34
5. ABOUT THE MONITOR FUNCTION
The monitor function allows the receiving status (RC, R1, R2, R3)
indicated by the operation indicator LEDs of the AJ65BT-RPI-10A/10B
to be monitored (imported to the master station). To use the monitor
function, the station numbers must be set and parameter setting to the
master station must also be made as remote I/O stations. For the way to
make parameter setting, refer to the user's manual of the master
module used.
Also, the imported receiving status of the mating module can be
indicated by the "SC, S1, S2, S3" operation indicator LEDs of the own
module using the sequence program of the master station, ensuring
ease of optical axis adjustment. Refer to Section 3.5 for the I/O signals
transferred to/from the master module.
POINT
• Make fine adjustment of the optical axes by adjusting the orientation of the
own module until the receiving status of the mating module is maximized.
Using the monitor function allows the receiving status of the mating module to
be checked on the own module, ensuring ease of fine adjustment of the optical
axes.
• Since the monitor function transmits the receiving status through CC-Link data
link, the modules must at least be ready to receive lights (the "RC" operation
indicator LEDs are lit) each other.