or cable may keep the outputs 

on or off.

Some failures of a touch panel may cause malfunction of the input objects 

such as a touch switch.

An external monitoring circuit should be provided to check for output signals 

which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

If a communication fault (including cable disconnection) occurs during 

monitoring on the GOT, communication between the GOT and PLC CPU is 

suspended and the GOT becomes inoperative.

For bus connection : The CPU becomes faulty and the GOT becomes 

inoperative.

For other than bus connection : The GOT becomes inoperative.

A system where the GOT is used should be configured to perform any 

significant operation to the system by using the switches of a device other 

than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

Do not use the GOT as the warning device that may cause a serious 

accident.

An independent and redundant hardware or mechanical interlock is required 

to configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect 

output or malfunction.

  

WARNING

     CAUTION

    

WARNING

[DESIGN PRECAUTIONS]

[DESIGN PRECAUTIONS]

[MOUNTING PRECAUTIONS]

Incorrect operation of the touch switch(s) may lead to a serious accident if the 

GOT backlight is gone out.

When the GOT backlight goes out, although the POWER LED blinks (green/

orange) and the display section dims, the input of the touch switch(s) remains 

active.

This may confuse an operator in thinking that the GOT is in "screensaver" 

mode, who then tries to release the GOT from this mode by touching the 

display section, which may cause a touch switch to operate.

Note that the following occurs on the GOT when the backlight goes out.

•  GT1655-V: The POWER LED blinks (green/orange) and the monitor screen 

appears blank.

•  Models other than GT1655-V: The POWER LED blinks (green/orange) and 

the monitor screen

 

appears dimmed.

The display section of the GT16 is an analog-resistive type touch panel.

If you touch the display section simultaneously in 2 points or more, the switch 

that is located around the center of the touched point, if any, may operate.

Do not touch the display section in 2 points or more simultaneously.

Doing so may cause an accident due to incorrect output or malfunction.

When programs or parameters of the controller (such as a PLC) that is 

monitored by the GOT are changed, be sure to reset the GOT or shut off the 

power of the GOT at the same time.

Not doing so can cause an accident due to false output or malfunction.

Do not bundle the control and communication cables with main-circuit, power 

or other wiring.

Run the above cables separately from such wiring and keep them a minimum 

of 100mm apart.

Not doing so noise can cause a malfunction.

Do not press the GOT display section with a pointed material as a pen or 

driver.

Doing so can result in a damage or failure of the display section.

When the GOT is connected to the Ethernet network, the available IP 

address is restricted according to the system configuration.

• When multiple GOTs are connected to the Ethernet network:

  Do not set the IP address (192.168.0.18) for the GOTs and the controllers in

   the network.

• When a single GOT is connected to the Ethernet network:

  Do not set the IP address (192.168.0.18) for the controllers except the GOT

   in the network.

Doing so can cause the IP address duplication. The duplication can 

negatively affect the communication of the device with the IP address 

(192.168.0.18).

The operation at the IP address duplication depends on the devices and the 

system.

Turn on the controllers and the network devices to be ready for

 communication before they communicate with the GOT.

 Failure to do so can cause a communication error on the GOT.

Be sure to shut off all phases of the external power supply used by the 

system before mounting or removing the GOT main unit to/from the panel.

Not doing so can cause the unit to fail or malfunction.

Be sure to shut off all phases of the external power supply used by the 

system before mounting or removing the communication unit, option function 

board onto/from the GOT.

Not doing so can cause the unit to fail or malfunction.

When installing the option function board, wear an earth band etc. to avoid 

the static electricity.

Not doing so can cause a unit corruption.

Use the GOT in the environment that satisfies the general specifications 

described in this manual.

Not doing so can cause an electric shock, fire, malfunction or product 

damage or deterioration.

When mounting the GOT to the control panel, tighten the mounting screws in 

the specified torque range (0.36 to 0.48 N•m) with a Phillips-head screwdriver 

No.2.

Undertightening can cause the GOT to drop, short circuit or malfunction.

Overtightening can cause a drop, short circuit or malfunction due to the 

damage of the screws or the GOT.

When loading the communication unit to the GOT, fit it to the connection 

interface of the GOT and tighten the mounting screws in the specified torque 

range (0.36 to 0.48 N•m) with a Phillips-head screwdriver No.2.

Under tightening can cause the GOT to drop, short circuit or malfunction. 

Overtightening can cause a drop, failure or malfunction due to the damage of 

the screws or unit.

When mounting the option function board onto the GOT, connect it to the 

corresponding connector securely and tighten the mounting screws within the 

specified torque range (0.25 to 0.35 N•m) with a Phillips-head screwdriver 

No.1.

Undertightening can cause malfunction due to poor contact.

Overtightening can cause malfunction due to screw or unit damage.

When inserting a CF card into the GOT, push it into the insertion slot until the 

CF card eject button will pop out.

If not properly inserted, a bad connection may cause a malfunction.

When inserting/removing a CF card into/from the GOT, turn the CF card 

access switch off in advance.

Failure to do so may corrupt data within the CF card.

When removing a CF card from the GOT, make sure to support the CF card 

by hand, as it may pop out.

Failure to do so may cause the CF card to drop from the GOT and break.

WARNING

CAUTION

WARNING

CAUTION

[MOUNTING PRECAUTIONS]

[WIRING PRECAUTIONS]

[TEST OPERATION PRECAUTIONS]

[STARTUP/MAINTENANCE PRECAUTIONS]

When installing a USB memory to the GOT, make sure to install the USB 

memory to the USB interface firmly.

Failure to do so may cause a malfunction due to poor contact.

Before removing the USB memory from the GOT, operate the utility screen 

for removal. After the successful completion dialog box is displayed, remove 

the memory by hand carefully.

Failure to do so may cause the USB memory to drop, resulting in a damage 

or failure of the memory.

For closing the USB environmental protection cover, fix the cover by pushing 

the 

 mark on the latch firmly to comply with the protective structure.

Remove the protective film of the GOT.

When the user continues using the GOT with the protective film, the film may 

not be removed.

Operate and store the GOT in environments without direct sunlight, high 

temperature, dust, humidity, and vibrations.

When using the GOT in the environment of oil or chemicals, use the 

protective cover for oil.

Failure to do so may cause failure or malfunction due to the oil or chemical 

entering into the GOT.

Be sure to shut off all phases of the external power supply used by the 

system before wiring.

Failure to do so may result in an electric shock, product damage or 

malfunctions.

Always ground the FG terminal, LG terminal, and Functional ground terminal 

of the GOT power to the protective ground conductors dedicated to the GOT.

Not doing so may cause an electric shock or malfunction.

When tightening the terminal screws, use a Phillips-head screwdriver No.2. 

Terminal screws which are not to be used must be tightened always at torque 

0.5 to 0.8 N•m.

Otherwise there will be a danger of short circuit against the solderless 

terminals.

Use applicable solderless terminals and tighten them with the specified 

torque. 

If any solderless spade terminal is used, it may be disconnected when the 

terminal screw comes loose, resulting in failure. 

Correctly wire the GOT power supply section after confirming the rated 

voltage and terminal arrangement of the product.

Not doing so can cause a fire or failure.

Tighten the terminal screws of the GOT power supply section in the specified 

torque range (0.5 to 0.8 N•m). Undertightening can cause a short circuit or 

malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of 

the screws or the GOT.

Exercise care to avoid foreign matter such as chips and wire offcuts entering 

the GOT. Not doing so can cause a fire, failure or malfunction.

The module has an ingress prevention label on its top to prevent foreign 

matter, such as wire offcuts, from entering the module during wiring.

Do not peel this label during wiring.

Before starting system operation, be sure to peel this label because of heat 

dissipation. 

Plug the communication cable into the connector of the connected unit and 

tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of 

the screws or unit.

Plug the QnA/ACPU/Motion controller(A series) bus connection cable by 

inserting it into the connector of the connected unit until it "clicks".

After plugging, check that it has been inserted snugly.

Not doing so can cause a malfunction due to a contact fault.

Before performing the test operations of the user creation monitor screen 

(such as turning ON or OFF bit device, changing the word device current 

value, changing the settings or current values of the timer or counter, and 

changing the buffer memory current value), read through the manual 

carefully and make yourself familiar with the operation method.

During test operation, never change the data of the devices which are used to 

perform significant operation for the system.

False output or malfunction can cause an accident.

When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

Correctly connect the battery connector.

Do not perform the following actions to the battery.

 • Charging, disassembling, heating, short-circuiting, or soldering the battery, 

    or throwing it into the fire

Doing so will cause the battery to produce heat, explode, or ignite, resulting in 

injury and fire.

Before starting cleaning or terminal screw retightening, always switch off the 

power externally in all phases.

Not switching the power off in all phases can cause a unit failure or 

malfunction.

Undertightening can cause a short circuit or malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of 

the screws or unit.

