Graphic Operation Terminal F930GOT
Screen Mode 3
3-7
3.3.2
When SW
o
o
o
o
D5C-GOTR-PACK is used
1) Completion flag
When a screen is created using the SW
o
D5C-GOTRE-PACK, the system information
(described in Paragraph 8.6.2) write device D
¡
+4 b3 becomes ON as the completion flag.
System information
•
D
¡
+4 b3
"
¡
" indicates the head write device No.
Operation
•
When "Project Unit" in "Auxiliary Setting" in "Common Setting" in the screen creation soft-
ware is set so that the key window is open and the ENT key is pressed on the ten-key win-
dow, the flag becomes ON.
•
While the touch key code is set to "000D", the flag becomes ON when the touch key is
pressed.
•
Once the completion flag becomes ON, it remains ON. To set it to OFF, execute the RST
(reset) instruction in a sequence program.
2) User ID
The user ID can be assigned to each "Numerical Input" and "Ascii Input" using the screen
creation software.
The user can set arbitrarily the user ID within the range of 1 to 65535.
The user ID is written to the following device in the PLC.
System information
•
D
¡
+3
"
¡
" indicates the head write device No.
By checking the current value of D
¡
+3, the user can know which "Numerical Input/Ascii
Input" has been changed.
Summary of Contents for F930GOT-BWD-E
Page 1: ...USER S MANUAL F930GOT BWD E ...
Page 4: ...Graphic Operation Terminal F930GOT ii ...
Page 6: ...Graphic Operation Terminal F930GOT iv ...
Page 14: ...vi ...
Page 60: ...Graphic Operation Terminal F930GOT Start up 2 2 10 MEMO ...
Page 68: ...Graphic Operation Terminal F930GOT Screen Mode 3 3 8 MEMO ...
Page 120: ...Graphic Operation Terminal F930GOT Creation of Display Screens 8 8 30 ...
Page 200: ...Graphic Operation Terminal F930GOT Changeover of Display Screen FX PCS DU WIN E 10 10 18 ...
Page 272: ...Graphic Operation Terminal F930GOT Additional Functions in V 2 00 or later 13 13 24 MEMO ...