Communication connectors and terminals
55
2
2.8.2
PU connector
Installing the operation panel on the enclosure surface
• Having an operation panel on the enclosure surface is convenient. With a connection cable, you can install the operation
panel on the enclosure surface, and connect it to the converter unit.
Use the option FR-CB2[ ], or connectors and cables available on the market.
(To install the operation panel, the optional connector (FR-ADP) is required. )
Securely insert one end of the connection cable until the stoppers are fixed.
NOTE
• Refer to the following table when fabricating the cable on the user side. Keep the total cable length within 20 m.
• Commercially available products (as of February 2015)
Communication operation
• Using the PU connector enables communication operation from a personal computer, etc. When the PU connector is
connected with a personal, FA or other computer by a communication cable, a user program can run to monitor the
converter unit or read and write parameters.
Communication can be performed with the Mitsubishi inverter protocol (computer link operation).
For the details, refer to
.
Name
Remarks
Communication cable
Cable compliant with EIA-568 (such as 10BASE-T cable)
Parameter unit connection cable
(FR-CB2[ ]) (option)
Operation panel
connection connector
(FR-ADP) (option)
Operation panel
(FR-DU08)