
Connection of MELSEC-F FX Series PLC 8
8-1
1
In
tr
o
d
u
c
tio
n
2
Ou
tl
in
e
3
S
p
eci
fic
a
ti
on
s
4
in
st
a
ll
a
ti
o
n
an
d W
iri
ng
o
f
F9
40
G
O
T
5
in
s
ta
llat
io
n
an
d W
ir
in
g
of
Ha
n
d
y
GO
T
6
C
o
nne
c
ti
o
n o
f
P
e
ri
ph
er
al
Eq
ui
pm
en
t
7
C
o
nn
ect
io
n of
T
w
o or
Mor
e
GO
T
U
n
it
s
8
Co
n
n
e
c
ti
o
n
o
f
M
E
LSEC-
F
F
X
Se
ri
e
s
PLC
9
C
o
n
n
e
c
ti
on of
M
E
L
SEC-
A
Se
ri
e
s
PLC
10
C
onn
ec
ti
o
n
of
M
E
L
SEC-
Q
n
A
Se
ri
e
s
PLC
8.
Connection of MELSEC-F FX Series PLC
This chapter explains connection of the GOT-F900 Series display unit to the FX Series PLC.
Connection Procedure
This section introduces the procedure to connect the GOT-F900 to the FX Series PLC.
1.
Preparation
2.
Setting
3.
Others
8.1
System Condition
When connecting the FX Series PLC, check the COM port designation, the OS version of the GOT-
F900, and the applicable version of the screen creation software.
Compatibility when connecting FX Series PLC
- "RS-232C" in the "COM port" column may not be available in some FX Series PLC. Refer to section 3.1.
- The screen creation software version corresponds to the model of the GOT-F900 Series. Refer to section 3.2.
*1 The RS-232C port for the Handy type GOT is provided inside the rear cover. As a result, environmental
protection is lost when using this port and such a connection is not practical. (The Handy GOT can be
connected as the final unit in a string of two or more GOTs.)
Item name
Description
Reference
System Condition
You can learn the connection availability as well as the version of the
GOT-F900 OS and the screen creation software.
8.1
System Configuration
You can select the configuration between the GOT and the FX Series
PLC and proper cables.
8.2
Item name
Description
Reference
FXCPU Selection in
Direct Connection
When FXCPU connection is selected, the GOT-F900 is automatically set
to fixed values. No setting is required in the FX Series PLC.
−
Cautions on Use of
MELSEC-F FX Series
You can learn the restrictions in connecting the GOT to the FX Series
PLC.
8.3
Setting of Connected
Equipment for GOT
Set the PLC type using the GOT or the screen creation software.
8.4
Item name
Description
Reference
Cable Diagram
Cable diagrams for FX Series PLC/GOT connection.
8.5
Troubleshooting
Description of errors and how to fix them
8.6
GOT-F900
Series
COM port
Connection type
OS version
of GOT-F900
Version of screen creation
software
RS-422
RS-232C 1:1
Two or more
GOT units
GT
Designer2
GT
Designer
DU/WIN
F920GOT-K(5V)
$
−
$
−
1.00
SW1-C
SW5-26C
2.70
F920GOT-K(24V)
$
$
$
−
1.20
SW1-C
−
−
F930GOT
$
$
$
$
1.00
SW1-C
SW1-H
2.20
F930GOT-K
$
$
$
$
4.60
SW1-C
SW5-26C
2.70
F940GOT
$
$
$
$
1.00
SW1-C
SW1-A
2.00
F940WGOT
$
$
$
$
1.00
SW1-C
SW5-F
2.50
F940 Handy GOT
$
−
$
−
*1
1.00
SW1-C
SW1-D
2.10
F943 Handy GOT
−
$
$
−
*1
1.00
SW1-C
SW1-D
2.10
GOT-F900 SERIES (CONNECTION)
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......