14-321
14-321
14.5.3. Current
Data concerning the electrical current value of each axis motor can be monitored.
The following data can be monitored.
-
Current cmd
The current command of the motor is displayed.
-
Max. current cmd1
The maximum value of the current command after robot controller power supply is turned on is displayed.
-
Max. current cmd2
The maximum value of the current command for the last 2 seconds is displayed.
-
Current feedback
A present value of the motor current is displayed.
-
Tolerable cmd-/+
The limit value of the minus side and the plus side of the current command set to the motor is displayed.
-
RMS current
Present RMS value of the motor current is displayed.
Click [Reset] button to reset all Servo Monitor.
Figure 14-52 Servo monitor - Current
Summary of Contents for 3F-14C-WINE
Page 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Page 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Page 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Page 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Page 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Page 624: ...24 624 24 624 Figure 24 4 Document output example ...