background image

User's Manual

GT15-J71GP23-SX

Thank you for choosing Mitsubishi Electric Graphic Operation 
Terminal (GOT).

GOT2000/GOT1000 Series

CC-Link IE Controller Network

Communication Unit

Prior to use, please read both this manual and detailed manual 
thoroughly to fully understand the product.

MODEL GT15-J71GP23-SX-U
MODEL

CODE

1D7M76

IB(NA)-0800412-I(1806)MEE

Summary of Contents for GT15-J71GP23-SX

Page 1: ...Graphic Operation Terminal GOT GOT2000 GOT1000 Series CC Link IE Controller Network Communication Unit Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 J71GP23 SX U MODEL CODE 1D7M76 IB NA 0800412 I 1806 MEE ...

Page 2: ...ns are ranked as WARNING and CAUTION Note that the CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are important to personal safety Please save this manual to make it accessible when required and always forward it to the end user Indicates that incorrect handling may cause hazardous conditions resulting in death ...

Page 3: ...ng cable disconnection occurs during monitoring the communication between the GOT and programmable controller CPU may be interrupted and the GOT may be inoperative For bus connection The programmable controller CPU is down and the GOT is inoperative For other than above The GOT is inoperative When configuring a system including the GOT the possibility of GOT communication error must be considered ...

Page 4: ... installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range 0 36 N m to 0 48 N m with a Phillips head screwdriver No 2 Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage Do not directory touch the conductive part or electronic comp...

Page 5: ...amage of the unit or the cables due to accidental pull or unintentional shifting of the cables or malfunctions due to poor contact of the cables Do not hold the cable by hand and pull it out from the unit When removing the cable from the unit make sure to hold the connector by hand and pull it Failure to do so may cause malfunctions or damage to the unit or cable Do not touch the connector while p...

Page 6: ...cause a failure or malfunctions of the unit Dispose of this product as industrial waste Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of Use this unit in the environment that satisfies the general specifications described in the User s Manual for the GOT us...

Page 7: ... South Korea Oct 2014 IB NA 0800412 E Partial corrections SAFETY PRECAUTIONS Chapter 4 7 May 2014 IB NA 0800412 F Partial corrections Cover Oct 2016 IB NA 0800412 G Partial corrections Compliance with the RoHS Apr 2017 IB NA 0800412 H Partial corrections Cover Jun 2018 IB NA 0800412 I Patial addition Compliance with Chinese standardized law This manual confers no industrial property rights or any ...

Page 8: ...A 7 CONTENTS 1 OVERVIEW 1 2 SPECIFICATIONS 1 3 PART NAMES 3 4 INSTALLATION PROCEDURE 6 5 PRECAUTIONS FOR WIRING CABLES 8 6 WIRING METHOD 9 7 EXTERNAL DIMENSIONS 10 ...

Page 9: ...ate of the GOT Manual The following shows manuals relevant to this product For relevant manuals refer to the PDF manuals stored in the DVD ROM for the drawing software used Detailed Manual Manual name Manual number Model code GOT2000 Series User s Manual Hardware Sold separately SH 081194ENG 1D7MJ5 GOT2000 Series Connection Manual Mitsubishi Products For GT Works3 Version1 Sold separately SH 08119...

Page 10: ... GB T15969 2 Requirement of Chinese standardized law Packing List The following items are included Note This symbol mark is for China only 部件名称 有害物质 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 电路板组件 树脂壳体 电缆 膜材 钣金部件 螺丝等金属部件 Model Product Quantity GT15 J71GP23 SX CC Link IE Controller Network communication unit 1 Mounting screw set 4 screws 4 stickers 1 Extension interface relay board 1 GOT2000 GOT...

Page 11: ...When using the CC Link IE Controller Network connection make the communication setting to perform communication with programmable controllers For the details of the CC Link IE Controller Network connection refer to the GOT2000 or GOT1000 Series Connection Manual Mitsubishi Products Item Specification Max link points per network LB 32K points 32768 points 4KB LW 128K points 131072 points 256KB LX 8...

Page 12: ...m Core Clad 50 125 m Max number of networks 239 Max number of groups 32 Transmission path Duplex loop Optical fiber specifications 1000BASE SX MMF fiber optic cable Standard IEC60793 2 10 Types A1a 1 50 125 m multimode Transmission loss max 3 5 dB km or less 850nm Transmission band min 500 MHz km or more 850nm Connector specifications Duplex LC connector Standard IEC61754 20 Type LC connector Conn...

Page 13: ...IN side OUT side Connector for connecting a fiber optic cable 2 in this section 3 Interface connector Extension connector installed to a front extension unit or the GOT 4 Extension connector Extension connector to which a back extension unit is installed 5 Board fixing screw Screws for fixing the extension interface relay board 6 Mounting screw Mounting screws fixed with a front extension unit or ...

Page 14: ...N LED is blinking the LED display format is the error mode In the error mode if an error occurs restart the GOT If the error mode is not released after restarting the GOT the system alarm 460 Communication unit error may occur For system alarms refer to the User s Manual for the GOT used LED name Status Description RUN Off The GOT is being reset On The unit is in a normal status SD Off Not sending...

Page 15: ...5 2 Connector IN side OUT side IN Forward loop receiving IN Reverse loop sending OUT Reverse loop receiving OUT Forward loop sending OUT IN ...

Page 16: ... on the GOT After the installation detach the connector cover from the extension interface relay board For the following GOT types the extension interface relay board is not needed GT1655 GT155 of the GOT1000 series GT27 GT25 of the GOT2000 series 4 Fit the CC Link IE communication unit in the GOT case 5 Fix the CC Link IE communication unit by tightening its mounting screws 4 places with a tighte...

Page 17: ...the stickers When not installing an extension unit on the unit that has been installed in order to avoid receiving electrostatic stick accessory stickers to cover the top of mounting screws 4 places Keep the connector cover fixed Keep the accessory sticker stuck Point Remove the screws that fixes the extension interface relay board before removing the unit Above 6 6 5 Sticker Accessory sticker Acc...

Page 18: ... or removing the fiber optic cables to from the unit hold the cable connector securely with the hands 5 Connect the cable connector and unit connector securely until you hear a click sound 6 For connecting or removing the fiber optic cables be sure to shut off all phases of the external power supplies used in the system 7 Please wire IN OUT of the connector for the cable correctly After wiring per...

Page 19: ...ller Network module Power supply module CPU module CC Link IE communication unit IN OUT IN OUT IN OUT n 120 Connector hook CC Link IE communication unit Unit side connector Cable side connector Connection Connect the cable side connector to the module side connector paying attention to the orientation Push it until a click is heard Lightly pull it to check that it is securely connected Completed T...

Page 20: ...o the GOT GOT GT27 GT25 GT16 GT15 15 37 1 46 33 5 1 32 35 1 38 12 1 37 1 46 37 1 46 32 1 26 32 1 26 10 4 37 1 46 37 1 46 35 1 38 35 1 38 8 4 37 1 46 37 1 46 37 1 46 37 1 46 5 7 37 1 46 37 1 46 37 1 46 133 5 24 3 0 12 98 3 86 2 5 0 10 2 0 08 35 1 38 44 1 73 11 5 0 45 15 5 0 61 23 5 0 93 3 0 12 15 0 59 120 4 72 X GOT main unit Unit mm inch ...

Page 21: ...11 2 Extension interface relay board ...

Page 22: ...e B V Italian Branch Centro Direzionale Colleoni Palazzo Sirio Viale Colleoni 7 Agrate Brianza MB Italy Tel 39 039 60531 Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 Apdo 420 08190 Sant Cugat del Valles Barcelona Spain Tel 34 935 65 3131 Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets 92741 Nanterre Cedex France Tel 33 1 55 68 55 68 Mitsubishi Electri...

Reviews: