7. Installation, transferring works, and checking

Regarding place for installation

Consult with your dealer for details on installation and transferring the installation.

 Caution:

Never install the air conditioner where there is a risk of leakage of flammable
gas.
If gas leaks and accumulates around the unit, fire can result.

Never install the air conditioner at the following place:

where there is a lot of machine oil

near the ocean and beach areas where there is salt air.

where humidity is high

where there are hot springs nearby

where there is sulphurous gas

where there is a high-frequency processing machinery (a high-frequency welder,
etc.)

where acid solution is frequently used

where special sprays are frequently used

Install the indoor unit horizontally. Otherwise, water leakage can result.

Take sufficient measures against noise when installing the air conditioners at
hospitals or communication-related businesses.

If the air conditioner is used in any of the above-mentioned environments, frequent
operational failure can be expected. It is advisable to avoid these types of installa-
tion sites.
For further details, consult with your dealer.

Regarding electrical work

 Caution:

The electrical work must be undertaken by a person who is qualified as
an electrical engineer according to the [technical standard respecting
electrical installation], [internal wiring rules], and the installation instruc-
tion manual with the absolute use of exclusive circuits. The use of other
products with the power source can result in burnt-out beakers and fuses.

Never connect the grounding wire to a gas pipe, water pipe, arrester, or
telephone grounding wire. For details, consult with your dealer.

In some types of installation sites, the installation of an earth leakage
breaker is mandatory. For details, consult with your dealer.

Regarding transfer of installation

When removing and reinstalling the air conditioner when you enlarge your
home, remodel, or move, consult with your dealer in advance to ascertain the
cost of the professional engineering work required for transferring the installa-
tion.

 Caution:

When moving or reinstalling the air conditioner, consult with your dealer.
Defective installation can result in electric shock, fire, etc.

Regarding noise

In installing work, choose a place that can fully bear the weight of the air con-
ditioner, and where noise and vibration can be reduced.

Choose a place where cool or warm air and noise from the outdoor air outlet of
the air conditioner does not inconvenience the neighbors.

If any alien object is placed near the outdoor air outlet of the air conditioner,
decreased performance and increased noise can result. Avoid placing any
obstacles adjacent to the air outlet.

If the air conditioner produces any abnormal sound, consult with your dealer.

Maintenance and inspection

If the air conditioner is used throughout several seasons, the insides can get
dirty, reducing the performance.

Depending upon the conditions of usage, foul odors can be generated and
drainage can deteriorate due to dust and dirt, etc.

8. Specifications

Notes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.

Cooling: Indoor: 27 

°

C DB/19 

°

C WB

Outdoor: 35 

°

C DB

Heating: Indoor: 20 

°

C DB

Outdoor: 7 

°

C DB/6 

°

C WB

*2 The figure in (  ) indicates panel’s.
*3 The operating noise is the data that was obtained in an anechoic room.

Power source
Cooling capacity*1 / Heating capacity*1

kW

Height

mm

Dimension*2

Width

mm

Depth

mm

Net weight

kg

Fan Airflow rate (Low-Middle-High)

m

3

/min

Noise level

220V, 240V

(Low-Middle-High)*3

dB(A)

230V

Filter

P32VLMD-E

3.6/4.0

290 (20)

776 (1,080)

634 (710)

24 (6.5)

6.5-8.0-9.5

27-30-33
28-31-34

P20VLMD-E

2.2/2.5

290 (20)

776 (1,080)

634 (710)

23 (6.5)

6.5-8.0-9.5

27-30-33
28-31-34

P50VLMD-E

5.6/6.3

290 (20)

946 (1,250)

634 (710)

27 (7.5)

9.0-11.0-12.5

31-34-37
32-35-38

Item

Model

P25VLMD-E

2.8/3.2

290 (20)

776 (1,080)

634 (710)

23 (6.5)

6.5-8.0-9.5

27-30-33
28-31-34

P40VLMD-E

4.5/5.0

290 (20)

776 (1,080)

634 (710)

24 (6.5)

7.0-8.5-10.5

29-33-36
30-34-37

~220-240V 50Hz/~220-230V 60Hz

PLFY-P-VLMD-E series

Long life filter

P63VLMD-E

7.1/8.0

290 (20)

946 (1,250)

634 (710)

28 (7.5)

10.0-13.0-15.5

33-38-40
34-39-41

Power source
Cooling capacity*1 / Heating capacity*1

kW

Height

mm

Dimension*2

Width

mm

Depth

mm

Net weight

kg

Fan Airflow rate (Low-Middle-High)

m

3

/min

Noise level

220V, 240V

(Low-Middle-High)*3

dB(A)

230V

Filter

P125VLMD-E

14.0/16.0

290 (20)

1,708 (2,010)

606 (710)

56 (13)

24.0-27.0-30.0-33.0

(Low-Middle2-Middle1-High)

40-42-44-46

P80VLMD-E

9.0/10.0

290 (20)

1,446 (1,750)

634 (710)

44 (12.5)

15.5-18.5-22.0

33-36-39
34-37-40

Item

Model

P100VLMD-E

11.2/12.5

290 (20)

1,446 (1,750)

634 (710)

47 (12.5)

17.5-21.0-25.0

36-39-42
37-41-43

~220-240V 50Hz/~220-230V 60Hz

Long life filter

Summary of Contents for City Multi PDFY-P-VM-E

Page 1: ...cto ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa BEDIENINGSHANDLEIDING Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt MANUAL DE OPERAÇÃO Para segurança e utilização correctas leia atentamente o manual de operação antes ...

Page 2: ...te Ventilazione 9 Pulsante Controllo Incorporata 0 Pulsante Prova di funzionamento A Pulsante Filtro B Pulsante ACCENSIONE SPEGNIMENTO C Posizione temperatura ambiente incorporata Non esporre mai il comando a distanza alla luce diretta del sole in quanto questo può alterare la corretta rilevazione della temperatura ambiente Non porre alcun ostacolo attorno alla sezione inferiore destra del comando...

Page 3: ... Dü mesi 6 Vantilatör H z Ayarlama Dü mesi 7 Hava Ak m n Afla Yukar Yönlendirme Dü mesi 8 Havaland rma Dü me 9 Kontrol Entegre Dü me 0 Deneme Çal flt rmas Dü me A Filtre Dü mesi B Açma Kapama Dü mesi C Entegre oda s cakl konumu Uzaktan kumanda ünitesini günefl fl na maruz b rakmay n Aksi taktirde oda s cakl n n yanl fl ölçülmesine neden olabilirsiniz Uzaktan kumanda ünitesinin sa alt köflesinin önünü hi...

Page 4: ...tion non disponible L Ventilation M Mode de réglage du fonctionnement N Mode d essai de fonctionnement O Mode de vérification des erreurs P Signe du filtre Q Réglage après une heure R Position du capteur S Température de la pièce T Flux d air U Vitesse du ventilateur A Ora corrente Timer B Comando centralizzato C Timer attivato D Si verifica un anomalia E Modo funzionamento COOL DRY AUTO FAN HEAT ...

Page 5: ... Programlama modu SO UTMA KURUTMA OTOMAT K FAN ISITMA F Is tma moduna haz rl k G Buz giderme modu H stenilen S cakl k I Elektrik AÇIK J Pancur K Kullan lamayan fonksiyon L Havaland rma M Fonksiyon ayarlama modu N Deneme çal flt rmas modu O Hata kontrol modu P Filtre iflareti Q Bir Saat Boyunca Etkin K lma R Sensör konumu S Oda s cakl T Hava Ak m U Vantilatör H z A Ú Ô Û ÒÚ ÃÚÔÓÔ È Îfi ÙË B ÂÓÙÚÈÎÔ ÂÏ...

Page 6: ...ée arrière En el caso de unidad interior trasera In caso di ingresso dell aria dalla parte posteriore Bij een achterinlaat No caso de unidade interior traseira  ÂÚ ÙˆÛË Ûˆ ÂÈÛ ÁˆÁ При воздухозаборнике сзади Arka girifl durumunda 2 In case of bottom inlet Bei Einlass von unten En cas d entrée sur le dessous En el caso de unidad interior inferior In caso di ingresso dell aria dalla parte inferiore B...

Page 7: ... and noise emit ted by the unit will not disturb the neighbours 2 Indoor unit Warning The indoor unit should be securely installed If the unit is loosely mounted it may fall causing injury 3 Remote controller Warning The remote controller should be installed in such a way that children cannot play with it 4 Drain hose Caution Make sure that the drain hose is installed so that drainage can go ahead...

Page 8: ...t of filter Fig A P 6 TIMER SET PAR 20MAA ON OFF CENTRALLY CONTROLLED ERROR CODE CLOCK ON OFF C CHECK CHECK MODE FILTER TEST RUN FUNCTION C 1Hr NOT AVAILABLE STAND BY DEFROST FILTER CHECK TEST TEMP 3 2 E C A 1 6 8 7 4 B 3 How to operate Before starting operation Start running after the H0 display has disappeared The H0 display briefly appears on the room temperature display max 3 minutes when the ...

Page 9: ...D BY Displayed from the start of heating operation until the moment warm air blows out Caution When the air conditioner is used together with burners thoroughly ven tilate the area Insufficient ventilation can result in accidents due to oxy gen deficiency Never place a burner at a place where it is exposed to the airflow from the air conditioner Doing so can result in imperfect combustion of the b...

Page 10: ...failure can result It is particularly important to clean the filter at the beginning of the cooling and heating sea sons When profuse dust and dirt have accumulated clean the filter thoroughly ON OFF ON OFF Display example of timer setting The example shows a timer set for operation start at 8 00 and end at 17 00 1 Press the 2 2 2 2 2 timer continuous button and bring up the C C C C C no display 2...

Page 11: ...led with dust and dirt There are some obstacles at the air inlet and outlet of the indoor and outdoor units Windows and doors are open The restart preventing circuit is in operation for 3 min utes Indoor unit operation was restarted during the heating and defrosting operation There are some obstacles at the air inlet and outlet of the indoor and outdoor units The filter is filled with dust and dir...

Page 12: ... etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool or warm air and noise from the outdoor air outlet of the air conditioner does not inconvenience the neighbors If any alien object is placed near the outdoor air outlet of the air conditioner decreased performance and in...

Page 13: ...ic pressure 2 Pa Noise level Low Middle High 5 dB A Filter Item Model P25VMM E 2 8 3 2 295 815 700 27 6 0 7 2 8 5 30 50 100 27 30 32 P40VMM E 4 5 5 0 295 935 700 33 10 0 12 0 14 0 30 50 100 31 34 37 PEFY P VMM E series P80VMM E 9 0 10 0 295 1 175 700 42 14 5 18 0 21 0 30 50 100 32 36 39 P63VMM E 7 1 8 0 295 1 175 700 42 13 5 16 2 19 0 30 50 100 31 35 38 Power source Cooling capacity 1 Heating capa...

Page 14: ...20 C DB Outdoor 7 C DB 6 C WB 2 The figure in indicates panel s 3 The external static pressure is set to 50 Pa at factory shipment 4 The figure in indicates noise level at 240 V 50 Hz Operation temperature Cooling mode 15 C WB 24 C WB Heatingmode 15 C DB 27 C DB 5 The figures represent a 240 V 50 Hz unit measured at a point which is 1 m away from the front of the unit and at a height of 1 m from t...

Page 15: ...e contact address telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Page 16: ......

Reviews: