Operation | 42
Access via Telnet
The unit may be accessed via Telnet. There is no special protocol on the Telnet channel; the unit will expect the same
commands, and offer the same replies, as via the serial port (see Page 21).
Telnet access must first be enabled on the MISC web page. If not being used, it is recommended that it be left disabled for
security reasons.
When a Telnet connection is established, the Converter will request the password, which should be sent in the standard
MITEQ wrapper (‘{‘<address byte (ignored)><password>’}’<checksum byte>). The default password is five numerical ones
and can be type in as:
{{11111}}
Figure 3-29. Opening Telnet Port
Figure 3-30. Telnet Communications
Once the connection is established, standard serial commands may be sent and responses will be received. Logout is
automatic when the Telnet connection is broken. The password must be sent to the unit again to re-establish connection.