6.3.2
Enable / EnableOutput (EN/ENO)
쎲
The EN input makes the function (or FB, see later), conditional (Switch On/Off)
쎲
The ENO reflects the status of the EN line.
쎲
Only instructions with or without EN should be used in a network, do not mix both types.
쎲
The EN/ENO chain should have all its pre-conditions at the beginning:
Function Definitions
쎲
All devices suffixed “_E” have EN / ENO lines, otherwise they do not.
쎲
All devices suffixed “_M” are manufacturers instructions, i.e. in this case from the relevant
Mitsubishi instruction set.
Exercise (Gated Operation)
Edit the Function Block STAR_DELTA to have an EN/ENO input/output feature. Drive the EN
(enable) input with external MELSEC X07 contact:
6 - 22
MITSUBISHI ELECTRIC
Functions and Function Blocks
Execution Options of Function Blocks
Summary of Contents for FX2N-32CAN
Page 1: ...MITSUBISHI ELECTRIC FACTORY AUTOMATION Programmable Logic Controllers GX IEC Developer ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ...IV MITSUBISHI ELECTRIC ...
Page 18: ...Modular PLC Training Hardware Course Overview and Requirements 1 2 MITSUBISHI ELECTRIC ...
Page 176: ...Device Edit 8 4 MITSUBISHI ELECTRIC ...
Page 190: ...Assigning DUT Variables to Function Blocks Data Unit Types DUT 10 10 MITSUBISHI ELECTRIC ...
Page 198: ...Array Example Single Dimension Array Arrays 11 8 MITSUBISHI ELECTRIC ...
Page 219: ...Sequential Function Chart SFC SFC Elements Training Manual GX IEC Developer 14 3 ...
Page 230: ...Structured Text Program Example IEC Structured Text 16 4 MITSUBISHI ELECTRIC ...
Page 278: ...PLC Components Glossary Appendix A 18 MITSUBISHI ELECTRIC ...
Page 283: ......