2.3 Operation mode
2.3.1
Operation mode selection [Pr. 79]
(common)
The operation mode specifies the source of the start
command and the frequency command for the inverter.
Basically, there are following operation modes.
y
External operation mode: For inputting start command
and frequency command with an external potentiometer
and switches which are connected to the control circuit
terminal.
y
PU operation mode: For inputting start command and
frequency command with the operation panel (FR-DU07
/ FR-PA07), parameter unit (FR-PU04 / FR-PU07), or
RS-485 communication
*4
using PU connector.
y
Network operation mode (NET operation mode): For
inputting start command and frequency command with
RS-485 terminal
*2
or communication option
*3
.
The operation mode can be selected from the operation
panel or with the communication instruction code.
The operation mode is factory-set to allow the "PU
operation" or "External operation mode" to be selected by
using
and the "External operation mode" at power
on.
Refer to page 434 for the "Network operation mode".
*1
B connector for
, and mini B connector for
and
do not have USB connector.
*2
and
do not have RS-485 terminal.
*3
Built-in option is not available for
.
*4
For
and
, change to Network operation mode
for RS-485 communication with PU connector.
common
1
2
3
4
5 6
7
8
9
10
Network operation mode
Network operation
mode
External
operation
mode
PU operation
mode
Personal
computer
Personal
computer
Operation
panel
Programmable controller
Potentiometer Switch
RS-485
terminals
*2
Inverter
Communication
option
External terminal
Personal
computer
USB
connector
*1
PU connector
*3
*4
A700
E700
F700
D700
E700
D700
D700
E700
D700
[Pr. ] Name
Initial
Value
Setting
Range
Description
PU Operation
External Operation
Remarks
Frequency
command
Start
command
Frequency
command
Start
command
79
Operation
mode
selection
0
0
External/PU switching mode
(at powering ON)
Switch with
1
Fixed to PU operation mode
2
Fixed to External operation
mode
3
External/PU combined
operation mode 1
4
External/PU combined
operation mode 2
6
Switchover mode
(at powering ON)
Switching is enabled while
running
7
PU operation interlock
(at powering ON)
External operation can be
fixed with X12 signal
0, 6, 7
X16 signal External/PU
switching mode
Operation mode can be
switched with X16 signal