6 PARAMETER
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel. For details of parameters, refer to the instruction manual.
In the initial setting, all parameters are displayed. Set
Pr. 160 Extended function display selection
as required.
Parameter
Name
Initial
Value
Setting
Range
Remarks
160
User group read selection
0
9999
Only the simple mode parameters can be displayed.
0
Simple mode and extended mode parameters can be
displayed.
1
Only parameters registered in the user group can be displayed.
Remarks
The parameters marked
are the simple mode parameters.
The parameters marked with
in the table allow its setting to be changed during operation even if "0"
(initial value) is set in
Pr. 77 Parameter write selection
.
Parameter
Name
Setting Range
Initial Value
0
Torque boost
0 to 30%
3/2% *
1
1
Maximum frequency
0 to 120Hz
120Hz
2
Minimum frequency
0 to 120Hz
0Hz
3
Base frequency
0 to 400Hz
60Hz
4
Multi-speed setting
(high speed)
0 to 400Hz
60Hz
5
Multi-speed setting
(middle speed)
0 to 400Hz
30Hz
6
Multi-speed setting
(low speed)
0 to 400Hz
10Hz
7
Acceleration time
0 to 3600/360s
5s/15s *
1
8
Deceleration time
0 to 3600/360s
5s/15s *
1
9
Electronic thermal
O/L relay
0 to 500A
Rated
inverter
output
current
10
DC injection brake
operation frequency
0 to 120Hz,
9999
3Hz
11
DC injection brake
operation time
0 to 10s, 8888
0.5s
12
DC injection brake
operation voltage
0 to 30%
4/2% *
1
13
Starting frequency
0 to 60Hz
0.5Hz
14
Load pattern selection
0 to 5
0
15
Jog frequency
0 to 400Hz
5Hz
16
Jog acceleration/
deceleration time
0 to 3600/360s
0.5s
17
MRS input selection
0, 2, 4
0
18
High speed maximum
frequency
120 to 400Hz
120Hz
19
Base frequency
voltage
0 to 1000V,
8888, 9999
9999
20
Acceleration/
deceleration reference
frequency
1 to 400Hz
60Hz
21
Acceleration/
deceleration time
increments
0, 1
0
22
Stall prevention
operation level
(torque limit level )
0 to 400%
150%
23
Stall prevention
operation level
compensation factor
at double speed
0 to 200%, 9999
9999
24–27
Multi-speed setting 4
speed to 7 speed
0 to 400Hz,
9999
9999
28
Multi-speed input
compensation
selection
0, 1
0
29
Acceleration/
deceleration pattern
selection
0 to 5
0
31
Frequency jump 1A
0 to 400Hz,
9999
9999
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
0, 1 to 9998
0
41
Up-to-frequency
sensitivity
0 to 100%
10%
42
Output frequency
detection
0 to 400Hz
6Hz
43
Output frequency
detection for reverse
rotation
0 to 400Hz,
9999
9999
44
Second acceleration/
deceleration time
0 to 3600/360s
5s
45
Second deceleration
time
0 to 3600/360s,
9999
9999
46
Second torque boost
0 to 30%, 9999
9999
47
Second V/F (base
frequency)
0 to 400Hz,
9999
9999
48
Second stall
prevention operation
current
0 to 220%
150%
49
Second stall
prevention operation
frequency
0 to 400Hz,
9999
0Hz
Parameter
Name
Setting Range
Initial Value