background image

Air-Conditioners For Building Application
INDOOR UNIT

PFFY-P-VLRMM-E

GB

D

F

E

I

NL

P

SV

INSTALLATIONSHANDBUCH

Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.

MANUEL D’INSTALLATION

Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte.

MANUAL DE INSTALACIÓN

Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d’aria.

INSTALLATIEHANDLEIDING

Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.

MANUAL DE INSTALAÇÃO

Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.

GR

RU

TR

HG

PO

CZ

ΕΓΧΕΙΡΙΔΙΟ

 

ΟΔΗΓΙΩΝ

 

ΕΓΚΑΤΑΣΤΑΣΗΣ

Για

 

ασφάλεια

 

και

 

σωστή

 

χρήση

παρακαλείστε

 

διαβάσετε

 

προσεχτικά

 

αυτό

 

το

 

εγχειρίδιο

 

εγκατάστασης

 

πριν

 

αρχίσετε

 

την

 

εγκατάσταση

 

της

 

μονάδας

 

κλιματισμού

.

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

Для

 

осторожного

 

и

 

правильного

 

использования

 

прибора

 

необходимо

 

тщательно

 

ознакомиться

 

с

 

данным

 

руководством

 

по

 

установке

 

до

 

выполнения

 

установки

 

кондиционера

.

MONTAJ ELK

İ

TABI

Emniyetli ve do

ğ

ru biçimde nasıl kullanılaca

ğ

ını ö

ğ

renmek için lütfen klima cihazını monte etmeden önce bu elkitabını dikkatle okuyunuz.

P

Ř

ÍRU

Č

KA K INSTALACI

V zájmu bezpe

č

ného a správného používání si p

ř

ed instalací klimatiza

č

ní jednotky d

ů

kladn

ě

 pro

č

t

ě

te tuto p

ř

íru

č

ku k instalaci.

NÁVOD NA INŠTALÁCIU

Pre bezpe

č

né a správne použitie si pred inštalovaním klimatiza

č

nej jednotky, prosím, starostlivo pre

č

ítajte tento návod na inštaláciu.

TELEPÍTÉSI KÉZIKÖNYV

A biztonságos és helyes használathoz, kérjük, olvassa el alaposan ezt a telepítési kézikönyvet, miel

ő

tt telepítené a légkondicionáló egységet.

PODR

Ę

CZNIK INSTALACJI

W celu bezpiecznego i poprawnego korzystania nale

ż

y przed zainstalowaniem klimatyzatora dok

ł

adnie zapozna

ć

 si

ę

 z niniejszym podr

ę

cznikiem instalacji.

SL

SW

HR

BG

RO

PRIRO

Č

NIK ZA NAMESTITEV

Za varno in pravilno uporabo pred namestitvijo naprave enote skrbno preberite ta priro

č

nik za namestitev.

INSTALLATIONSHANDBOK

Läs den här installationshandboken noga innan luftkonditioneringsenheten installeras, för säker och korrekt användning.

PRIRU

Č

NIK ZA UGRADNJU

Radi sigurne i ispravne uporabe, temeljito pro

č

itajte ovaj priru

č

nik prije ugradnje unutarnje jedinice.

РЪКОВОДСТВО

 

ЗА

 

МОНТАЖ

За

 

безопасна

 

и

 

правилна

 

употреба

моля

прочетете

 

внимателно

 

това

 

ръководство

 

преди

 

монтажа

 

на

 

климатизатора

.

MANUAL CU INSTRUC

Ţ

IUNI DE INSTALARE

Pentru o utilizare corect

ă

 

ş

i sigur

ă

, v

ă

 rug

ă

m citi

ţ

i cu aten

ţ

ie acest manual înainte de a instala unitatea intern

ă

.

Summary of Contents for City Multi PFFY-P-VLRMM-E

Page 1: ...ния прибора необходимо тщательно ознакомиться с данным руководством по установке до выполнения установки кондиционера MONTAJ ELKİTABI Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını monte etmeden önce bu elkitabını dikkatle okuyunuz PŘÍRUČKA K INSTALACI V zájmu bezpečného a správného používání si před instalací klimatizační jednotky důkladně pročtěte tuto příru...

Page 2: ... D Electrical part service space A Floor hole for fixing Fig 4 1 2 220 F 205 E 114 630 F 205 E 170 300 For fixing on the floor Viewed from bottom of the unit For fixing on the wall Viewed from front of the unit Model name E F 20 25 1050 640 32 40 1170 760 50 63 1410 1000 Fig 4 1 3 PFFY VLRMM E X W Z L A 4 2 A B C A Floor hole for fixing B Level adjusting screws supplied C Screw plate supplied Fig ...

Page 3: ...ter ø 27 end ø 20 F Air filter G Electrical part box Fig 5 1 1 6 2 Fig 6 2 1 A Cut here B Remove brazed cap A Thermal insulation B Pull out insulation C Wrap with damp cloth D Return to original position E Ensure that there is no gap here F Wrap with insulating tape Fig 6 1 1 Fig 6 1 3 A Cool by a wet cloth 6 6 1 A A E C F B D Fig 6 1 2 7 7 1 Fig 7 1 1 A B C D E F G A A Ground fault interrupter B ...

Page 4: ...or indoor unit and BC controller Fig 7 3 3 A Terminal block B Round terminal C Shield wire D The earth wire from two cables are connected to gether to the S terminal Dead end connection E Insulation tape To keep the earth wire of the shielded cable from coming in contact with the transmission terminal Fig 7 3 4 M2 S M1 A B C E D Address board Fig 7 4 1 7 4 A Non polarized B TB15 C Remote Controlle...

Page 5: ... other than R410A If another refrigerant R22 etc is used the chlorine in the refrigerant may cause the refrigerator oil to deteriorate 1 Safety precautions 5 1 1 Before installation and electric work 5 1 2 Precautions for devices that use R410A refrigerant 5 1 3 Before getting installed 6 1 4 Before getting installed moved electrical work 6 1 5 Before starting the test run 6 2 Indoor unit accessor...

Page 6: ...to this Installation Manual to ensure proper drainage Wrap thermal insulation around the pipes to prevent condensation Improper drain piping may cause water leakage and damage to furniture and other possessions Be very careful about product transportation Only one person should not carry the product if it weighs more than 20 kg Some products use PP bands for packaging Do not use any PP bands for a...

Page 7: ...ved from the unit Model name PFFY P20VLRMM E PFFY P25VLRMM E PFFY P32VLRMM E PFFY P40VLRMM E PFFY P50VLRMM E PFFY P63VLRMM E W 640 640 760 760 1000 1000 L 100 100 100 100 100 100 X 17 17 17 17 17 17 Z 335 335 335 335 335 335 Product Weight kg 18 5 18 5 20 21 25 27 5 Refrigerant pipe and drain pipe specifications To avoid dew drops provide sufficient antisweating and insulating work to the re frige...

Page 8: ...ngth and allowable difference of elevation refer to the outdoor unit manual The method of pipe connection is brazing connection Caution Install the refrigerant piping for the indoor unit in accordance with the following 1 Cut the tip of the indoor unit piping remove the gas and then remove the brazed cap Fig 6 1 1 P 3 A Cut here B Remove brazed cap 2 Pull out the thermal insulation on the site ref...

Page 9: ...cables MA Remote controller cables Sheathed 2 core cable unshielded CVV Cable diameter More than 1 25 mm2 0 3 1 25 mm2 0 75 1 25 mm2 1 0 3 1 25 mm2 0 75 1 25 mm2 1 Max length 200 m Maximum length of transmission lines for centralized control and indoor outdoor transmission lines Maximum length via indoor units 500 m MAX The maximum length of the wiring between power supply unit for transmission li...

Page 10: ...terminal block box in the reverse order of removal Notes Do not pinch the cables or wires when attaching the terminal block box cover Doing so may cause a risk of disconnection When accommodating the terminal block box make sure that the con nectors on the box side are not removed If removed it cannot operate normally Caution Fix the electrical wires at site using clamps Caution Wire the power sup...

Page 11: ...ive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Machinery Directive 2006 42 EC Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Authorized representative in EU MITSUBISHI ELECTRIC EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDGE MIDDLESEX UB8 1QQ U K...

Reviews: