III
Specifications ]
- 6 -
HWE18200
GB
*1 <Cooling> Indoor temperature: 27°CDB/19°CWB (81°FDB/66°FWB) Outdoor temperature: 35°CDB (95°FDB)
<Heating> Indoor temperature: 20°CDB (68°FWB) Outdoor temperature: 7°CDB/6°CWB (45°FDB/43°FWB)
*2 Figures in the parentheses indicate drainpump-less Model (L).
Model
PEFY-
W50VMA(L)-
A
PEFY-
W63VMA(L)-
A
PEFY-
W71VMA(L)-
A
PEFY-
W80VMA(L)-
A
Power supply
Voltage
V
1-phase 220-230-240
Frequency
Hz
50
Cooling capacity
*1
kW
5.6
7.1
8.0
9.0
Heating capacity
*1
kW
6.3
8.0
9.0
10.0
Power consumption
*2
Cooling
kW
0.093(0.091)
Heating
kW
0.091
Current consumption
Cooling
A
0.68
Heating
A
0.68
External finish
Galvanized
Dimensions
Height
mm
250
Width
mm
1100
Depth
mm
732
Net weight
*2
kg
30(29)
Heat exchanger
Cross fin(Aluminium fin and copper tube)
Fan
Type
Sirocco fan x 2
Airflow rate
(Low-Mid-High)
m
3
/min
14.5-18.0-21.0
External static
pressure
Pa
40/50/70/100/150
Motor
Output
kW
0.121
Air filter
PP Honeycomb fabric (washable)
Water pipe
dimensions
Gas (Inlet
connection)
mm I.D.
20
30
Liquid (Outlet
connection)
mm I.D.
20
30
Drain pipe dimensions
mm[in.]
O.D. 32[1-1/4]
Operating noise(Low-Mid-High)
35Pa / 40Pa
dB (A)
23-28-32
50Pa
26-29-33
70Pa
26-31-35
100Pa
27-33-37
150Pa
30-36-40
35Pa / 40Pa
26-31-35
50Pa
29-32-36
70Pa
29-34-38
100Pa
30-36-40
150Pa
33-39-43
Measurement location 1
Aux. duct
*
Measured in anechoic room.
2m
2m
1.
5m
*
Measured in anechoic room.
2m
1m
Aux. duct
1.
5m
Measurement location 2
HWE18200.book 6 ページ 2019年5月8日 水曜日 午前10時52分