14.2.6.4. Record information
The record of errors that have occurred in the past can be referred to.
You can check the error record in the robot controller for each error level (high level, low level, caution). You can
also save the error record to a file.
Controller software versions that allow use of the error record function are as follows.
Controller
S/W Ver. of the controller
CR800-D/CR800-R/CR800-Q
All versions
CR750-D/CRnD-700
Ver.S1j or later
CR750-Q/CRnQ-700
Ver.R1j or later
Click the [Record] button. Select the level to reference and click the [OK] button.
Figure 14-21 Record Information Error Level Setting
Figure 14-22 Error record
This display is not constantly displayed. To refresh the information, click the [Refresh] button.
Timing from which error information is registered in the error
record
When you reset an error, the error information is registered in the robot controller's error record file.
Note that an occurring error is not registered in error record when the power supply is turned off