CAUTION

WARNING

CAUTION

WARNING

WARNING

[STARTUP/MAINTENANCE PRECAUTIONS]

[TOUCH PANEL PRECAUTIONS]

[BACKLIGHT CHANGING PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION PRECAUTIONS]

Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling, 

motion or accidental pulling of the cables or can cause a malfunction due to a 

cable connection fault.

When unplugging the cable connected to the unit, do not hold and pull the 

cable portion.

Doing so can cause the unit or cable to be damaged or can cause a 

malfunction due to a cable connection fault.

Do not drop the module or subject it to strong shock. A module damage may 

result.

Do not drop or give an impact to the battery mounted to the unit.

Doing so may damage the battery, causing the battery fluid to leak inside the 

battery.

If the battery is dropped or given an impact, dispose of it without using.

Before touching the unit, always touch grounded metals, etc. to discharge 

static electricity from human body, etc.

Not doing so can cause the unit to fail or malfunction.

Replace battery with GT15-BAT or GT11-50BAT by Mitsubishi electric 

Co.only.

Use of another battery may present a risk of fire or explosion.

Dispose of used battery promptly. 

Keep away from children.Do not disassemble and do not dispose of in fire.

For the analog-resistive film type touch panels, normally the adjustment is not 

required.

However, the difference between a touched position and the object position 

may occur as the period of use elapses. When any difference between a 

touched position and the object position occurs,execute the touch panel 

calibration.

When any difference between a touched position and the object position 

occurs, other object may be activated. This may cause an unexpected 

operation due to incorrect output or malfunction.

Before changing the backlight, always switch off the GOT power externally in 

all phases (when the GOT is connected to the bus, the PLC CPU power must 

also be switched off externally in all phases) and remove the GOT from the 

control panel.

Not switching the power off in all phases may cause an electric shock.

Not removing the unit from the control panel can cause injury due to a drop.

When replacing the backlight, use the gloves.

Otherwise, it may cause you to be injured.

Start changing the backlight more than 5 minutes after switching the GOT 

power off.

Not doing so can cause a burn due to the heat of the backlight.

When disposing of this product, treat it as industrial waste.

When disposing of batteries, separate them from other wastes according to 

the local regulations.

(Refer to the User's Manual for the GOT you are using for details of the 

battery directive in the EU member states.)

When transporting lithium batteries, make sure to treat them based on the 

transport regulations.

(Refer to the User's Manual for the GOT you are using for details of the 

regurated models.)

Make sure to transport the GOT main unit and/or relevant unit(s) in the 

manner they will not be exposed to the impact exceeding the impact 

resistance described in the general specifications of the User's Manual, as 

they are precision devices.

Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

When fumigants that contain halogen materials such as fluorine, chlorine, 

bromine, and iodine are used for disinfecting and protecting wooden 

packaging from insects, they cause malfunction when entering our products.

Please take necessary precautions to ensure that remaining materials from 

fumigant do not enter our products, or treat packaging with methods other 

than fumigation (heat method).

Additionally, disinfect and protect wood from insects before packing products. 

CAUTION

CAUTION

WARNING

CAUTION

CAUTION

CAUTION

Manual

  

The following shows manuals relevant to this product.

For detailed manuals, refer to the PDF manuals stored in the DVD-ROM for the 

drawing software used.

For relevant manuals, refer to the Help or the PDF manuals stored in the DVD-
ROM for the drawing software used.

The latest manuals are also available from MITSUBISHI ELECTRIC FA Global 
Website (http://www.MitsubishiElectric.co.jp/fa/).

© 2014MITSUBISHI ELECTRIC CORPORATION

Before using the GOT

Connect the connector of the GOT to the connector of the battery.
For details on GT16 specifications, installing procedure, EMC Directive, wiring, 
maintenance and inspection, or checking method for the version and the 
compatible standard, refer to GT16 User's Manual (Hardware).

Packing List

The GOT product package includes the following:

1. FEATURES

(1) Improved monitoring performance and connectivity to FA devices

• GT1695M-X, GT1685M-S, GT1675M-S, GT1675M-V, GT1665M-S, 

GT1665M-V, GT1655-V: The TFT color liquid crystal display (high intensity, 
wide angle view, and high definition type) provides clear full-color display 
and displays small characters clearly.
(Displays digital images of BMP and other formats in 65536 colors.)
GT1675-VN, GT1672-VN, GT1662-VN: The TFT color liquid crystal display 
provides 4096 or 16 colors to offer a wide range of models that meet user 
requirements.

