6.3.2
High Speed Mode
When the calculation result (D0 + D2) in the master station is 100 or less, the Y010 in the slave station is turned on (
➀
). The
D10 value in the slave station is set to the timer (T0) in the master station (
➁
).
M8000
M8070
ADD
D0 D2 D490
M8000
X010
T0
D500
END
M8162
Master station
1
2
M8000
M8071
CMP D490 K100 M10
M8000
END
M8162
M10
Y010
X010
MOV D10 D500
Slave atation
1
2
6
FX
2N
-485-BD COMMUNICATION BOARD
PARALLEL LINK
6-4