Graphic Operation Terminal F930GOT
Additional Functions (in V.2.00 or later) 13
13-2
13.2
Connection of bar code reader
13.2.1
Connection
* A bar code reader is connected to the RS-232C connector. Accordingly, the printout function
or the two-port interface function cannot be used together with a bar code reader.
If the F930GOT is connected to the PLC via RS-232C, the bar code reader connection func-
tion is not available.
13.2.2
Communication specifications
The F930GOT can be connected to a bar code reader which satisfies the communication
specifications and the communication format shown below.
•
Communication specifications
•
Communication format
Data
: ASCII code
Header
: None
End code : CR (0DH)
Communication port
RS232C
Baud rate
9600 bps
Data length
8 bits
Stop bit length
1 bit
Parity
Even
Data
CR (0DH)
5
4
3
2
1
9
8
7
6
9:
1:Unused
2:RD(RXD)
3:SD(TXD)
4:DTR
5:SG
6:DSR
7:RTS
8:CTS
•
System configuration
•
Connection
F930GOT: RS-232C connector
Summary of Contents for F930GOT-BWD-E
Page 1: ...USER S MANUAL F930GOT BWD E ...
Page 4: ...Graphic Operation Terminal F930GOT ii ...
Page 6: ...Graphic Operation Terminal F930GOT iv ...
Page 14: ...vi ...
Page 60: ...Graphic Operation Terminal F930GOT Start up 2 2 10 MEMO ...
Page 68: ...Graphic Operation Terminal F930GOT Screen Mode 3 3 8 MEMO ...
Page 120: ...Graphic Operation Terminal F930GOT Creation of Display Screens 8 8 30 ...
Page 200: ...Graphic Operation Terminal F930GOT Changeover of Display Screen FX PCS DU WIN E 10 10 18 ...
Page 272: ...Graphic Operation Terminal F930GOT Additional Functions in V 2 00 or later 13 13 24 MEMO ...