GOT-F900 SERIES (CONNECTION)
Connection of FREQROL (S500/E500/A500) Inverter 13
13-25
11
C
o
n
n
e
c
ti
on
of
ME
L
S
E
C
-Q
Se
ri
e
s
PL
C
12
Co
n
n
e
c
ti
o
n
o
f
FX Se
ri
e
s
Po
s
it
io
n
in
g
13
C
o
n
n
e
c
ti
on o
f
FR
EQ
R
O
L
In
ve
rt
er
14
C
onn
ec
ti
o
n
of
Mi
cr
o
c
o
m
-
put
e
r
15
C
o
nn
ec
ti
o
n
of
S
YSM
A
C
C
Se
ri
e
s
PL
C
16
C
o
nne
c
ti
o
n of
F
L
EX-
PC N
Se
ri
e
s
PL
C
17
C
o
nn
ect
io
n o
f
M
a
c
h
in
e
C
on-
troll
e
r
18
C
o
nn
ec
ti
o
n
of
FP
Se
ri
e
s
PL
C
19
C
o
n
n
e
c
ti
on o
f
S
L
C
500
Se
ri
e
s
PLC
20
C
o
n
n
e
c
ti
on
of
SI
M
A
T
IC S7
Se
ri
e
s
PLC
13.6.2
Communication Parameters
The parameters shown in the table below correspond to the following communication ports respectively.
-
In the A500 Series, the following parameters are communication parameters for the FR-A5NR
computer link option.
-
In the E500 Series, only the PU port is available.
-
In the S500 Series, the following parameters are available if the RS-485 communication function
is provided.
If an inverter is connected to the PU port other than above, set the parameters using Pr. 117 to Pr. 124
shown in the previous page.)
Func-
tion
A500
E500
S500
Pr
Name
Pr
Name
Pr
Name
Computer link functio
n
331
Inverter station number
n1
331
Inverter station number
332
Communication speed
n2
332
Communication speed
333
Stop bit length
n3
333
Stop bit length
334
Parity check yes/no
n4
334
Parity check yes/no
335
Communication retry count
n5
335
Communication retry count
336
Communication check time interval
n6
336
Communication check time interval
337
Waiting time setting
n7
337
Waiting time setting
338
Operation command right
n8
338
Operation command right
339
Speed command right
n9
339
Speed command right
340
Link start mode selection
n10
340
Link start mode selection
341
CR•E LF yes/no selection
n11
341
CR•E LF yes/no selection
342
E
2
PROM write selection
n12
342
E
2
PROM write selection
−
−
n13
145
PU display language
−
−
n14
990
PU buzzer sound control
−
−
n15
991
PU contrast adjustment
−
−
n16
992
PU main display screen data selection
−
−
n17
993
PU disconnection detection/PU setting
lock
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......