Technical Data

Mitsubishi Electric, MA00777A

3-1

3

Technical Data

Parameter

E1071

Front panel, W x H x D 219 x 154 x 6 mm 
Mounting depth

55 mm (155 mm including clearance) 

Front panel seal

IP 66

Rear panel seal

IP 20

Keyboard material/
Front panel

Touch screen: Polyester on glass *, 1 million finger touch 
operations. 
Overlay: Autotex F250 *.

Reverse side material

Powder-coated aluminum

Weight

1.1 kg 

Serial port RS422/
RS485

25-pin D-sub contact, chassis-mounted female with 
standard locking screws 4-40 UNC.

Serial port RS232C

9-pin D-sub contact, male with standard locking screws 4-40 
UNC.

Ethernet

Shielded RJ 45

USB

Host type A (USB 1.1), max output current 500mA
Device type B (USB 1.1)

CF-slot

Compact flash, type I and II

Flash memory for 
application

12 MB (incl. fonts)

Real time clock

±20 PPM + error because of ambient temperature and supply 
voltage. 
Total max error: 1 min/month at 25 

°

C

Minimum life of the real time clock battery: 3 years
Temperature coefficient: 0.004 ppm/

°

C

2

Power consumption at 
rated voltage

Normal: 0.4 A 
Maximum: 0.9 A

Display

TFT-LCD. 640 x 480 pixels, 64K color. 
CCFL backlight lifetime at the ambient temperature of 
+25 

°

C: >50,000 h.

Active area of display, 
W x H

131.5 x 98.6 mm 

Fuse

Internal DC fuse, 3.15 AT, 5 x 20 mm

Power supply

+24V DC (20 - 30V DC). 3-pin jack connection block.
CE: The power supply must conform with the requirements 
for SELV or PELV according to IEC 950 or IEC 742.
UL: The power supply must conform with the requirements 
for class II power supplies.

Ambient temperature

Vertical installation: 0 

° 

to +50 

°

C

Horizontal installation: 0 

° 

to +40 

°

C

Storage temperature

-20 

°

 to +70 

°

C

Relative humidity

5 - 85 % non-condensed

EMC tests on the 
operator terminal

The operator terminal conforms with the essential protection 
requirements in article 4 of the directive 89/336/EEC. Noise 
tested according to EN610

0

0-6-4 emission and EN61000-6-2 

immunity. 

UL, cUL approvals 
(when procuct or 
packing is marked)

UL 1604 Class I, Div 2 / UL 508 / UL 50 4x indoor use only

DNV

Yes

NEMA

4x indoor use only

* See section 

Chemical Resistance

Summary of Contents for E1071

Page 1: ...MITSUBISHI ELECTRIC E1071 Installation manual MA00777A 2006 04 English ...

Page 2: ...inting The manufacturer reserves the right to change any information without updating this publication The manufacturer assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only qualified personnel may install operate or repair this equipment The manufacturer is not responsible for modified altere...

Page 3: ...n 2 1 2 1 Space Requirements 2 1 2 2 Installation Process 2 1 2 2 1 Mode Switches 2 3 2 2 2 Connections to the Controller 2 3 2 2 3 Other Connections and Peripherals 2 3 3 Technical Data 3 1 4 Chemical Resistance 4 1 4 1 Metal Casing 4 1 4 2 Touch Screen and Overlay 4 1 4 2 1 Autotex F250 4 1 4 2 2 Touch Screen Surface 4 2 4 2 3 Autoflex EB 4 3 5 Operator Terminal Drawings 5 1 5 1 Communication Po...

Page 4: ...Table of Contents Mitsubishi Electric MA00777A ...

Page 5: ...ive 89 336 EEC Storing the operator terminal where the temperature is lower higher than recommended in this manual can cause the LCD display liquid to congeal become isotopic The LCD display liquid contains a powerful irritant In case of skin contact wash immediately with plenty of water In case of eye contact hold the eye open flush with plenty of water and get medical attention The supplier is n...

Page 6: ... supply Clean the display and surrounding front cover with a soft cloth and mild detergent Replacing the battery incorrectly may result in explosion Only use batteries recommended by the supplier 1 5 Dismantling and Scrapping The operator terminal or parts thereof shall be recycled according to local regulations The following components contain substances that might be hazardous to health and the ...

