TA7104 /7108 Hardware Installation
155/1531-ANF 90114 C 2017-03-08
17
2.
Change the TA7104/7108 system management network interface to something other than Rescue
as described in the
Software Configuration Guide
, Chapter
Miscellaneous
– Management
Interface
, Section
Management Interface Configuration
. Note that you must be able to contact the
interface you select in order to continue with the following steps.
3.
Contact the TA7104/7108 through the new system management network interface.
4.
Disable the
Rescue
network interface as described in the
Software Configuration Guide
, Chapter
Interface Parameters
, Section
Interfaces Configuration
.
Factory Reset
The Factory reset reverts the TA7104/7108 back to its default factory settings. It deletes the persistent
MIB values of the unit, including:
The firmware pack download configuration files.
The SNMP configuration, including the SNMPv3 passwords and users.
The PPPoE configuration, including the PPP user names and passwords.
The Factory reset creates a new configuration file with the default factory values. It should be
performed with the TA7104/7108 connected to a network with access to a DHCP server. If the unit
cannot find a DHCP server, it sends requests indefinitely.
To trigger the Factory Reset:
1.
Power the TA7104/7108 off.
2.
Insert a small, unbent paper clip into the
Reset / Default
hole located at the rear of the
TA7104/7108. While pressing the
Reset / Default
button, restart the unit. Do not depress before
the LEDs stop blinking and are steadily ON.
3.
Release the paper clip. The TA7104/7108 restarts. This procedure resets all variables in the MIB
modules to their default value. When the TA7104/7108 has finished its provisioning sequence, it is
ready to be used with a DHCP-provided IP address and MIB parameters. This procedure can also
be performed at run-time.
Note:
The Factory reset alters any persistent configuration data of the TA7104/7108.
4.4
MANAGEMENT CHOICES
Congratulations for properly installing the TA7104/7108. You can now configure the software
parameters of the unit.
The TA7104/7108 offers various management options. All these options are described in the
Dgw v2.0
Software Configuration Guide
.
Table 8:
Management Options
Management Choice
Features
Web GUI
The TA7104/7108 web interface allows you to configure the following
information:
•
Network attributes
•
SIP parameters
•
VoIP settings
•
Management settings such as configuration scripts, restore /
backup, etc.
SNMPv1/2/3
The TA7104/7108 SNMP feature allows you to configure all the MIB
services.
Command Line
Interface (CLI)
The TA7104/7108 CLI feature allows you to configure all the MIB
services.
Unit Manager
Network
The UMN offers the following:
•
Auto-discovery
•
Group provisioning
•
SNMP access and remote management.