•  Provides multi-language display function based on Unicode2.1 True Type 

font and high-speed drawing of beautiful text.

• High speed monitoring through high speed communication at maximum of 

115.2kbps.

• High speed display and high speed touch switch response.
• The operation performance is improved by the analog touch panel.
• GT1695M-X, GT1685M-S, GT1675M-S, GT1675M-V, GT1665M-S, 

GT1665M-V: Applicable to a video/RGB unit and a multimedia unit

(2) More efficient GOT operations including screen design, startup, adjustment, 

management and maintenance works
• GT1695M-X, GT1685M-S, GT1675M-S, GT1675M-V, GT1665M-S, 

GT1665M-V, GT1655-V: 15MB user memory is included as standard.
GT1675-VN, GT1672-VN, GT1662-VN: 11MB user memory is included as 
standard.

• Interfaces are included as standard. (Ethernet, RS-232, RS-422/485, CF 

card, and USB)

• Font installation is available to increase the system fonts.
• Combined use of 4 types of alarms (system alarm, user alarm, alarm 

history, alarm popup display) realizes more efficient alarm notification.

• Maintenance timing report function is available that measures the backlight 

energization time and notifies of maintenance time.

Detailed Manual

Manual name

Manual number

(Model code)

GT16 User's Manual (Hardware)
                                       (Sold separately)

SH-080928ENG

(1D7MD3)

GT16 User's Manual (Basic Utility)
                                       (Sold separately)

SH-080929ENG

(1D7MD4)

Relevant Manuals

Model name

Product

Quantity

GT1695M-X

GOT

1

Battery (GT15-BAT)

1

Installation fitting

8

GT16 General Discription

1

GT16 本体概要説明書

1

GT1685M-S
GT1675M-S
GT1675M-V
GT1675-VN
GT1672-VN
GT1665M-S
GT1665M-V

GOT

1

Battery (GT15-BAT)

1

Installation fitting

4

GT16 General Discription

1

GT16 本体概要説明書

1

GT1655-V

GOT

1

Battery (GT11-50BAT)

1

Installation fitting

4

GT16 General Discription

1

GT16 本体概要説明書

1

• The USB interface is positioned on the GOT front.  This enables the system 

startup to be performed more efficiently using FA device startup tool, and 
eliminates the necessity of indirect works (opening and closing the control 
panel, cable replacement, cable rewiring) in order to improve the working 
efficiency.

• The blown backlight bulb can be confirmed even during screen saving, with 

the blinked POWER LED at backlight shutoff detection.

(3) Enhanced support of FA device setup tools

• Transferring and monitoring sequence programs with the personal computer 

connected to the GOT can be executed when connecting to a PLC CPU 
with the direct CPU connection or bus connection. (FA transparent function)

2. Part Names and Settings

Part Names and Settings of the GT16

*1: No video/RGB interface on the GT1675-VN, GT1672-VN, GT1662-VN, and 

GT1655-V.

*2: Battery holder for the GT1665 and GT1662.

*3: No extension interface 2 on the GT1655.

*4: Located on the extension interface 2 on the GT1655.

*5:Integral with the CF card interface cover for the GT1655. 

*6:No human sensor on the GT1675, GT1672, GT1665, GT1662, and GT1655.

*7:No LG terminal on the GT1655.

*8:On the rear face of the GT1655, the functional ground terminal is located on the 

left side of the FG terminal.

No.

Name

Description

1)

POWER LED

Lit in green : Power is correctly supplied , Lit in orange : 
Screen saving
Blinks in orange/green : Blown back light bulb , Not lit : 
Power is not supplied

2)

Display screen

Displays the Utility and the user creation screen.

3)

Touch key

For operating touch switches in the Utility and the user 
creation screen

4)

USB interface (Device)

For connecting a personal computer (Connector type: Mini-
B)

5)

USB interface (Host)

For USB mouse/keyboard ,data transfer and storage 
(Connector type: TYPE-A)

6)

RS-232 interface

For communicating with a controller or connecting a 
personal computer(Connector type: D sub 9-pin)

7)

Ethernet interface

For communicating with a controller or using the gateway 
function (Connector type: RJ-45 (modular jack))

8)

RS-422/485 interface

For communicating with a controller (Connector type: 14-pin 
(female))

9)

Power terminal

*8

Power input terminal, LG terminal

*7

, FG terminal

10) Extension interface1

For installing an extension unit (I/F-1)

