63
Param
e
te
r List
Parameter list
4
4.2 Parameter list
4.2.1
Parameter list
In the initial setting, only the simple mode parameters are displayed.
Set
Pr. 160 User group read selection
as required.
Parameter
Name
Initial
Value
Setting
Range
Remarks
160
User group read
selection
9999
9999
Only the simple mode parameters can be displayed.
0
Simple mode and extended mode parameters can be
displayed.
1
Only the parameters registered in the user group can be
displayed.
REMARKS
⋅
The parameters marked
are the simple mode parameters.
⋅
The parameters marked with
in the table allow its setting to be changed during operation even if "0" (initial
value) is set in
Pr. 77 Parameter write selection
.
⋅
Refer to the appendix 2
(page 314)
for instruction codes for communication and availability of parameter clear, all clear, and
parameter copy of each parameter.
⋅
Parameters with
have different specifications according to the date assembled. Refer to
page
to check the
SERIAL number.
Function Parameters
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Ba
si
c f
un
ct
io
ns
0
Torque boost
0 to 30%
0.1%
6/4/3/2/
1.5/1%
1
Maximum frequency
0 to 120Hz
0.01Hz
120/60Hz
2
Minimum frequency
0 to 120Hz
0.01Hz
0Hz
3
Base frequency
0 to 400Hz
0.01Hz
60Hz
4
Multi-speed setting (high speed)
0 to 400Hz
0.01Hz
60Hz
5
Multi-speed setting (middle speed)
0 to 400Hz
0.01Hz
30Hz
6
Multi-speed setting (low speed)
0 to 400Hz
0.01Hz
10Hz
7
Acceleration time
0 to 3600/ 360s
0.1/0.01s
5s/15s
8
Deceleration time
0 to 3600/ 360s
0.1/0.01s
10s/30s
9
Electronic thermal O/L relay
0 to 500/0 to 3600A
0.01/0.1A
Rated
inverter
current
DC in
je
ct
io
n
br
ak
e
10
DC injection brake operation
frequency
0 to 120Hz, 9999
0.01Hz
3Hz
11
DC injection brake operation time
0 to 10s
0.1s
0.5s
12
DC injection brake operation voltage
0 to 30%
0.1%
4/2/1%
⎯
13
Starting frequency
0 to 60Hz
0.01Hz
0.5Hz
⎯
14
Load pattern selection
0, 1
1
1
Jo
g
op
er
at
io
n
15
Jog frequency
0 to 400Hz
0.01Hz
5Hz
16
Jog acceleration/deceleration time
0 to 3600/360s
0.1/0.01s
0.5s
⎯
17
MRS input selection
0, 2
1
0
⎯
18
High speed maximum frequency
120 to 400Hz
0.01Hz
120/60Hz
⎯
19
Base frequency voltage
0 to 1000V, 8888, 9999
0.1V
9999