Mitsubishi Electric FX3U-64CCL Installation Manual Download Page 1

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for 

accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

JY997D29801F

Side

B

Safety Precautions

 

(Read these precautions before use.)

This manual classifies the safety precautions into two categories: 

 and 

.

Depending on circumstances, procedures indicated by 

 may also

cause severe injury.
It is important to follow all precautions for personal safety.

Associated Manuals

Manuals for the FX

3G

 PLC will be available in September 2008 or later.

How to obtain manuals

For product manuals or documents, contact the Mitsubishi Electric dealer from
whom you purchased your product.

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.

Manual name

Manual No.

Description

FX

3G

 Series 

User’s Manual 
- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains the FX

3G

 Series PLC

specifications for I/O, wiring,
installation, and maintenance. 

FX

3GC

 Series 

User’s Manual 
- Hardware Edition

JY997D45401

MODEL CODE: 

09R533

Explains the FX

3GC

 Series PLC

specifications for I/O, wiring,
installation, and maintenance. 

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains the FX

3U

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3UC

 Series 

User’s Manual 
- Hardware Edition

JY997D28701

MODEL CODE: 

09R519

Explains the FX

3UC

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series 

Programming Manual 
- Basic & Applied 
Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming for

basic/applied instructions and
devices.

FX

3U

-64CCL 

User’s Manual 

JY997D30401

MODEL CODE: 

09R718

Describes FX

3U

-64CCL type

CC-Link interface block details.

MELSEC iQ-F FX5U
User’s Manual
(Hardware)

JY997D55301

MODEL CODE:

09R536

Explains the FX5U PLC 
specifications for I/O, wiring,
installation, and maintenance.

MELSEC iQ-F FX5UC
User’s Manual
(Hardware)

JY997D61401

MODEL CODE:

09R558

Explains the FX5UC PLC 
specifications for I/O, wiring,
installation, and maintenance.

Certification of UL, cUL standards

FX

3U

-64CCL units comply with the UL standards (UL, cUL).

UL, cUL File Number: E95239
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module

should be checked by the user / manufacturer. For more information please consult
with your nearest Mitsubishi product provider.
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Requirement for Compliance with EMC directive

The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when
used as directed by the appropriate documentation.

Attention

This product is designed for use in industrial applications.
Type:

Programmable Controller (Open Type Equipment)

Models:

MELSEC FX

3U

 series manufactured

from March 1st, 2008

FX

3U

-64CCL

Caution for EC Directive

Installation in Enclosure

Programmable controllers are open-type devices that must be installed and

used within conductive control cabinets. Please use the programmable controller
while installed within a conductive shielded control cabinet. Please secure the
cabinet door to the control cabinet (for conduction). Installation within a control
cabinet greatly affects the safety of the system and aids in shielding noise from
the programmable controller.

Control cabinet

- The control cabinet must be conductive.
- Ground the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door, 

connect the cabinet and its doors with thick wires. 

- In order to suppress the leakage of radio waves, the control cabinet structure 

must have minimal openings. Also, wrap the cable holes with a shielding cover 
or other shielding devices.

- The gap between the control cabinet and its door must be as small as possible 

by attaching EMI gaskets between them.

* These wires are used to improve the conductivity between the door and control cabinet.

Configuration example inside control cabinet 

Standard

Remark

EN61131-2:2007
Programmable controllers

- Equipment

r e q u i r e m e n ts   a n d
tests

Compliance with all relevant aspects of the standard.
EMI
• Radiated Emission                       • Conducted Emission

EMS
• Radiated electromagnetic field   • Fast Transient burst
• Electrostatic discharge                • High-energy surge

• Voltage drops and interruptions  • Conducted RF
• Power frequency magnetic field

Shielding cover

Shielded cable

Wires*

EMI gasket

Main unit

FX

3U

-64CCL

24V DC power

supply

Power

cable

Ground

cable

Ground

cable

Cable clamp

Conductive control cabinet

CC-Link dedicated cable

24+ 24-

DA DB

SLD

DG

L N

(AD75CK,

 MITSUBISHI)

Wiring simplified diagram

Notes for compliance with EN61131-2:2007
General notes on the use of the power supply cable

- The  FX

3U

-64CCL unit requires that the cable used for power supply is 30 m or less.

