MEES21K047
PQ
R
Y-
P-
Z(
S)
LM
U
-A
1
98
11. M-NET CONTROL
WR2-Series-575V
11. M-NET CONTROL
11-1. Transmission cable length limitation
V+V-FG
n
V+V-FG
V+V-FG
n
V+V-FG
AE-200A
L
4
S
A B
AE-200A
L
6
S
A B
Long transmission cable causes voltage down, therefore, the length limitation should be obeyed to secure proper transmission.
OC, OS: Heat source unit controller; IC: Indoor unit controller; ME: ME remote controller
OC, OS: Heat source unit controller; IC: Indoor unit controller; ME: ME remote controller
M2
TB7
TB3
IC
(52)
M1
M2
1 2
S
TB5
TB15
1 2
TB15
1 2
TB15
1 2
TB15
1 2
TB15
1 2
TB 15
1 2
TB15
MA
(01)
IC
M1
M2 S
TB5
(02)
IC
M1
M2 S
TB5
(04)
IC
M1
M2 S
TB5
(03)
IC
M1
M2 S
TB5
(05)
IC
M1
M2 S
TB5
(07)
IC
M1
M2 S
TB5
(06)
L
2
L
1
L
6
MA
MA
OS
TB7
(51)
OC
M1 M2 S
TB7
TB3
(54 )
OC
a1
a3
L
8
L
3
A B
A B
A B
BC(Sub)
M1
M2 S
TB02
(55)
BC(Sub)
M1
M2 S
TB02
(57)
a1
a1
MA
A B
a4
a2
Group1
Group3
Group5
S
Power Supply Unit
AG-150A-A
PAC-SC51KUA
L
4
L
2
L
5
A B
S
A B
M2
M1
M1
M2
M1
M2 S
M2
M1
M1
S
TB3
IC
Group1
Group3
Group5
M1
M2 S
TB5
ME
(01)
IC
M1
M2 S
TB5
(02)
IC
M1
M2 S
TB5
(04)
IC
M1
M2 S
TB5
(03)
IC
M1
M2 S
TB5
(05)
IC
M1
M2 S
TB5
(07)
IC
M1
M2 S
TB5
(06)
L
1
(101)
ME
(105)
ME
(103)
ME
(155)
L
4
L
5
e2
e1
e3
e4
A B
A B
A B
A B
a2
a2
S
A B
S
A B
Shielded wire
M2
BC(Main)
M1
M2 S
TB02
(53)
BC(Main)
M1
S
TB02
(56)
Shielded wire
M2
BC(Main)
M1
M2 S
TB02
(53)
BC(Main)
M1
S
TB02
(56)
BC(Sub)
M1
M2 S
TB02
(55)
BC(Sub)
M1
M2 S
TB02
(57)
M2
TB7
TB3
(52)
OS
TB7
(51)
OC
M1 M2 S
TB7
TB3
(54 )
OC
L
3
Power Supply Uni
t
AG-150A-A
PAC-SC51KUA
L
6
L
7
M2
M1
M1
M2
M1
M2 S
M2
M1
M1
S
TB3
11-1-2. Using ME Remote controller
11-1-1. Using MA Remote controller
MA remote controller refers to Simple MA remote controller and wireless remote controller.
Max. length via Heat source (M-NET cable) L1+L2+L3, L1+L2+L4+L5, L3+L4+L5, L6+L2+L3, L6+L2+L4+L5 <=500m[1640ft.]
1.25mm
2
[AWG16] or thicker
Max. length to Heat source (M-NET cable) L1+L6, L3, L2+L4+L6, L5
<=200m[656ft.]
1.25mm
2
[AWG16] or thicker
Max. length from MA to Indoor for each group a1+a2, a1+a2+a3+a4
<=200m[656ft.]
0.3-1.25 mm
2
[AWG22-16]
24VDC to AG-150A-A
n
<=50m[164ft.]
0.75-2.0 mm
2
[AWG18-14]
ME remote controller refers to Smart ME Controller.
Long transmission cable causes voltage down, therefore, the length limitation should be obeyed to secure proper transmission.
*1. If the length from ME to Indoor exceed 10m, use 1.25 mm
2
[AWG16] shielded cable, but the total length should be counted into Max. length via Heat source.
Max. length via Heat source (M-NET cable) L1+L2+L3+L4, L1+L2+L6+L7, L1+L2+L3+L5, L3+L4+L6+L7, L8+L2+L3+L4,
L8+L2+L3+L5, L8+L2+L6+L7, L3+L5+L6+L7
Max. length to Heat source (M-NET cable) L1+L8, L3+L4, L2+L6+L8, L7, L3+L5
Max. length from ME to Indoor
e1, e2, e3, e4
24VDC to AG-150A-A
n
<=500m[1640ft.] 1.25mm
2
[AWG16] or thicker
<=200m[656ft.]
1.25mm
2
[AWG16] or thicker
<=10m[32ft.]*1
0.3-1.25 mm
2
[AWG22-16]*1
<=50m[164ft.]
0.75-2.0 mm
2
[AWG18-14]
0000006382.BOOK 98 ページ 2021年7月19日 月曜日 午後4時14分