E1032

Installation Manual

English

MA00816D, 2014-12

Summary of Contents for E1032

Page 1: ...E1032 Installation Manual English MA00816D 2014 12 ...

Page 2: ...shi Electric Automation Inc assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only qualified personnel may install operate or repair this equipment Mitsubishi Electric Automation Inc is not responsible for modified altered or renovated equipment Because the equipmenthas a wide range of applicatio...

Page 3: ...echnicalData 11 4 ChemicalResistance 12 4 1 MetalCasing 12 4 2 Screen and Overlay Material 12 4 2 1 Autotex F157 207 12 4 2 2 Screen Surface 13 4 2 3 Screen and Keyboard Protector 14 5 Operator Panel Drawings 15 5 1 Communication Ports 15 5 2 E1032 Outline 16 5 3 E1032 Text Strip 17 6 Additional Installation Tips 18 6 1 Grounding the Operator Panel 18 6 2 Ethernet Connection in the Panel 19 6 3 To...

Page 4: ...insa powerful irritant Incase of skincontact wash immediately with plenty ofwater In case of eye contact holdthe eye open flush with plenty of water and get medical attention The figures in this manualserves an illustrative purpose Because of the many variables associated with any particular installation the supplier cannot assume responsibility for actual use based onthe figures The supplierneither ...

Page 5: ...REUSE This product contains a battery this must onlybe changedin an areaknown tobe non hazardous Replace the battery with aCR2450 battery Use of anothertype ofbattery maypresent a risk offire orexplosion Warning Battery may explode if mistreated Do not recharge disassemble or dispose of in fire LA BATTERIEPEUT EXPLOSEREN CAS DE MAUVAISE MANIPULATION NE LA RECHARGEZ PAS NE LA DÉMONTEZ PAS ET NE LA J...

Page 6: ...the poweroutlet Peripheral equipment must be appropriate forthe application and location 1 4 During Use Keep the operatorpanel clean Emergency stopand othersafety functions may notbe controlled from the operator panel Do not use excessive force orsharpobjects on the displayorthe keys 1 5 Service and Maintenance Onlyqualified personnel shouldcarry outrepairs The agreed warranty applies Before carryi...

Page 7: ...ch 7 36 inch 202 mm 100 mm 4 0 inch 7 95 inch 2 24 inch Caution The openings on the enclosure are for airconvection Do not cover these openings 2 2 Installation Process 1 Unpackand check the delivery If damage isfound notify the supplier x 7 Panel cut out 166 x 149 mm 6 54 x 5 87 inch Note Place the operator panelon a stable surface duringinstallation Dropping it or letting itfall may cause damage...

Page 8: ...uated draw along the outer sides ofthe holesandcutaccording to the markings For text strip 7 0 mm 14 0 mm 0 55 inch 0 28 inch 3 Secure the operator panel in position usingallthe fasteningholesand the provided brackets and screws x 7 0 5 1 0 Nm Mitsubishi Electric MA00816D 8 ...

Page 9: ...ise errors in communication may occur Ensure that the voltage and polarity of the powersource is correct Separate high voltage cables from signal and supply cables Shielded communication cables are recommended 24V DC RS422 RS485 RS232 24V DC A D Controller Power C B Ethernet Connect cable A Connect cable B usingan M5 screwand agroundingconductor asshort as possible thatissized correctly accordingt...

Page 10: ...ections to the Controller For information aboutthe cables to be used when connecting the operator panelto the controller please refer to the helpfile for the driverin question 2 2 3 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable forthe application and itsenvironment Forfurtherdetailsor recommendations please refertothe supplier Mitsubishi Electric MA0...

Page 11: ...ute month at 25 C Temperature coefficient 0 034 0 006 ppm C2 Real time clock battery CR2450 UL and cUL Sanyo or Panasonic Minimum lifetime 3 years Power consumption at rated voltage Normal 0 15 A Maximum 0 35 A Display FSTN LCD 240 x64 pixels monochrome transflective LED backlight lifetime at the ambient temperature of 25 C 35 000 h Active area of display W xH 127 0 x 33 8 mm Fuse Internal DC fuse...

Page 12: ...chloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Turpentine Note If exposure to any of the above chemicals is demanded itis recommended to first test the chemical in a hidden spot of the metal casing The powder paint shows little or no resistance to the followingchemicals at room temperature Acetic acid conc Methyl ethyl ketone Toluene Acetone Nitric acid 30 Tr...

