14 - 8
14. CC-Link CONNECTION (Via G4)
14.2 System Configuration
14.2.2 Connecting to LCPU
*1
For the system configuration of the CC-Link module, refer to the following manual.
MELSEC-L CC-Link System Master/Local Module User's Manual
*2
For the specifications and inquiries of the CC-Link dedicated cable, refer to the following.
CC-Link Partner Association's home page: http://www.cc-link.org/
*3
The maximum overall extension cable length and the length between stations vary depending on the cable type to be used and
the transmission speed.
For details, refer to the following manual.
MELSEC-L CC-Link System Master/Local Module User's Manual
*4
For the connection to GOT, refer to the connection diagram.
*5
Connect it to the RS-232 interface (built into GOT). It cannot be mounted on GT1655 and GT155 .
PLC
Connection cable 1)
Peripheral connection
module
Connection cable 2)
GOT
Number of
connectable
equipment
Model
name
CC-Link
module
*1
Cable
model
Max.
distance
Model
name
Communication
type
Cable model Connection
diagram number
Max.
distance
Option
device
Model
L02CPU
L26CPU-
BT
L02CPU-P
L26CPU-
PBT
LJ61BT1
1
CC-Link
dedicated
cable
*2
*3
AJ65B
T-R2N
RS-232
GT09-C30R2-9P
or
15m
- (Built into
GOT)
1 GOT for
1 peripheral
connection
module
15m
- (Built into
GOT)
AJ65B
T-G4-
S3
RS-422
GT01-C30R4-25P(3m)
GT01-C100R4-25P(10m)
GT01-C200R4-25P(20m)
GT01-C300R4-25P(30m)
30m
GT16-
C02R4-9S
GT15-
RS2T4-9P
*5
GT15-RS4-
9S
- (Built into
GOT)
GT10-C30R4-25P(3m)
GT10-C100R4-25P(10m)
GT10-C200R4-25P(20m)
GT10-C300R4-
25P(30m)
*4
30m
- (Built into
GOT)
L26CPU-
BT
L26CPU-
PBT
-
CC-Link
dedicated
cable
*2
*3
AJ65B
T-R2N
RS-232
GT09-C30R2-9P
or
15m
- (Built into
GOT)
1 GOT for
1 peripheral
connection
module
15m
- (Built into
GOT)
AJ65B
T-G4-
S3
RS-422
GT01-C30R4-25P(3m)
GT01-C100R4-25P(10m)
GT01-C200R4-25P(20m)
GT01-C300R4-25P(30m)
30m
GT16-
C02R4-9S
GT15-
RS2T4-9P
*5
GT15-RS4-
9S
- (Built into
GOT)
GT10-C30R4-25P(3m)
GT10-C100R4-25P(10m)
GT10-C200R4-25P(20m)
GT10-C300R4-
25P(30m)
*4
30m
- (Built into
GOT)
CC-Link (G4)
Communication driver
CC-Link
module
LCPU
Peripheral
connection
module
Connection cable 2)
GOT
Connection cable 2)
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......