background image

9

GB

D

F

E

I

NL

P

GR

RU

TR

TR

7. Installation, transferring works, and checking

Regarding place for installation

Consult with your dealer for details on installation and transferring the installation.

 Caution:

Never install the air-conditioner where there is a risk of leakage of flamma-
ble gas. 
If gas leaks and accumulates around the unit, fire can result.

Never install the air-conditioner at the following place:

where there is a lot of machine oil

near the ocean and beach areas where there is salt air.

where humidity is high

where there are hot springs nearby

where there is sulphurous gas

where there is a high-frequency processing machinery (a high-frequency
welder, etc.)

where acid solution is frequently used

where special sprays are frequently used

Install the indoor unit horizontally. Otherwise, water leakage can result.

Take sufficient measures against noise when installing the air-conditioners at
hospitals or communication-related businesses.

If the air-conditioner is used in any of the above-mentioned environments, fre-
quent operational failure can be expected. It is advisable to avoid these types of
installation sites.
For further details, consult with your dealer.

Regarding electrical work

 Caution:

• The electrical work must be undertaken by a person who is qualified as

an electrical engineer according to the [technical standard respecting
electrical installation], [internal wiring rules], and the installation instruc-
tion manual with the absolute use of exclusive circuits. The use of other
products with the power source can result in burnt-out beakers and
fuses.

• Never connect the grounding wire to a gas pipe, water pipe, arrester, or

telephone grounding wire. For details, consult with your dealer.

• In some types of installation sites, the installation of an earth leakage

breaker is mandatory. For details, consult with your dealer.

Regarding transfer of installation

When removing and reinstalling the air-conditioner when you enlarge your
home, remodel, or move, consult with your dealer in advance to ascertain the
cost of the professional engineering work required for transferring the instal-
lation.

 Caution:

When moving or reinstalling the air-conditioner, consult with your dealer.
Defective installation can result in electric shock, fire, etc.

Regarding noise

In installing work, choose a place that can fully bear the weight of the air-con-
ditioner, and where noise and vibration can be reduced.

Choose a place where cool or warm air and noise from the outdoor air outlet
of the air-conditioner does not inconvenience the neighbors.

If any alien object is placed near the outdoor air outlet of the air-conditioner,
decreased performance and increased noise can result. Avoid placing any
obstacles adjacent to the air outlet.

If the air-conditioner produces any abnormal sound, consult with your dealer.

Maintenance and inspection

If the air-conditioner is used throughout several seasons, the insides can get
dirty, reducing the performance. 

Depending upon the conditions of usage, foul odors can be generated and
drainage can deteriorate due to dust and dirt, etc.

8. Specifications

PLFY-P-NLMU-E

Notes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.

Cooling: Indoor: 26.7 °C [80 °F] DB/19.4 °C [67 °F] WB

Outdoor: 35 °C [95 °F] DB

Heating: Indoor: 21.1 °C [70 °F] DB

Outdoor: 8.3 °C [47 °F] DB/6.1 °C [43 °F] WB

*2 The operating noise is the data that was obtained in an anechoic room.
*4 The figure in ( ) indicates Panel's.

Item                                                                            Model

PLFY-P06NLMU-E

PLFY-P08NLMU-E

PLFY-P12NLMU-E

PLFY-P15NLMU-E

PLFY-P18NLMU-E

Power sourse

208/230V, 60Hz

Capacity
*1

Cooling

kW

1.8 2.3 3.5 4.4 5.3 

BTU/h

6000

8000

12000

15000

18000

Heating

kW

2.0 2.6 4.0 5.0 5.9 

BTU/h

6700

9000

13500

17000

20000

Dimension
*4

Height

mm

290 (20)

in

11-7/16 (13/16)

Width

mm

776 (1080)

946 (1250)

in

30-9/16 (42-17/32)

37-1/4 (49-7/32)

Depth

mm

634 (710)

in

24-31/32 (27-31/32)

Net weight

kg

23 (6.5)

24 (6.5)

27 (7.5)

lb

51 (15)

53 (15)

60 (17)

FAN

Airflow rate
(Low-Middle-High)

m

3

/min

6.5-8.0-9.5

6.5-8.0-9.5

6.5-8.0-9.5

7.0-8.5-10.5

9.0-11.0-12.5

cfm

230-282-335

230-282-335

230-282-335

247-300-371

318-388-441

External static 
pressure

Pa

208V

-

-

-

-

-

230V

-

-

-

-

-

Noise level 
(Low-Middle-High) *2

dB(A)

208V

27-30-33

27-30-33

27-30-33

29-33-36

31-34-37

230V

28-31-34

28-31-34

28-31-34

30-34-37

32-35-38

Filter

Standard filter

Summary of Contents for CITY MULTI PDFY-P-NMU-E Series

Page 1: ...FY P NMHU E F PFFY P NRMU E PLFY P NLMU E OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur ...

Page 2: ...et effective for 1 hr Sensor position Room temperature Airflow Fan speed Heure actuelle Programmateur Commande centralisée Programmateur arrêté OFF Indicateur du programmateur Mode de fonctionnement COOL REFROIDISSEMENT DRY DÉSHUMIDIFICA TEUR AUTO AUTOMATIQUE FAN SOUFFLERIE HEAT CHAUFF AGE Indicateur Verrouillé Régler la tempértature Mise sous tension ON Lucarne Ventilation Signe du filtre Régler ...

Page 3: ...MU E PEFY P NMHU E F PEFY P NMLU E PEFY P NMHU E PFFY P NEMU E NRMU E Filter Filtre Air Flow Flux d air A B In case of rear inlet En cas d aspiration par l arrière Filter Air Flow Filtre Flux d air Filter Air Flow Filtre Flux d air ...

Page 4: ...ing The indoor unit should be securely installed If the unit is loosely mounted it may fall causing injury 3 Remote controller Warning The remote controller should be installed in such a way that children can not play with it 4 Drain hose Caution Make sure that the drain hose is installed so that drainage can go ahead smoothly Incorrect installation may result in water leakage causing dam age to f...

Page 5: ...y refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environment 2 Names and functions of various parts Attachment and detachment of filter Fig A P 3 Caution In removing the filter precautions must be taken to protect your eyes from dust Also if you have to climb up on a stool to do the job be car...

Page 6: ...peration is stopped Approximately 1 minute after the stop of operation the indoor fan some times rotates to eliminate extra heat generated by the electric heater etc The fan speed comes to low or high Except PEFY P NMHU E F 3 3 Room temperature adjustment To change room temperature Press the A Set Temperature Button and set the room temperature of your choice Pressing or once changes the setting b...

Page 7: ...lways have filter maintenance performed by a service person Before care taking turn the power supply OFF Refer to A and B in Fig A on the page 3 for the way to remove the filter PDFY P NMU E Caution Before you start cleaning stop operation and turn OFF the power supply Remember that the fan is rotating inside at high speed posing a serious risk of injury Indoor units are equipped with filters to r...

Page 8: ...e filter is filled with dust and dirt Clean up the filter Refer to Caring for the machine There are some obstacles at the air inlet and outlet of the indoor and outdoor units Remove Windows and doors are open Close Cool air or warm air does not come out The liquid crystal dis play shows that it is in operation The restart preventing circuit is in operation for 3 min utes Wait for a while To protec...

Page 9: ...the professional engineering work required for transferring the instal lation Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can result in electric shock fire etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool or w...

Page 10: ...y 1 Cooling kW 7 0 7 9 8 8 10 6 14 1 BTU h 24000 27000 30000 36000 48000 Heating kW 7 9 8 8 10 0 11 7 15 8 BTU h 27000 30000 34000 40000 54000 Dimension Height mm 295 335 in 11 5 8 13 7 32 Width mm 1160 1510 in 45 11 16 59 15 32 Depth mm 735 775 in 28 15 16 30 17 32 Net weight kg 39 39 39 52 52 lb 86 86 86 115 115 FAN Airflow rate Low Middle2 Middle1 High m3 min 12 5 14 0 16 0 18 0 13 5 15 5 17 5 ...

Page 11: ...0 150 200 100 150 200 100 150 200 Noise level Low High 2 dB A 208V 25 32 25 32 29 36 30 38 33 40 230V 34 39 34 39 36 41 35 41 38 43 Filter Standard filter Item Model PEFY P36NMHU E PEFY P48NMHU E PEFY P54NMHU E PEFY P72NMHU E PEFY P96NMHU E Power sourse 208 230V 60Hz Capacity 1 Cooling kW 10 6 14 1 15 8 21 1 28 1 BTU h 36000 48000 54000 72000 96000 Heating kW 11 7 15 8 17 6 23 4 31 7 BTU h 40000 5...

Page 12: ... F PEFY P72NMHU E F PEFY P96NMHU E F 208V 230V 208V 230V 208V 230V 208V 230V 85 130 85 130 180 260 180 260 Model Item PFFY P06NEMU E PFFY P08NEMU E PFFY P12NEMU E PFFY P15NEMU E PFFY P18NEMU E PFFY P24NEMU E Power sourse 208 230V 60Hz Capacity 1 Cooling kW 1 8 2 3 3 5 4 4 5 3 7 0 BTU h 6000 8000 12000 15000 18000 24000 Heating kW 2 0 2 6 4 0 5 0 5 9 7 9 BTU h 6700 9000 13500 17000 20000 27000 Dime...

Page 13: ... sur une surface plane et stable dans un endroit non sujet à l accumulation de neige de feuilles ou de détritus Ne pas se tenir sur l appareil ni y déposer des objets La personne ou les objets risqueraient de tomber et de se blesser ou de blesser quelqu un Précaution L appareil extérieur doit être installé dans un endroit où l air et le bruit engendrés ne risquent pas de déranger les voisins 2 App...

Page 14: ...te d un changement de saison etc le faire fonctionner pen dant 4 à 5 heures avec la soufflerie d air jusqu à ce que l intérieur soit complètement sec Sinon de la moisissure non hygiénique et insalubre risque de se dével opper à divers endroits de la pièce Si l alimentation est gardée sous ten sion cela risque de gaspiller plusieurs watts voire des dizaines de watts et l accumulation de poussière e...

Page 15: ...ant le fonctionnement en mode dégivrage STAND BY ATTENTE S affiche entre le début du fonctionnement en mode chauffage et le moment où de l air chaud est soufflé dans la pièce Précautions Lorsque le climatiseur est utilisé en même temps que des brûleurs ven tiler convenablement la pièce Une ventilation insuffisante risque de pro voquer des accidents à la suite d un manque d oxygène Ne jamais placer...

Page 16: ...ortie sauf en cas de nécessité absolue Aérer occasionnellement la pièce Sauf le modèle PEFY P NMHU E F Étant donné que l air est régulièrement vicié lorsqu une pièce reste fermée pendant une longue période il est parfois nécessaire d aérer la pièce Pren dre des précautions particulières lorsque des appareils à gaz sont utilisés en même temps que le climatiseur Si l appareil de ventilation LOSSNAY ...

Page 17: ...ntrée sur l affichage à cristaux liquides se reporter à Réglage de la température de la pièce et faire fonctionner la touche de réglage Le filtre est encombré de poussière et de crasse Nettoyer le filtre Se reporter à Entretien de l appareil Des obstacles bloquent l arrivée et la sortie d air des appareils intérieurs et extérieurs Retirer les obstacles Des fenêtres et des portes sont ouvertes Ferm...

Page 18: ...utilisant impérativement des circuits exclusifs L utili sation d autres appareils sur la même source d alimentation peut faire sauter les coupe circuits et griller les fusibles Ne jamais raccorder le câble de mise à la terre à une conduite de gaz une conduite d eau à un paratonnerre ou à un câble de mise à la terre de ligne téléphonique Pour plus de détails consulter le revendeur Dans certains typ...

Page 19: ...5 8 Largeur mm 710 960 in 27 31 32 37 13 16 Profondeur mm 735 in 28 15 16 Poids net kg 26 26 27 32 34 lb 57 57 60 71 75 VENTILA TEUR Débit de l air Faible Moyen2 Moyen1 Haut m3 min 6 0 6 5 7 5 8 5 6 0 6 5 7 5 8 5 6 0 6 5 7 5 8 5 10 0 11 0 12 5 14 0 10 0 11 0 12 5 14 0 cfm 211 229 264 300 211 229 264 300 211 229 264 300 353 388 441 494 353 388 441 494 Pression statique externe 3 Pa 208V 30 50 80 30...

Page 20: ...m 380 in 14 31 32 Largeur mm 750 1000 in 29 17 32 39 3 8 Profondeur mm 900 in 35 7 16 Poids net kg 44 45 50 lb 98 100 111 VENTILA TEUR Débit de l air Faible Haut m3 min 10 0 14 0 10 0 14 0 13 5 19 0 15 5 22 0 18 0 25 0 cfm 353 494 353 494 477 671 547 777 636 883 Pression statique externe 3 Pa 208V 50 160 50 160 50 160 50 160 50 160 230V 100 150 200 100 150 200 100 150 200 100 150 200 100 150 200 N...

Page 21: ...2NMHU E F PEFY P96NMHU E F Source d alimentation 208 230V 60Hz Capacité 1 Refroidissement kW 8 8 15 8 21 1 28 1 BTU h 30000 54000 72000 96000 Chauffage kW 8 4 14 9 19 9 26 4 BTU h 28500 51000 68000 90000 Dimensions Hauteur mm 380 470 in 14 31 32 18 17 32 Largeur mm 1000 1200 1250 in 39 3 8 47 1 4 49 7 32 Profondeur mm 900 1120 in 35 7 16 44 1 8 Poids net kg 50 70 100 lb 111 155 221 VENTILA TEUR Dé...

Page 22: ...VENTILA TEUR Débit de l air Faible Haut m3 min 5 5 6 5 5 5 6 5 7 0 9 0 8 5 11 0 10 0 13 0 10 0 14 0 cfm 194 229 194 229 247 317 300 388 353 459 353 494 Pression statique externe Pa 208V 230V Niveau de bruit Faible Haut 2 dB A 208V 36 41 36 41 37 41 38 43 38 43 40 46 230V 36 41 36 41 37 41 38 43 38 43 40 46 Filtre Filtre standard Élément Modèle PFFY P06NRMU E PFFY P08NRMU E PFFY P12NRMU E PFFY P15N...

Page 23: ...OKYO 100 8310 JAPAN This product is designed and intended for use in the residential commer cial and light industrial environment Please be sure to put the contact address telephone number on this manual before handing it to the customer Printed in Japan WT04561X01 ...

Reviews: