Control circuit
48
NICHIFU Co., Ltd.
NOTE
• When using stranded wires without a blade terminal, twist enough to avoid short circuit with a nearby terminals or wires.
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause a converter unit
damage or injury.
• Wire removal
Common terminals of the control circuit (SD, PC, SE)
• Terminals SD (sink logic), PC (source logic), and SE are common terminals (0 V) for I/O signals. (All common terminals are
isolated from each other.) Do not earth (ground) these terminals.
• In the sink logic, terminal SD is a common terminal for the contact input terminals (RES, OH, RDI). The open collector
circuit is isolated from the internal control circuit by photocoupler.
• In the source logic, terminal PC is a common terminal for the contact input terminals (RES, OH, RDI). The open collector
circuit is isolated from the internal control circuit by photocoupler.
• Terminal SE is a common terminal for the open collector output terminals (RDA, RDB, RSO, IPF, FAN). The contact input
circuit is isolated from the internal control circuit by photocoupler.
A ferrule terminal with an insulation sleeve compatible with the MTW wire which has a thick wire insulation.
Applicable for terminals A1, B1, C1, A2, B2, and C2 only.
Cable gauge (mm
2
)
Blade terminal product number
Insulation cap product
number
Crimping tool
product number
0.3 to 0.75
BT 0.75-11
VC 0.75
NH 69
(3) Insert the wires into a socket.
When using a single wire or stranded wires without a blade terminal, push the
open/close button all the way down with a flathead screwdriver, and insert the
wire.
Pull the wire while pushing the open/close button all
the way down firmly with a flathead screwdriver.
Cable gauge (mm
2
)
Ferrule terminal model
Crimping tool
name
With insulation sleeve
Without insulation sleeve
For UL wire
Flathead screwdriver
Open/close button
Flathead screwdriver
Open/close button
NOTE
• Pulling out the wire forcefully without pushing the open/close
button all the way down may damage the terminal block.
• Use a small flathead screwdriver (tip thickness: 0.4 mm/tip
width: 2.5 mm).
If a flathead screwdriver with a narrow tip is used, terminal
block may be damaged.
Commercially available products (as of October 2020)
• Place the flathead screwdriver vertical to the open/close
button. In case the blade tip slips, it may cause a converter
unit damage or injury.
Name
Model
Manufacturer
Driver
SZF
0- 0,4
2,5
Phoenix Contact Co., Ltd.