526
SELECTION
3.6 Selection of peripheral devices
The moulded case circuit breakers, magnetic contactors and cables differ with the inverter models.
For specific selection, refer to the corresponding model catalog or manual.
Peripheral device selection list (example
)
Vo
lta
ge
Motor
Output
(kW)
*1
Applied
Inverter
Type
Moulded Case Circuit Breaker (MCCB)
*2
or Earth Leakage Circuit Breaker (ELB)
Magnetic contactor on
the Input Side
*3
Recommended
Cable Size
(mm
2
)
*4
Reactor connection
Reactor connection
R, S, T U, V, W
Without
With
Without
With
200V class
0.4
FR-A720-0.4K
30AF 5A
30AF 5A
S-N10
S-N10
2
2
0.75
FR-A720-0.75K 30AF 10A
30AF 10A
S-N10
S-N10
2
2
1.5
FR-A720-1.5K
30AF 15A
30AF 15A
S-N10
S-N10
2
2
2.2
FR-A720-2.2K
30AF 20A
30AF 15A
S-N10
S-N10
2
2
3.7
FR-A720-3.7K
30AF 30A
30AF 30A
S-N20,
N21
S-N10
3.5
3.5
5.5
FR-A720-5.5K
50AF 50A
50AF 40A
S-N25
S-N20,
N21
5.5
5.5
7.5
FR-A720-7.5K
100AF 60A
50AF 50A
S-N25
S-N25
14
8
11
FR-A720-11K
100AF 75A
100AF 75A
S-N35
S-N35
14
14
15
FR-A720-15K
225AF 125A
100AF 100A
S-N50
S-N50
22
22
18.5
FR-A720-18.5K 225AF 150A
225AF 125A
S-N65
S-N50
38
38
22
FR-A720-22K
225AF 175A
225AF 150A
S-N80
S-N65
38
38
30
FR-A720-30K
225AF 225A
225AF 175A
S-N95
S-N80
60
60
37
FR-A720-37K
400AF 250A
225AF 225A
S-N150
S-N125
80
80
45
FR-A720-45K
400AF 300A
400AF 300A
S-N180
S-N150
100
100
55
FR-A720-55K
400AF 400A
400AF 350A
S-N220
S-N180
100
100
75
FR-A720-75K
—
400AF 400A
—
S-N300
125
125
90
FR-A720-90K
—
400AF 400A
—
S-N300
150
150
A700