GOT-F900 SERIES (CONNECTION)
Installation and Wiring of Handy GOT 5
5-34
5.9
Wiring and Handling of Operation Switches SW1 to SW4
This section explains the wiring and the use of the operation switches and the grip switch as well as
control of the LEDs for confirming pressing of the switches.
5.9.1
Handling of operation switches
This section explains the use of the operation switches and control of the LEDs for confirming pressing
of the switches.
The switches should be wired by the user. LED indication is executed through communication.
1) Wiring the operation switches
The operation switches are assigned as follows, and connected to the PLC through an external
cable.
Connection example
Pin layout
In the wire colors of the F9GT-HCAB1-
"
M, the indication "Color 1/Color 2" indicates striped two
colors.
2) Input of operation switches
Use the operation switches of the Handy GOT as follows.
How to use the operation switches
Because the operation switches SW1 to SW4 are directly connected to inputs of the PLC, they can
be controlled freely by programs in the PLC in the same way as general inputs.
-
An operation switch is taken into the PLC as a momentary type switch with N/O contact.
-
When you would like to treat input of an operation switch as N/C contact or an alternate type
switch, create a proper program in the PLC.
Signal name
External cable
Conversion box
F9GT-HCAB-
"
"
"
"
M
F9GT-HCAB1-
"
"
"
"
M
F9GT-RHCAB-
"
"
"
"
M
F9GT-HCNB
SW-COM
14
Fresh green
12
SWCOM
SW1
15
Sky blue
13
SW1
SW2
16
Black/white
14
SW2
SW3
17
Red/white
15
SW3
SW4
18
Green/white
16
SW4
P L C
c o m m o n
0 V
X 0
X 1
X 2
1 6
1 5
1 4
X 4
X 3
X 5
S W 1
S W
1 8
1 7
S W 2
S W 3
S W 4
H a n d y G O T
X0
Y0
Example:
When a switch is wired to X0 of the PLC
ON
OFF
ON
OFF
Operation of
operation switch
X0
Summary of Contents for F920GOT-BBD-K-E
Page 4: ...GOT F900 SERIES CONNECTION ii ...
Page 6: ...GOT F900 SERIES CONNECTION iv ...
Page 38: ...GOT F900 SERIES CONNECTION Outline 2 2 10 MEMO ...
Page 70: ...GOT F900 SERIES CONNECTION Specifications 3 3 32 MEMO ...
Page 230: ...GOT F900 SERIES CONNECTION Connection of MELSEC F FX Series PLC 8 8 26 MEMO ...
Page 260: ...GOT F900 SERIES CONNECTION Connection of MELSEC A Series PLC 9 9 30 MEMO ...
Page 290: ...GOT F900 SERIES CONNECTION Connection of MELSEC QnA Series PLC 10 10 30 MEMO ...
Page 322: ...GOT F900 SERIES CONNECTION Connection of MELSEC Q Series PLC 11 11 32 MEMO ...
Page 376: ...GOT F900 SERIES CONNECTION Connection of FREQROL S500 E500 A500 Inverter 13 13 38 MEMO ...
Page 412: ...GOT F900 SERIES CONNECTION Connection of Microcomputer 14 14 36 MEMO ...
Page 554: ...GOT F900 SERIES CONNECTION Connection of Printer 21 21 8 MEMO ...
Page 590: ...GOT F900 SERIES CONNECTION Appendix 23 23 24 MEMO ...
Page 591: ......