53
Regeneration avoidance function
(Pr. 882)
3.11 Regeneration avoidance function
(Pr. 882)
This function detects a regeneration status and increases the frequency to avoid the regeneration status.
Setting
Pr. 882
= "1 to 3" enables the regeneration avoidance function.
Setting the parameter to "3" enables the regeneration avoidance function during normal operation, and disables the
function during deceleration-to-a-stop operation initiated by turn-OFF of the start signal. In this way, the machine can be
stopped quickly by using the regenerative braking equipment.
3.12 Operation command source and speed command source
(Pr. 338, Pr. 339)
In the Network operation mode, commands from the external terminals and network are as listed below.
(Different signals can be assigned with the input terminal function selection. )
Parameter
Number
Name
Setting
Range
Increments
Initial
Value
Remarks
882
Regeneration avoidance
operation selection
0 to 3
1
0
0: Regeneration avoidance function disabled
1: Always enabled
2: Enabled only at constant speed operation
3: Enabled only while start signal is ON
Parameter
Number
Name
Setting
Range
Increments
Initial
Value
Remarks
338
Communication operation
command source
0, 1
1
0
0: Command source is NET
1: Command source is external terminal
339
Communication speed
command source
0 to 2
1
0
0: Command source is NET
1: Command source is external terminal 1
2: Command source is external terminal 2
Operation
Location
Selection
Pr. 338
Communication operation command source
0: NET
1: External
Remarks
Pr. 339
Communication speed command source
0 : NET
1:
External
2:
External
0 : NET
1:
External
2:
External
Fixed
function
(terminal-
equivalent
function)
Running frequency from communication
NET
—
NET
NET
—
NET
Terminal 2
—
External
—
—
External
—
Terminal 4
—
External
—
External
Terminal 1 (dancer roll position detection)
External
*
Sel
e
ct
iv
e f
u
nct
io
n
P
r.1
78
to
P
r.
18
9
se
tt
in
g
0
RL
Low-speed operation command/remote
setting clear
NET
External
NET
External
Pr.59 =
"0"
(Multi-speed)
Pr.59 =
"1,2"
(Remote)
1
RM
Middle-speed operation command/
remote set deceleration
NET
External
NET
External
2
RH
High-speed operation command/
remote set acceleration
NET
External
NET
External
3
RT
Second function selection
NET
External
4
AU
Current input selection
—
Combined
—
Combined
5
JOG Jog operation selection
—
External
6
CS
Selection of automatic restart after
instantaneous power failure
External
7
OH
External thermal relay input
External
8
REX 15-speed selection
NET
External
NET
External
Pr.59
="0"
(Multi-speed)
9
X9
Third function selection
NET
External
10
X10 Inverter run enable signal
External
11
X11
FR-HC connection, instantaneous
power failure detection
External
12
X12 PU operation external interlock
External
13
X13 External DC injection brake operation start
NET
External
14
X14 PID control valid terminal
NET
External
NET
External
16
X16 PU-External operation switchover
External
17
X17
Load pattern selection forward rotation
reverse rotation boost
NET
External
18
X18 V/F switchover
NET
External
20
X20
S-pattern acceleration/deceleration C
switching terminal
NET
External
22
X22 Orientation command
NET
External
23
LX
Pre-excitation
NET
External