JY997D43001D
Safety Precautions
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Depending on the circumstances, procedures indicated by
may
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
How to obtain manuals
For product manuals or documents, consult with your local Mitsubishi Electric
representative.
Certification of UL, cUL standards
FX
3U
-J1939 units comply with the UL standards (UL, cUL).
UL, cUL File Number: E95239
Regarding the standards that comply with the main unit, please refer to either the
FX series product catalog or consult with your nearest Mitsubishi product provider.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Manual name
Manual No.
Description
FX
3U
-J1939
User’s Manual
JY997D43101
Describes details of the FX
3U
-
J1939 Communication Special
Function Block.
FX
3G
Series
User’s Manual
- Hardware Edition
JY997D31301
MODEL CODE:
09R521
Explains the FX
3G
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX
3GC
Series
User’s Manual
- Hardware Edition
JY997D45401
MODEL CODE:
09R533
Explains the FX
3GC
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX
3U
Series
User’s Manual
- Hardware Edition
JY997D16501
MODEL CODE:
09R516
Explains the FX
3U
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX
3UC
Series
User’s Manual
- Hardware Edition
JY997D28701
MODEL CODE:
09R519
Explains the FX
3UC
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
should be checked by the user / manufacturer. For more information please consult
with your nearest Mitsubishi product provider.
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2004/108/EC) when
used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Note
Authorized Representative in the European Community:
Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
3U
series manufactured
from May 1st, 2012
FX
3U
-J1939
Caution for Compliance with EC Directive
1) Caution for wiring
For noise prevention, please ground at least 35 mm (1.38") of the twisted-pair
cable along the grounding plate to which the ground terminal is connected.
Refer to subsection 3.2.3
2) Installation in Enclosure
For details regarding installation in an enclosure,
refer to the User’s Manual - Hardware Edition of the respective PLC main unit
1. Introduction
The FX
3U
-J1939 communication block is an interface block that allows FX
3G
/FX
3GC
/
FX
3U
/FX
3UC
Series PLCs to connect to a J1939 system. FX
3U
-J1939 can be
connected directly to the FX
3G
/FX
3GC*1
/FX
3U
/FX
3UC*1
series PLC's extension port, or
to any other extension unit / block's right side extension port.
Specification abstract:
75 messages (8 bytes / message) and 4 extension messages (a maximum of 250
bytes / message) can be sent and received on J1939 communication.
A Command Interface (CIF) for asynchronous services and configuration, and
diagnosis
CAN Layer 2 communication
*1 An FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is necessary to connect the FX
3U
-J1939 to
an FX
3GC
/FX
3UC
Series PLC.
Standard
Remark
EN61131-2:2007
Programmable controllers
- Equipment requirements
and tests
Compliance with all relevant aspects of the standard.
EMI
• Radiated Emission
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in a
device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However when
installing the product where major accidents or losses could occur if the product
fails, install appropriate backup or failsafe functions in the system.
1.1 Incorporated Items
Check to ensure the following product and items are included in the package.
1.2 External Dimensions and Part Names
1.3 Power and status LEDs
*1 For details, refer to the following manual.
FX
3U
-J1939 User's Manual
1.4 Terminal Layout
Included Item
FX
3U
-J1939
1 unit
Terminating resistor (120
1 piece
Special unit/block No. label
1 sheet
Dust proof protection sheet
1 sheet
Manual (English version only)
1 manual
[1]
Extension cable
[6]
DIN rail mounting groove
(DI N ra il : D IN 462 77 , 35 m m
(1.38") width)
[2]
Direct mounting hole
2 holes of
4.5 (0.18")
(mounting screw: M4 screw)
[7]
Nameplate
[3]
Status LEDs (see section 1.3)
[8]
DIN rail mounting hook
[4]
Power LED (green)
[9]
CAN bus connector
[5]
Top cover
LED
Name
LED
Color
Status
Description
RUN
Green
OFF
Module is offline.
ON
Module is online.
FROM/TO Green
OFF
PLC is not accessing BFMs in module.
ON
PLC is accessing BFMs in module.
Tx/Rx
Green
OFF
M o d u l e i s n o t t r a n s m i t t i n g o r r e c e i v i n g
messages.
ON
Module is transmitting or receiving messages.
ERROR
Red
OFF
Normal operation (status)
SINGLE
FLASH
*1
Error passive state
BLINKING
*1
General error
ON
BUS-OFF state
POWER
Green
ON
24 V DC power is properly supplied from PLC
main unit.
Pin No.
Signal
Description
1
CAN_GND
Ground / 0 V / V-
2
CAN_L
CAN_L bus line
(dominant low)
3
(CAN_SHLD) Optional CAN shield
4
CAN_H
CAN_H bus line
(dominant high)
5
(CAN_V+)
O p t i o n a l C A N e x t e r n a l
positive supply
(not connected internally)
90 (3.55")
80 (3.15")
(mounting hole pitch)
43 (1.7")
4 (0.16")
87 (3.43")
8
(0.32")
9 (0.36")
[3]
[2]
[4]
[6]
[8]
[7]
2- 4.5 mounting holes
[9]
[1]
[5]
Unit: mm
MASS (Weight): 0.2 kg (0.44 lbs)
CAN_GND
CAN_L
CAN_SHLD
CAN_H
CAN_V+
2. Installation
For installation details, refer to the following manual.
FX
3U
-J1939 User's Manual
2.1 Connection with PLC
The FX
3U
-J1939 connects on the right side of a PLC main unit or extension units/
blocks (including special function units/blocks).
For connection to an FX
3GC
/FX
3UC
Series PLC or FX
2NC
Series PLC extension
block, an FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is required.
For details, refer to the respective PLC manual.
Refer to the FX
3G
Series User's Manual - Hardware Edition
Refer to the FX
3GC
Series User's Manual - Hardware Edition
Refer to the FX
3U
Series User's Manual - Hardware Edition
Refer to the FX
3UC
Series User's Manual - Hardware Edition
2.2 Mounting
The product is mounted by the following method.
DIN rail mounting
Direct mounting (mounting screw: M4 screw)
For details, refer to the respective PLC manual.
Refer to the FX
3G
Series User's Manual - Hardware Edition
Refer to the FX
3GC
Series User's Manual - Hardware Edition
Refer to the FX
3U
Series User's Manual - Hardware Edition
Refer to the FX
3UC
Series User's Manual - Hardware Edition
3. Wiring
For wiring details, refer to the following manuals.
FX
3U
-J1939 User's Manual
INSTALLATION
PRECAUTIONS
Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl
2
, H
2
S, SO
2
or NO
2
), flammable gas,
vibration or impacts, or expose it to high temperature, condensation, or rain
and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
When drilling screw holes or wiring, make sure that cutting and wiring debris
do not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Be sure to remove the dust proof sheet from the PLC's ventilation port when
installation work is completed.
Failure to do so may cause fire, equipment failures or malfunctions.
Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformities.
Install the product securely using a DIN rail or mounting screws.
Connect extension cables securely to their designated connectors.
Loose connections may cause malfunctions.
WIRING PRECAUTIONS
Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING PRECAUTIONS
Perform class D grounding (grounding resistance: 100
or less) to the shield
of the twisted shield cable (refer to subsection 3.2.3).
Do not use common grounding with heavy electrical systems (refer to the
manual of the PLC main unit).
When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Install module so that excessive force will not be applied to communication
connectors or communication cables.
Failure to do so may result in wire damage/breakage or PLC failure.
Make sure to affix the CAN bus connector with fixing screws.
Tightening torque should follow the specifications in the manual.
Loose connections may cause malfunctions.
FX
3U
-J1939
INSTALLATION MANUAL
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective April 2015
Specifications are subject to change without notice.
2012 Mitsubishi Electric Corporation
Manual Number
JY997D43001
Revision
D
Date
April 2015