- When the cable used for power supply exceeds 30 m, a noise filter (Ex. TDK-

Lambda MBS1205-22 or similar) should be placed on the 24 V DC power cabling 
as close (within 500 mm) to the FX

3U

-64CCL termination points as possible, 

refer to following figure.

1. Introduction

The CC-Link interface block FX

3U

-64CCL (hereinafter called 64CCL) is a special

function block to connect the FX

3G

/FX

3GC

/FX

3U

/FX

3UC

/FX5U/FX5UC programmable

controller to a CC-Link network.
The 64CCL works as an intelligent device station on a CC-Link network.
Only one 64CCL unit can be connected to a single programmable controller main unit.

→ 

For system configuration, refer to the FX

3U

-64CCL User's Manual.

1.1 Major Features of the FX

3U

-64CCL

1) Compatible with CC-Link Ver. 2.00 and Ver. 1.10

The 64CCL is compatible with CC-Link Ver. 2.00, and enables expanded cyclic
transmission to facilitate the handling of applications requiring multiple data
processing.
In addition to Ver. 2.00, Ver. 1.10 is also supported with the 64CCL.

1.2 Incorporated Items

Check to ensure the following product and items are included in the package:

1.3 External Dimensions and Part Names 

Included Item

CC-Link interface block FX

3U

-64CCL

1 unit

Special unit/block No. label

1 sheet

Dust proof protection sheet

1 sheet

Installation Manual (This manual)

1 manual

[1] Extension cable
[2] Direct mounting hole: 2 holes of  4.5 (0.18") (mounting screw: M4 screw)
[3] POWER LED (green)
[4] Status LEDs
[5] Name plate
[6] DIN rail mounting groove (DIN rail: DIN46277, 35mm (1.38") width)
[7] DIN rail mounting hook
[8] Power supply terminal block
[9] Extension connector
[10] CC-Link connection terminal block
[11] Number of occupied stations and expanded cyclic setting switch

DA
DB
DG

SLD

FG

DA
DB
DG

SLD

DA
DB
DG

SLD

FG

Master

unit

FX

3U

-64CCL

CC-Link

Dedicated

Cable

(Blue)
(white)
(yellow)

CC-Link

Dedicated

Cable

Other

station

Termi-

nating

resistor

Termi-

nating

resistor

Exceeding 30 m

24 V DC

24 V DC power

supply

500 mm or less

Noise

Filter

FX

3U

-64CCL

FX

3U

-64CCL

POWER

RUN
ERR.
RUN

ERR.

 SD

 RD

L
L

FX

3U

-64CCL

24-

24+

DA

DB

DG

SLD

STATION

NO.

COM

SETTING

B RATE STATION

10

1

X

X

80 (3.15")

(mounting hole pitch)

55 (2.17")

4 (0.16")

[1]

[3]

[2]

[4]

90 (3.55")

87 (3.43")

[6]

9 (0.36")

[10]

[8]

[9]

[11]

[12]

[7]

Without top cover

[5]

Unit: mm (inches)
MASS (Weight): Approx. 0.3 kg (0.66 lbs)

[13]

2-

φ

4.5 mounting holes

1.4 Power and status LEDs

1.5 Terminal layout

Terminal screw and terminal block mounting screw size, and tightening torque
Power supply terminal block, CC-Link connection terminal block: 
  M3 screw, 0.42 to 0.58 N

m

CC-Link connection terminal block mounting screw (black): 
  M3.5 screw, 0.66 to 0.91 N

m

Do not tighten the terminal block mounting screws with a torque outside the
above-mentioned range.
Failure to do so may cause equipment failures or malfunctions.

CC-Link connection terminal block can be detached or attached. Make sure to cut
off all phases of the power supply externally.
For details on the wiring and the types of connection cables needed to connect to
the terminal blocks shown in the figure above, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

1.6 Switch setting

With regard to the switch setting for station number, transmission rate, hardware
test, number of occupied stations and expanded cyclic transmission, the switch
settings become valid after 64CCL startup.
If the switch settings are changed after 64CCL startup, the L ERR. LED will flicker.
To change the switch setting, power OFF the 64CCL once, and power it ON again.
For details on the switch setting, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

[12] Transmission rate setting switch
[13] Station number setting switch

LED 

display

Color Status

Description

POWER Green

OFF

Power is not being supplied from the external power
supply (24 V DC).

