8. (E) Environment Setting Parameters
8.18 Current average value monitor signal
1
2
3
4
5
6
7
8
9
10
8.18
Current average value monitor signal
The output current average value during constant-speed operation and the maintenance timer value are output to the Current
average monitor (Y93) signal as a pulse. The output pulse width can be used in a device such as the I/O unit of a programmable
controller as a guideline for the maintenance time for mechanical wear, belt stretching, or deterioration of devices with age.
The pulse is repeatedly output during constant-speed operation in cycles of 20 seconds to the Current average monitor (Y93)
signal.
Operation example
• The pulse output of the Current average monitor (Y93) signal is indicated below.
• For the terminal used for the Y93 signal output, assign the function by setting "93" (positive logic) or "193" (negative logic)
in any parameter of
Pr.190, Pr.191, Pr.193 to Pr.196 (Output terminal function selection)
. (This cannot be assigned by
setting in
Pr.192 ABC terminal function selection
.)
Pr.556 Data output mask time setting
• Immediately after acceleration/deceleration is shifted to constant-speed operation, the output current is unstable
(transitional state). Set the time for not obtaining (masking) transitional state data in
Pr.556
.
Programmable controller
Output
unit
Input
unit
maintenance
time
parts have
reached their life
Inverter
Pr.
Name
Initial value
Setting range
Description
555
E720
Current average time
1 s
0.1 to 1 s
Set the time for calculating the average current during start
pulse output (1 second).
556
E721
Data output mask time
0 s
0 to 20 s
Set the time for not obtaining (masking) transitional state
data.
557
E722
Current average value
monitor signal output
reference current
Inverter rated
current
0 to 500 A
Set the reference (100%) for outputting the output current
average value signal.
Y93 signal
Data output mask time
Start pulse
1 cycle (20 s)
Output current average value pulse
Next cycle
Time
Output
frequency
From acceleration to constant speed operation
Maintenance timer pulse
End pulse
The averaged current value is output as low pulse shape for
0.5 to 9 s (10 to 180%) during start pulse output.
When the speed has changed to constant
from acceleration/deceleration, Y93 signal is
not output for
Pr. 556
time.
Signal output time=
output current average value (A)
Pr. 557
(A)
5 s
Signal output time=
5 s
40000h
Pr. 503
100h
output as low pulse
shape for 1 to 16.5 s
The maintenance timer value (
Pr. 503
) is output
as Hi output pulse shape for 2 to 9 s (16000h to
72000h).
Output as Hi pulse shape for 1 s (fixed)
The output currents are averaged during the time
period set in
Pr.555
.
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...