11) Extension interface2

*3

For installing an extension unit (I/F-2)

12) CF card interface

For installing a CF card

13) CF card access LED

Lit : CF card accessed , Not lit : CF card not accessed

14) CF card access switch

Used for accepting or stopping the access to the CF card 
before removing the CF card from the GOT
ON

:CF card being accessed (CF card removal

       prohibited)

OFF

:CF card not accessed (CF card removal possible)

15) Video/RGB interface

*1

For mounting the video input unit, RGB input unit, video/
RGB input unit, RGB output unit, or multimedia unit

16)

Terminating resistor 
setting switch

For switching on and off of the terminating resistor for the 
RS-422/485 communication port

17)

Optional function 
board interface

*4

For installing the optional function board

18) Reset switch

Hardware reset switch (Inoperative in the bus connection or 
with the bus connection unit installed)

19)

Hole for unit 
installation fitting

Hole for inserting the unit installation fitting

20) Battely cover

*2*5

Houses the battery

21) Human sensor

*6

Sensor that detects human movement

22) Installation switch

Used for OS installations at the GOT startup

GOT 
Rear face

20)

12)

13)
14)

21)

1)

4)
5)

2),3)

19)

6) 7) 8)

9)

10)

11)

18)

17)

16)15)

22)

Example)
GT1695

19)

19)

3. Specifications

3.1 General Specifications 

*1: When mounting a multimedia unit (GT16M-MMR), MELSECNET/H 

communication unit (GT15-J71LP23-25, GT15-J71BR13), or CC-Link 

communication unit (GT15-J61BT13), the operating ambient temperature must 

be reduced 5 °C against the maximum values described in general 

specifications.

     Lors du montage d'un module multimédia (GT16M-MMR), du module de 

communication MELSECNET/H (GT15-J71LP23-25, GT15-J71BR13) ou du 

module de communication CC-Link (GT15-J61BT13), la température ambiante 

de fonctionnement doit être réduite de 5°C par rapport aux valeurs maximales 

décrites dans les spécifications générales.

*2: Do not use or store the GOT under pressure higher than the atmospheric 

pressure of altitude 0m (0ft.).  Failure to observe this instruction may cause a 

malfunction.

When an air purge is made inside the control panel by adding pressure, there 

may be a clearance between the surface sheet and the screen making it difficult 

to use the touch panel, or the sheet may come off.

*3: This indicates the section of the power supply to which the equipment is 

assumed to be connected between the public electrical power distribution 

network and the machinery within the premises.

Category II applies to equipment for which electrical power is supplied from 

fixed facilities.

The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.

*4: This index indicates the degree to which conductive material is generated in the 

environment where the equipment is used.

In pollution degree 2, only non-conductive pollution occurs but temporary 

conductivity may be produced due to condensation.

3.2 Power Supply Specifications

The following indicates the power supply specifications for GT16

.

3.2.1 For GOTs powered from the 100 to 240VAC

power supply

Item

Specifications

Operating 
ambient 
temperature

*1

Température 

ambiante de 
fonctionnem

ent

*1

Display 
section

Zone 
d'affichage

0 to 50

0 à 50

Other than 
the display 
section

Autre que la 
zone 
d'affichage

0 to 55

0 à 55

Storage ambient 

temperature

-20 to 60

Operating ambient 

humidity

10 to 90% RH, non-condensing

Storage ambient humidity

10 to 90% RH, non-condensing

Vibration resistance

Compliant 

with JIS B 

3502 and 

IEC 61131-

2

Frequency

Acceleration

Half-

amplitude

Sweep 

count

Under 

intermittent 

vibration

5 to 8.4Hz

-

3.5mm

10 times 

each in X, 

Y and Z 

directions

8.4 to150Hz

9.8m/s

2

-

Under 

continuous 

vibration

5 to 8.4Hz

-

1.75mm

-

8.4 to 150Hz

4.9m/s

2

-

Shock resistance

Compliant with JIS B 3502 and IEC 61131-2 147 m/s

2

(15G), 

3 times each in X, Y and Z directions

Operating atmosphere

No greasy fumes, corrosive gas, flammable gas, excessive 

conductive dust, and direct sunlight (Same as storage 

atmosphere)

Operating altitude

*2

2000 m (6562 ft) max.

Installation location

Inside control panel

Overvoltage category

*3

II or less

Pollution degree

*4

2 or less

Cooling method

Self-cooling

Grounding

Grounding with a resistance of 100

 or less 

Point

Refer to GT16 User's Manual for details of the performance specifications of each GOT.

