1
1 INSTALLATION AND INSTRUCTIONS
1.2 Installation of the inverter
Installation on the panel
Notes
앫
It is not necessary to leave spaces on both sides of the inverter FR-F746.
앫
Some inverter models may be installed outside an enclosure. See Appendix A.2 for details.
FR-F740-00126-EC
LD (50 C) XXA
SLD (40 C) XXA
1.1 Inverter Type
Symbol
Voltage Class
F740
Three-phase 400V class
Symbol
Type number
00023
to
12120
Displays the
rated current
Capacity plate example
Rating plate example
Inverter type Serial number
Inverter type
Input rating
Output rating
Serial number
Overload current rating Ambient temperature
LD
120% 60s, 150% 3s
50°C
SLD
110% 60s, 120% 3s
40°C
Symbol
Voltage Class
F746
Three-phase 400V class/
waterproof structure IP54
(standard IEC 60529:
2001) specification
Symbol
Type number
00023
to
01160
Displays the
rated current
Production year-month
00023 to 00620
00770 to 12120
Fix six positions for the FR-F740-04320 to 08660 and
fix eight positions for the FR-F740-09620 to 12120.
CAUTION
앫
When encasing multiple inverters, install them in parallel
and leave clearance as a cooling measure.
Y
Y
X
Inverter Capacity
X [cm]
Y [cm]
≤
00083
≥
1
≥
10
00126–01160
≥
5
≥
01800
≥
10
≥
20