4.22.7 Setting multiple parameters as a batch (Pr.999)
(1)
Automatic parameter setting (Pr.999)
Select which parameters to be automatically set, and set that to
Pr. 999
. Multiple parameter settings are changed
automatically.
Refer to page 276
for the list of parameters that are changed automatically.
Parameter settings are changed as a batch. Those include communication parameter settings for the Mitsubishi
human machine interface (GOT) connection and rated frequency settings of 50Hz/60Hz.
Multiple parameters are changed automatically. Users do not have to consider each parameter number. (Parameter
setting mode)
Parameter
Number
Name
Initial value
Setting range
Description
999
Automatic parameter setting
9999
10
GOT initial setting (PU connector)
20
50Hz rated frequency
21
60Hz rated frequency
9999
No action
The read value is always
"
9999
"
.
Pr.999 setting
Description
Operation in the parameter setting
mode
10
Automatically sets the communication parameters for the GOT
connection with a PU connector
(AUTO)
(GOT)
Write "1"
20
50Hz rated
frequency
Sets the related parameters of the rated
frequency according to the power supply
frequency
(AUTO)
(F50)
Write "1"
21
60Hz rated
frequency
—
REMARKS
If the automatic setting is performed, the selected settings including the changed parameter settings will be changed.
Setting
Pr. 999
= "20 or 21" during the machine speed display changes the
Pr. 505 Speed setting reference
setting to 60Hz or to
50Hz. After setting
Pr. 999
= "20 or 21", calculate the rotations per minute at the changed
Pr. 505
setting, and set
Pr. 37 Speed
display
again.