TA7104 /7108 Hardware Installation
155/1531-ANF 90114 C 2017-03-08
14
4.2
INDICATORS (LEDS)
The indicators (LEDs) of the TA7104/7108 are described in
TA7104/7108 Connectors and
Indicators.
LED Patterns
– Specific Conditions
Table 5 describes the different states a Mitel unit can have and their associated LED patterns.
Table 5:
LED Patterns
CondiAction
Description
LED Pattern
RestartPending
Triggered when the
RESET/DEFAULT
button is pressed in the
ResetPending
state. The unit prepares for a physical
shutdown and restart.
Power
LED:
•
blinking, 1Hz, 50%
duty
All other LEDs:
•
OFF
RecoveryPending
Triggered when the
RESET/DEFAULT
button is pressed at start-time or for at
least 7 seconds.
All LEDs:
•
blinking, 1Hz, 50%
duty
DefaultSettingsPendin g
Triggered when the
RESET/DEFAULT
button is not released while in
ResetPending
state.
At run time, if the
RESET/DEFAULT
button
is released within 5 seconds, the unit
applies default settings, otherwise the
action is cancelled and the unit goes back
to the operation mode state or it resets.
At start time, the unit stays in this state
until the
RESET/DEFAULT
button is
released. The unit then applies the default
settings and restarts.
All LEDs:
•
steady ON
UpdateInProgress
A firmware pack is downloaded into the
unit and written to persistent storage.
All LEDs:
•
cycling from left to
right, individually blinking
1Hz, 33% duty
UpdateFailed
Triggered after a failure of a firmware pack
download operation. After 4 seconds, the
unit restarts.
All LEDs:
•
blinking at 3Hz,
50% duty. One LED out of
two has a 180 degree
phase. This pattern lasts for
8 seconds.
Rescue Network
Enabled
Triggered after the user has performed a
partial reset procedure.
Power
and
In Use
LEDs:
•
blinking
(synchronized)
1Hz, 75% duty
BootOnRecoveryBank
Triggered when the unit is booting on the
recovery bank and no update is pending.
Power LED:
•
blinking, 0.25Hz,
75% duty
Automatic network
configuration in progress
Waiting for DHCP (IPv4 or IPv6) answer or
IPv6 router advertisement or PPPoE
connection.
All LEDs:
•
Blinking green,
3Hz, 50% duty