84
Start/stop from the operation panel (PU
4.4.2
Use the setting dial like a potentiometer to perform operation.
POINT
Set "1" (setting dial potentiometer mode) in
Pr. 161 Frequency setting/key lock operation selection
.
Operation example Change the frequency from 0Hz to 60Hz during operation
REMARKS
· If flickering "60.00" turns to "0.0", the
Pr. 161 Frequency setting/key lock operation selection
setting may not be "1".
· Independently of whether the inverter is running or at a stop, the frequency can be set by merely turning
.
Display
Operation
PU indication is lit.
1.
Screen at powering on
The monitor display appears.
2.
Press to choose PU operation mode.
3.
Change
Pr. 161
to the setting value " ".
4.
Press (or ) to start the inverter.
5.
Turn until " " appears.
The flickering frequency is the set frequency.
You need not press .
The frequency flickers for about 5s.
60.00
(Refer to page 52 for change of the setting.)
Summary of Contents for FR-A741-11K
Page 7: ...MEMO ...
Page 216: ...209 MEMO ...