Page 7: ...npack and check the delivery If damage is found notify the supplier Note Place the operator terminal on a stable surface during installation Dropping it or letting it fall may cause damage 2 Place the panel cut out where the operator terminal is to be situated draw along the outer sides of the holes and cut according to the markings 50 mm 154 mm 219 mm 2 0 inch 50 mm 2 0 inch 100 mm 4 0 inch 100 m...

Page 8: ...4 0 5 1 0 Nm B C D A Caution Ensure that the operator terminal and the controller system have the same electrical grounding reference voltage level otherwise errors in communication may occur Caution Use only shielded communication cables Separate high voltage cables from signal and supply cables Caution The operator terminal must be brought to ambient temperature before it is started up If conden...

Page 9: ...erator terminal to the controller please refer to the help file for the driver in question 2 2 3 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable for the application and its environment For further details or recommendations please refer to the supplier Caution When using a compact flash card do not remove the card when the busy indicator is illuminate...

Page 10: ...Installation 2 4 Mitsubishi Electric MA00777A ...

Page 11: ...ck battery 3 years Temperature coefficient 0 004 ppm C2 Power consumption at rated voltage Normal 0 4 A Maximum 0 9 A Display TFT LCD 640 x 480 pixels 64K color CCFL backlight lifetime at the ambient temperature of 25 C 50 000 h Active area of display W x H 131 5 x 98 6 mm Fuse Internal DC fuse 3 15 AT 5 x 20 mm Power supply 24V DC 20 30V DC 3 pin jack connection block CE The power supply must con...

Page 12: ...Technical Data 3 2 Mitsubishi Electric MA00777A ...

Page 13: ...urated Lactic acid 10 Urea saturated FAM Normal petrol Sodium di chromate saturated Hydroperoxide 3 Alcohol 95 Caustic soda 5 Acetic acid 10 Phosphoric acid 43 Sodium hypochlorite solution Alu cleaner Glycol Sodium carbonate 10 Industrial petrol Sodium chloride 20 Potassium ferrocyanide ferricyanide Sodium hypchlorite 20 bleach 1 1 1 Trichloroethane Genklene Cyclohexanol Acetaldehyde Ethylacetate ...

Page 14: ...light 4 2 2 Touch Screen Surface The touch screen surface on the operator terminal withstands exposure to the following solvents without visible change Ammonia 40 Linseed oil Dioctyl Phthalate Caustic soda 40 Paraffin oil Sodium carbonate Hydrogen peroxide 25 Blown castor oil Petrol Alkalicarbonate Silicone oil Teepol Bichromate Turpentine substitute Water Diesel oil Univeral brake fluid Sea water...

Page 15: ...drocarbons Diethyl ether Glycol Toluene N Butyl acetate Isopropanol Xylene Amylacetate Glycerine White spirit Butycellosolve Methanol Fromic acid 50 Ether Triacetin Acetic acid 50 MIBK Dowanol DRM PM Phosphoric acid 30 Cutting oil Acetone Hydrochloric acid 36 Potassium carbonate Metyl ethyl ketone Nitric acid 10 Washing powders Dioxan Trichloracetic acid 50 Fabric conditioner Cyclohexanone Sulphur...

Page 16: ...under critical viewing conditions with the following materials Outdoor Use In common with all polyester based films Autoflex EB is not suitable for use in conditions of long term exposure to direct sunlight Top Job Grape Juice Ariel Ajax Jet Dry Milk Persil Vim Gumption Coffee Wisk Domestos Fantastic Lenor Vortex Formula 409 Downey Windex Tomato juice Tomato ketchup Lemon juice Mustard ...

Page 17: ...Operator Terminal Drawings Mitsubishi Electric MA00777 5 1 5 Operator Terminal Drawings 5 1 Communication Ports Drawing No S 5005 Date 2004 10 27 RS 232 RS 422 RS 422 485 RS 485 Ethernet USB ...

Page 18: ...Operator Terminal Drawings 5 2 Mitsubishi Electric MA00777 5 2 E1071 Outline Drawing No S 5055 Date 2004 10 26 ...

Page 19: ......

Page 20: ...Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Mitsubishi Electric Europe B V Gothaer Strasse 8 D 40880 Ratingen Germany MITSUBISHI ELECTRIC ...

Reviews: