Operation panel FR-DU07
Operation
4 - 14
4.3.11 Parameter
copy
Multiple inverters and parameter settings can be copied.
I001115E
Fig. 4-11:
Parameter copy
Connect the operation panel to the copy source
inverter.
Connect it during a stop.
Press the MODE key to choose the parameter
setting mode.
Turn the digital dial until "PCPY" (parameter
copy) appears.
Press the SET key to show the currently set value.
The initial value "0" appears.
Turn the digital dial to change it to the setting
value of "1".
Press the SET key to copy the source parameters
to the operation panel.
Connect the the operation panel to the copy
destination inverter. Check that Pr. 77 of the
destination inverter is not set to disable parameter
writing.
Perform steps
to
again. Turn the digital dial
clockwise until "2" appears.
Press the SET key to write the parameters copied
to the operation panel to the destination inverter.
When copy is completed, "2" and "PCPY" flicker.
After writing the parameter values to the copy
destination inverter, always reset the inverter,
e.g. switch power off once, before starting
operation.
Operation
Display
The parameter number
read previously
appears.
Flicker ... Parameter copy complete!
The value flickers
for about 30s.
About 30s later
The value flickers
for about 30s.
About 30s later
Flicker ... Parameter copy complete!
Summary of Contents for FR-A700 EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Page 38: ...Enclosure design Installation 2 14 ...
Page 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Page 820: ...Parameter list with instruction codes Appendix A 50 ...
Page 825: ......