Note

Operation at momentary failure
• If an instantaneous power failure occurs in the power supply and continues for more 

than the permissible period, the GOT will be reset.

• Make sure to power on the unit more than 5 seconds after power-off.

Item

Specifications

GT1695M-XTBA GT1685M-STBA

GT1675M-STBA

GT1675M-VTBA

GT1675-VNBA

GT1672-VNBA

GT1665M-STBA
GT1665M-VTBA

GT1662-VNBA

Input power supply voltage

100 to 240VAC (+10%, -15%)

Input frequency

50/60Hz   5%

Input max. apparent power

150VA 

(maximum load)

110VA 

(maximum load)

100VA 

(maximum load)

Power consumption

64W or less

46W or less

39W or less

At backlight off

38W or less

32W or less

30W or less

Inrush current

28A or less (4ms) (maximum load)

3.2.2 For GOTs powered from the 24VDC power

supply

3.3 External Dimensions

Item

Specifications

GT1695M-XTBA GT1685M-STBA

GT1675M-STBA

GT1675M-VTBA

GT1675-VNBA
GT1672-VNBA

GT1665M-STBA

GT1665M-VTBA

GT1662-VNBA

Allowable momentary power 

failure time

20 ms or less (100VAC or more)

Noise immunity

1,500Vp-p noise voltage, 1 s noise width (when 

measuring with a noise simulator under 25 to 60Hz 
noise frequency)

Dielectric withstand voltage

1500VAC for 1 minute across power terminals and earth

Insulation resistance

10M

 or more across power terminals and earth by a 

500V DC insulation resistance tester

Applicable wire size

0.75 to 2[mm

2

]

Applicable solderless terminal

Solderless terminal for M3 screw RAV1.25-3, V2-S3.3, 

V2-N3A, FV2-N3A

Applicable tightening torque 

(Terminal block terminal screw)

0.5 to 0.8[N•m]

Item

Specifications

GT1695M-

XTBD

GT1685M-

STBD

GT1675M-STBD

GT1675M-VTBD

GT1675-VNBD

GT1672-VNBD

GT1665M-STBD

GT1665M-VTBD

GT1662-VNBD

GT1655-VTBD

Input power supply 
voltage

DC24V (+25%, -20%)

Power 

consumption

60W or less

40W or less

38W or less

16W or less

At backlight off

30W or less

26W or less

27W or less

14W or less

Inrush current

12A or less 

(75ms) 

(maximum 

load)

12A or less (55ms) (maximum 

load)

67A or less 
(1ms) 

(maximum 

load)

Allowable 
momentary power 

failure time

10 ms or less

Noise immunity

500Vp-p noise voltage, 1 s noise width (when measuring with a 

noise simulator under 25 to 60Hz noise frequency)

Dielectric withstand 
voltage

500VDC for 1 minute across power terminals and earth

Insulation 

resistance

10M

 or more across power terminals and earth by a 500V DC 

insulation resistance tester

Applicable wire size

0.75 to 2[mm

2

]

Applicable 

solderless terminal

Solderess terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-

N3A 

Applicable 

tightening torque 
(Terminal block 

terminal screw)

0.5 to 0.8[N•m]

Unit:mm (inch)

397(15.6)
320(12.6)

296(11.7)

320(12.6)

6(0.24)

61(2.40) 10

382(15.0)

10

281(11.1)

(0.39)

(0.39)

GT1695

10(0.39)

10(0.39)

 Unit: mm (inch)

316(12.44)
240(10.35)

242(9.53)

240(9.84)

301(11.85)

52(2.05)

56(2.20)

227(8.94)

10(0.39)

GT1685

10(0.39)

6(0.24)

303 (11.93)

252 (9.92)

10(0.39)

199 (7.83)

214 (8.43)

10(0.39)

56 (2.20)

49

(1.93)

288 (11.34)

222 (8.74)

 Unit: mm (inch)

GT1675,GT1672

6(0.24)

190 (7.48)

10(0.39)

175 (6.89)

226 (8.90)

52

(2.05)

175.5 (6.91)

175.5 (6.91)

241 (9.49)

56 (2.20)

10(0.39)

6(0.24)

 Unit: mm (inch)

GT1665,GT1662

135(5.31)

10(0.39)

10(0.39)

120(4.72)

152(5.98)

6

(0.24)

116(4.57)

167(6.57)

60(2.36)

GT1655

116(4.57)

 Unit: mm (inch)

Reviews: