323
Parameter clear
4
4.25 Parameter clear
POINT
· Set "1" in
Pr. CL parameter
clear
to initialize parameters. (Parameters are not cleared when "1" is set in
Pr. 77
Parameter write selection
. In addition, calibration parameters are not cleared.)
Setting
Description
0
Not executed.
1
Returns all parameters to the initial values except for
calibration parameters, terminal function selection
parameters, etc
.
Refer to the list of parameters on
page 390
for availability of parameter clear.
and
are displayed alternately ... Why?
The inverter is not in the PU operation mode.
1. Press .
is lit and the monitor (4 digit LED) displays "0" (
Pr. 79
= "0" (initial value)).
2. Carry out operation from step 6 again.
1.
Screen at powering ON
The monitor display appears.
Display
Operation
3.
Press to choose the parameter
setting mode.
Flicker ··· Parameter setting complete!!
7.
Press to set.
5.
Press to read the present set value.
" "(initial value) appears.
PU indication is lit.
2.
Press to choose the PU operation
mode.
· Turn to read another parameter.
· Press twice to show the next parameter.
· Press to show the setting again.
4.
Turn until " " (parameter clear)
appears.
6.
Turn to change it to
the setting value " ".
The parameter
number read
previously appears.