5 Introduction of Functions
5.10 Application Profile CiA
®
417 V2.1 for Lift Control Systems
101
FX
3U
-CAN User's Manual
1
Introduc
tion
2
Specifi
cations
3
Inst
allati
on
4
Wi
rin
g
5
Introduc
tion of
Functions
6
All
ocation of
B
uff
er
Memor
ies
7
Interface and
D
evice P
rofile
(40
5 mode)
8
Lift Appl
icati
on
P
ro
file
(417 M
ode)
9
CAN
Layer 2
Mode
10
Comm
and
Interface
3. Finger protector field
4. Motion detector field
5. Door velocity field
6. Command field
5.10.5 Door status word
This Object contains the car door status and other status information.
1. Safety contact field
Bit 6 to 7 Value (hex)
Description
0
Enable finger protector
1
Disable finger protector
2
Reserved
3
Do not care / take no action
Bit 8 to 9 Value (hex)
Description
0
Enable motion detector
1
Disable motion detector
2
Reserved
3
Do not care / take no action
Bit 10 to 11 Value (hex)
Description
0
Move door with standard speed
1
Move door with reduced speed
2
Reserved
3
Do not care / take no action
Bit 12 to 15 Value (hex)
Description
0
Close door without limit force (Not allowed for EN-81 compliant lifts)
1
Close door with limit force
2
Nudging
(Forced closing of car door with reduced speed without reversal devices due to the door being blocked for too
long)
3
Open door without limit force (Not allowed for EN-81 compliant lifts)
4
Open door with limit force
5
Reserved
6
Reserved
7
Stop door without torque
8
Stop door with torque
9 to C
Reserved
D
Tech-in drive
E
Reset door
F
Do not care / take no action
Bit 0 to 1 Value (hex)
Description
0
Contact not closed
1
Contact closed
2
Error indicator
3
Not available or not installed
Status
Safety
contact
Battery
power
Door lock
Finger
protector
Motion
detector
Force
limit
15 ... 12
11 ... 10
9 ... 8
7 ... 6
5 ... 4
3 ... 2
1 ... 0