Page 13: ...ffin oil Windex1 Cyclohexanol Persil powderin solution1 Wisk Diacetone alcohol Petroleum spirit1 1 Extremely faintglossingof the texture was noted Autotex withstands DIN 42 115 Part2 exposure of up to 1 hour duration to glacial aceticacid without visible change Autotex is not resistant to high pressure steam at over 100 C orthe following chemicals Concentrated mineral acids Benzylalcohol Concentra...

Page 14: ... Protector For harsh environments and exposure tooutdoorconditions it isrecommended to use a protective film toguardthe screen and the keyboard from damage These optional parts canbe ordered from Mitsubishi Electric Mitsubishi Electric MA00816D 14 ...

Page 15: ...Operator PanelDrawings 5 Operator Panel Drawings 5 1 Communication Ports RS 232 RS 422 RS 422 485 RS 485 Ethernet USB Mitsubishi Electric MA00816D 15 ...

Page 16: ...Operator PanelDrawings 5 2 E1032 Outline Mitsubishi Electric MA00816D 16 ...

Page 17: ...Operator PanelDrawings 5 3 E1032 Text Strip 4 5 19 75 20 5 20 5 20 5 20 5 20 5 19 75 179 Text max 18 5x8 0 Text max 17 0x8 0 10 75 9 Mitsubishi Electric MA00816D 17 ...

Page 18: ...aid between the panel s chassis and the closest groundingpoint on the door see 3 in drawingabove 3 Connect astrongbut shortgroundingbraid betweenthe doorand the device cabinet see 4 indrawingabove 4 Twist the cables onto the 24 V DC feed see 5 in drawingabove 2 turns around the ferrite core provide 4 times the suppressionof1 turn 3 turns around the ferrite core provide 9 times the suppressionof1 t...

Page 19: ...nithas its shield directly grounded or groundedviaa capacitor Note In many cases connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate Hum or grounding loops canoccur Unshielded cabling may even result in fewer communication errors A good solutionmay be touse a shielded Ethernet cable but toconnect the shield at one end only One option istobreak the shield see 3 in ...

Page 20: ...he shield to the groundviaa 0 1 μ F 250 Vplastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms ofLF thus avoidingthe 50 Hz groundingloops Metal cabinet Metal cabinet Terminal or connector Terminal or connector EMC cable gland Plastic cable gland Shielded cable Shielded cable Short distance Cable clamp in steel 5353 1 Use an E...

Page 21: ... a large program for controllingthe temperature in the device cabinet An enamel coated steel cabinethasaradiant heatvalue of 5 5 W m2 and degrees C Installinga fan inside the cabinetwill even out the temperature while moving air providesconsiderably better coolingthan stillair Asuitable fan is a120 x120 mm axialfan available in 24 VDC 115 and 230 V AC Install the fan so that it sitsin the cooler a...

Page 22: ...LVaccording to EN 60950 protection against electric shock andUL 950 Note Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay contacts in a smaller controller Check that the clearances and creepage distances between 24 V DC and 230 V AC fulfill EN 60950 or UL 950 If not input a separate 24 V unit into the operator panel If there...

Page 23: ...SB memory stick keyboard or similardevice is plugged in If anumberofunitsare connectedthat have a0 Vand a groundconnection and these are connected to various groundingpoints there is a substantial risk of problems Groundingcurrents go through communication cables the rearplate of the controller andinternally in the operatorpanel and can cause errors Use external units to improve communication and ...

Page 24: ...ires may be onthe same levelor require pull up orpull downtoensure that no faultysignals are detected when the busisin restingmode all transmittersare disconnected 1 2 3 4 5 V 0 V 1 K 1 K 120 ohm 120 ohm 120 ohm 5 V 5 V 0 V 0 V 0 V 0 V 0 V 0 V 1 K 1 K 1 K 1 K VCC VCC 120 ohm Inside operator panel Operator panel RS422 CAB8 CAB8 Bus RS485 Shield Bus termination 5358 2 14 15 6 19 7 8 1 2 3 4 5 6 7 8 ...

Page 25: ...Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Mitsubishi Electric Europe B V Gothaer Strasse 8 D 40880 Ratingen Germany ...