ON

Power is being supplied from the external power
supply (24 V DC).

RUN

Green

OFF

64CCL has failed.

ON

Under 64CCL normal operation.

ERR.

Red

OFF

No errors.

ON

Error in the settings, error in the parameter details,
error with the communication, errors with the H/W.

L RUN

Green

OFF

Offline.

ON

Data link is being executed.

L ERR.

Red

OFF

No communication error.

Flicker

The switch setting was changed after start.
There is no terminating resistor.
Influence from noise.

ON

There is a data linking error.
There is a setting error.

SD

Green

OFF

Data is not being sent.

ON

Data is being sent.

RD

Green

OFF

Data is not being received.

ON

Data is being received.

CC-Link connection

terminal block

Power supply

terminal block

24+

24-

DA

DB

SL
D

DG

1.6.1

Station number setting

1.6.2

Transmission rate setting, hardware test

1.6.3

 Number of occupied stations, expanded cyclic setting

2. Installation

For details on anchoring, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

Setting items

Range

Description

×

 10

0 to 6

1 to 64
0, 65 to 99 is the setting error.

×

 1

0 to 9

Setting

Description

Status

0

Transmission rate 156 Kbps

Online

1

Transmission rate 625 Kbps

2

Transmission rate 2.5 Mbps

3

Transmission rate 5 Mbps

4

Transmission rate 10 Mbps

5 to 9

Unusable

Unusable

A

Transmission rate 156 Kbps

Hardware test

B

Transmission rate 625 Kbps

C

Transmission rate 2.5 Mbps

D

Transmission rate 5 Mbps

E

Transmission rate 10 Mbps

F

Unusable

Unusable

Setting

Number of occupied stations

Expanded cyclic setting

0

1 station

Single

1

2 stations

Single

2

3 stations

Single

3

4 stations

Single

4

1 station

Double

5

2 stations

Double

6

3 stations

Double

7

4 stations

Double

8

1 station

Quadruple

9

2 stations

Quadruple

A, B

Unusable

Unusable

C

1 station

Octuple

D to F

Unusable

Unusable

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting installation
work.
Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in PLC main unit
manual (Hardware Edition). Never use the product in areas with excessive dust, oily
smoke, conductive dusts, corrosive gas (salt air, Cl

2

, H

2

S, SO

2

 or NO

2

), flammable gas,

vibration or impacts, or expose it to high temperature, condensation, or rain and wind. If
the product is used in such conditions, electric shock, fire, malfunctions, deterioration or
damage may occur.

Do not touch the conductive parts of the product directly.  Doing so may cause device
failures or malfunctions.

Install the product securely using a DIN rail or mounting screws.

Install the product on a flat surface. If the mounting surface is rough, undue force will be
applied to the PC board, thereby causing nonconformities.

When drilling screw holes or wiring, make sure that cutting and wiring debris do not enter
the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.

Be sure to remove the dust proof sheet from the PLC's ventilation slits when installation
work is completed. Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to attach the top cover, offered as an accessory, before turning on the power
or initiating operation after installation or wiring work. Failure to do so may cause electric
shock.

Connect extension cables securely to their designated connectors. Loose connections
may cause malfunctions.

2.1 Connection with PLC

Only one 64CCL can be connected to the right side of a PLC main unit or extension
unit/block (including special function units/blocks). 
For connection to an FX

3GC

/FX

3UC

 Series PLC or FX

2NC

 Series PLC extension block,

an FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is required. 

For connection to FX5U/FX5UC PLC, FX5-CNV-BUS or FX5-CNV-BUSC is required.
For further information on installation arrangements, refer to the following manuals.

→ 

For details, refer to the FX

3G

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the FX

3GC

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the FX

3U

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the FX

3UC

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the MELSEC iQ-F FX5U User's Manual (Hardware).

→ 

For details, refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).

2.2 Mounting

The product is mounted by the following method. 

DIN rail mounting

Direct mounting (mounting screw: M4 screw)

For further information on installation arrangements, refer to the following manuals. 

→ 

For details, refer to the FX

3G

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the FX

3GC

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the FX

3U

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the FX

3UC

 Series User's Manual- Hardware Edition.

→ 

For details, refer to the MELSEC iQ-F FX5U User's Manual (Hardware).

→ 

For details, refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).

2.2.1

DIN Rail Mounting

The product can be mounted on a DIN rail (DIN46277, 35mm (1.38") width).

1) Fit the upper edge of the DIN rail mounting

groove (fig. A) onto the DIN rail. 

2) Press the product against the DIN rail. 

- An interval space of 1 to 2 mm (0.04" to 

0.08") between each unit is necessary.

2.2.2

Direct Mounting (mounting screw: M4 screw)

The product can be installed directly with screws.
Refer to the External Dimensions (section 1.3) for the product’s mounting hole pitch
information. 
An interval space between each unit of 1 to 2 mm (0.04" to 0.08") is necessary. 

3. Specification

For details on specifications, refer to the following manual.

→ 

Refer to the FX

3U

-64CCL User's Manual.

DESIGN
PRECAUTIONS

For the status of each station when the main unit stops calculation or when a communication
error occurs in the data link, thoroughly read the description of data link processing time in the
CC-Link master module manual. Construct an interlock circuit in the sequence program using
the communication status information (BFM, SB, SW) so that the system always works
conservatively.
Erroneous outputs and malfunctions may cause accidents.
1) Setting to hold or clear the input information against data link error

Remote outputs (RY) and remote registers (RWw) are held or cleared in accordance with
the setting of BFM #32.
   0 (default): Data prior to the error is held.
   Other than 0: Data prior to the error is cleared.

2) Setting to hold or clear the data against a stop in the main unit

Remote inputs (RX) and remote registers (RWr) are held or cleared in accordance with the
setting of BFM #33.
   0 (default): Data prior to the stop is held.
   Other than 0: Data prior to the stop is cleared.

When executing control (data changes) to an operating PLC, construct an interlock circuit in
the sequence program so that the entire system operates conservatively. 
In addition, when executing control such as program changes and operation status changes
(status control) to an operating PLC, thoroughly read the manual and sufficiently confirm safety
in advance. 
Especially in control from external equipment to a PLC in a remote place, problems in the PLC
may not be able to be handled promptly due to abnormality in data transfer. 
Construct an interlock circuit in the sequence program. At the same time, determine the actions
in the system between the external equipment and the PLC (Master station contains) for
protection against abnormalities in data transfer.

Make sure to have the following safety circuits outside of the PLC to ensure safe system
operation even during external power supply problems or PLC failure.
Otherwise, malfunctions may cause serious accidents.
1) Most importantly, have the following: an emergency stop circuit, a protection circuit, an

interlock circuit for opposite movements (such as normal vs. reverse rotation), and an interlock
circuit (to prevent damage to the equipment at the upper and lower positioning limits).

2) Note that when the PLC CPU detects an error, such as a watchdog timer error, during self-

diagnosis, all outputs are turned off. Also, when an error that cannot be detected by the
PLC CPU occurs in an input/output control block, output control may be disabled.
External circuits and mechanisms should be designed to ensure safe machinery operation
in such a case.

1)

2)

A

  

3.1 Applicable PLC

The version number can be checked by monitoring the last three digits of D8001.

*1 An FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is necessary to connect the 64CCL with the

FX

3GC

/FX

3UC

 PLC.

*2 An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect the 64CCL with

the FX5U/FX5UC PLC.

3.2 General Specifications

Items other than the following are equivalent to those of the PLC main unit.
For general specifications, refer to the manual of the PLC main unit.

→ 

For details, refer to the FX

3G

 Series User's Manual - Hardware Edition.

→ 

For details, refer to the FX

3GC

 Series User's Manual - Hardware Edition.

→ 

For details, refer to the FX

3U

 Series User's Manual - Hardware Edition.

→ 

For details, refer to the FX

3UC

 Series User's Manual - Hardware Edition.

→ 

For details, refer to the MELSEC iQ-F FX5U User's Manual (Hardware).

→ 

For details, refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).

3.3 Power Supply Specification

3.4 Performance Specification

DESIGN
PRECAUTIONS

Make sure to observe the following precautions in order to prevent any damage to the
machinery or accidents due to abnormal data written to the PLC under the influence of noise:
1) Do not bundle the control line together with or lay it close to the main circuit or power line.

As a guideline, lay the control line at least 100 mm (3.94") or more away from the main
circuit or power line. Noise may cause malfunctions.

2) Ground the shield wire or shield of a shielded cable. Do not use common grounding with

heavy electrical systems.

Install module so that excessive force will not be applied to the power supply terminal block or
CC-Link connection terminal block. Failure to do so may result in wire damage/breakage or
PLC failure.

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the environmentally safe
recycling and disposal of your device.

TRANSPORTATION AND 
STORAGE PRECAUTIONS

The PLC is a precision instrument. During transportation, avoid impacts larger than those
specified in the general specifications of the PLC main unit manual by using dedicated
packaging boxes and shock-absorbing palettes.Failure to do so may cause failures in the PLC. 
After transportation, verify operation of the PLC and check for damage of the mounting part, etc.

Model name

Applicability

FX

3G

 Series PLC

Ver. 1.00 (from the first product) and later
Only one 64CCL unit can be connected in a main unit.

FX

3GC

 Series PLC

*1

Ver. 1.40 (from the first product) and later
Only one 64CCL unit can be connected in a main unit.

FX

3U

 Series PLC

Ver. 2.20 (from the first product) and later
Only one 64CCL unit can be connected in a main unit.

FX

3UC

 Series PLC

*1

Ver. 2.20 (from products manufactured in May, 2005 with
SER No. 55****) and later
Only one 64CCL unit can be connected in a main unit.

FX5U PLC

*2

Ver. 1.000 (from the first product) and later 
Only one 64CCL unit can be connected in a CPU module.

FX5UC PLC

*2

Ver. 1.000 (from the first product) and later
Only one 64CCL unit can be connected in a CPU module.

Item

Specification

Dielectric withstand voltage 500 V AC for one minute

Between all terminals and
ground terminal

Insulation resistance

5 M

 or higher by 500 V DC

insulation resistance tester

Item

Specification

External 
power 
supply

Power supply voltage

24 V DC +20% -15% Ripple (p-p) within 5%

Permitted instantaneous
power failure time

Operation continues when the instantaneous
power failure is shorter than PS1:1 ms.

Current consumption

220 mA

Internal 
power 
supply

Power supply voltage

5 V DC

Current consumption

5 V DC of PLC is not used. (5 V DC is converted
from 24 V DC external power supply.)
Make sure to observe the power-on timing
and the procedure.

Item

Specification

CC-Link applicable version

Ver.2.00 (Ver.1.10 also supported.)

*1

Station type

Intelligent device station

Station number

1 to 64

Transmission rate

156Kbps/625Kbps/2.5Mbps/5Mbps/10Mbps

*1 When the setting of the 64CCL is the single setting, please set up the

master station as a Ver.1 intelligent device station. When the setting of the
64CCL are the double setting, the quadruple setting, or the octuple setting,
please set up the master station as a Ver.2 intelligent device station.

Item

Specification

Transmission distance

In accordance with the CC-Link specification.
Refer to the PLC main unit manual for details.

Number of occupied stations

1 to 4 stations

Setting items

Station number, Transmission rate, Number of
occupied stations, Expanded cyclic setting

Connection cable

CC-Link dedicated cable/ 
CC-Link dedicated high-performance cable/ 
Ver.1.10 compatible CC-Link dedicated cable

Number of I/O occupied 
points

8 points

Number of connectable units
to the main unit

1

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品

 本产品中所含有的有害6 物质的名称,含有量,含有部品如下表

所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572

 规定的限量要求以下。 

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 
    26572规定的限量要求。

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

可编程
控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使用标识要求」的表示方式

基于中国标准法的参考规格:GB/T15969.2

FX

3U

-64CCL

INSTALLATION MANUAL

This manual describes the part names, dimensions, and specifications of the
product. Before use, read this manual and manuals of relevant products fully to
acquire proficiency in handling and operating the product. Make sure to learn all
the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.

Effective May 2018
Specifications are subject to change without notice.

©

 2008 Mitsubishi Electric Corporation

Manual Number

JY997D29801

Revision

F

Date

May 2018

Reviews: